Repeatability, Reproducibility, and Accuracy of Quantitative MRI of the Breast in the Community Radiology Setting

被引:28
作者
Sorace, Anna G. [1 ,2 ,3 ]
Wu, Chengyue [3 ]
Barnes, Stephanie L. [3 ,4 ]
Jarrett, Angela M. [4 ]
Avery, Sarah [5 ]
Patt, Debra [6 ]
Goodgame, Boone [7 ,8 ]
Luci, Jeffery J. [3 ,9 ]
Kang, Hakmook [10 ]
Abramson, Richard G. [11 ]
Yankeelov, Thomas E. [1 ,2 ,3 ,4 ]
Virostko, John [1 ,2 ]
机构
[1] Univ Texas Austin, Dept Diagnost Med, Austin, TX 78712 USA
[2] Univ Texas Austin, Livestrong Canc Inst, Austin, TX 78712 USA
[3] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[4] Univ Texas Austin, Inst Computat Engn & Sci, Austin, TX 78712 USA
[5] Austin Radiol Assoc, Austin, TX USA
[6] Texas Oncol, Austin, TX USA
[7] Seton Hosp, Austin, TX USA
[8] Univ Texas Austin, Dept Internal Med, Austin, TX 78712 USA
[9] Univ Texas Austin, Dept Neurosci, Austin, TX 78712 USA
[10] Vanderbilt Univ, Med Ctr, Dept Biostat, Nashville, TN USA
[11] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN USA
关键词
APPARENT DIFFUSION-COEFFICIENT; ICE-WATER PHANTOM; NEOADJUVANT CHEMOTHERAPY; PATHOLOGICAL RESPONSE; MENSTRUAL-CYCLE; CLINICAL-TRIALS; DCE-MRI; T; CANCER; THERAPY;
D O I
10.1002/jmri.26011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Quantitative diffusion-weighted MRI (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) have the potential to impact patient care by providing noninvasive biological information in breast cancer. Purpose/Hypothesis: To quantify the repeatability, reproducibility, and accuracy of apparent diffusion coefficient (ADC) and T1-mapping of the breast in community radiology practices. Study Type: Prospective. Subjects/Phantom: Ice-water DW-MRI and T1 gel phantoms were used to assess accuracy. Normal subjects (n53) and phantoms across three sites (one academic, two community) were used to assess reproducibility. Test-retest analysis at one site in normal subjects (n512) was used to assess repeatability. Field Strength/Sequence: 3T Siemens Skyra MRI quantitative DW-MRI and T1-mapping. Assessment: Quantitative DW-MRI and T1-mapping parametric maps of phantoms and fibroglandular and adipose tissue of the breast. Statistical Tests: Average values of breast tissue were quantified and Bland-Altman analysis was performed to assess the repeatability of the MRI techniques, while the Friedman test assessed reproducibility. Results: ADC measurements were reproducible across sites, with an average difference of 1.6% in an ice-water phantom and 7.0% in breast fibroglandular tissue. T1 measurements in gel phantoms had an average difference of 2.8% across three sites, whereas breast fibroglandular and adipose tissue had 8.4% and 7.5% average differences, respectively. In the repeatability study, we found no bias between first and second scanning sessions (P50.1). The difference between repeated measurements was independent of the mean for each MRI metric (P50.156, P50.862, P50.197 for ADC, T1 of fibroglandular tissue, and T1 of adipose tissue, respectively). Data Conclusion: Community radiology practices can perform repeatable, reproducible, and accurate quantitative T1mapping and DW-MRI. This has the potential to dramatically expand the number of sites that can participate in multisite clinical trials and increase clinical translation of quantitative MRI techniques for cancer response assessment. Level of Evidence: 1 Technical Efficacy: Stage 2
引用
收藏
页码:695 / 707
页数:13
相关论文
共 50 条
  • [41] Quantitative metrics in clinical radiology reporting: a snapshot perspective from a single mixed academic-community practice
    Abramson, Richard G.
    Su, Pei-Fang
    Shyr, Yu
    MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1357 - 1366
  • [42] The accuracy of breast MRI radiomic methodologies in predicting pathological complete response to neoadjuvant chemotherapy: A systematic review and network meta-analysis
    O'Donnell, J. P. M.
    Gasior, S. A.
    Davey, M. G.
    O'Malley, E.
    Lowery, A. J.
    McGarry, J.
    O'Connell, A. M.
    Kerin, M. J.
    McCarthy, P.
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 157
  • [43] Accuracy of MRI volume measurements of breast lesions: comparison between automated, semiautomated and manual assessment
    Rominger, Marga B.
    Fournell, Daphne
    Nadar, Beenarose Thanka
    Behrens, Sarah N. M.
    Figiel, Jens H.
    Keil, Boris
    Heverhagen, Johannes T.
    EUROPEAN RADIOLOGY, 2009, 19 (05) : 1097 - 1107
  • [44] Accuracy of MRI Versus PET/CT in the Prediction of Treatment Response to Neoadjuvant Chemotherapy in Breast Cancer
    Alshaibani, Noof
    Chandramohan, Janaki Krithika
    Althawadi, Yusuf
    Almusalam, Maryam
    Khairi, Sara S.
    Saif, Hamad S.
    Al Sindi, Khalid
    Aly, Salwa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [45] Diagnostic accuracy of MRI textural analysis in the classification of breast tumors
    Brown, Ann L.
    Jeong, Joanna
    Wahab, Rifat A.
    Zhang, Bin
    Mahoney, Mary C.
    CLINICAL IMAGING, 2021, 77 : 86 - 91
  • [46] Co-registration of MRI and ultrasound: accuracy of targeting based on radiology-pathology correlation
    Lai, Win Shun
    Zarzour, Jessica G.
    Gordetsky, Jennifer B.
    Rais-Bahrami, Soroush
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2017, 6 (03) : 406 - 412
  • [47] Reproducibility of dynamic contrast-enhanced MRI in human muscle and tumours: comparison of quantitative and semi-quantitative analysis
    Galbraith, SM
    Lodge, MA
    Taylor, NJ
    Rustin, GJS
    Bentzen, S
    Stirling, JJ
    Padhani, AR
    NMR IN BIOMEDICINE, 2002, 15 (02) : 132 - 142
  • [48] Breast MRI for Evaluating Residual Tumor Size Following Neoadjuvant Chemotherapy: Clinicopathologic Factors and MRI Imaging Features Affecting its Accuracy
    Park, Jin Young
    Kim, Young Seon
    Lee, Seung Eun
    CURRENT MEDICAL IMAGING, 2022, 18 (08) : 876 - 882
  • [49] Multi-center evaluation of stability and reproducibility of quantitative MRI measures in healthy calf muscles
    Schlaffke, Lara
    Rehmann, Robert
    Rohm, Marlena
    Otto, Louise A. M.
    de Luca, Alberto
    Burakiewicz, Jedrzej
    Baligand, Celine
    Monte, Jithsa
    den Harder, Chiel
    Hooijmans, Melissa T.
    Nederveen, Aart
    Schlaeger, Sarah
    Weidlich, Dominik
    Karampinos, Dimitrios C.
    Stouge, Anders
    Vaeggemose, Michael
    D'Angelo, Maria Grazia
    Arrigoni, Filippo
    Kan, Hermien E.
    Froeling, Martijn
    NMR IN BIOMEDICINE, 2019, 32 (09)
  • [50] A novel framework for evaluating the image accuracy of dynamic MRI and the application on accelerated breast DCE MRI
    Yuan Le
    Marcel Dominik Nickel
    Stephan Kannengiesser
    Berthold Kiefer
    Bruce Spottiswoode
    Brian Dale
    Victor Soon
    Chen Lin
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 309 - 320