Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18 MV photon beam: Determination of initial electron beam parameters

被引:4
作者
Najafzadeh, Milad [1 ]
Hoseini-Ghafarokhi, Mojtaba [2 ]
Bolagh, Rezgar Shahi Mayn [3 ]
Haghparast, Mohammad [1 ]
Zarifi, Shiva [4 ]
Nickfarjam, Abolfazl [5 ]
Farhood, Bagher [6 ]
Chow, James C. L. [7 ,8 ]
机构
[1] Hormozgan Univ Med Sci, Fac Med, Dept Radiol, Bandare Abbas, Iran
[2] Kermanshah Univ Med Sci, Sch Med Sci, Dept Radiol & Nucl Med, Kermanshah, Iran
[3] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[4] Semnan Univ Med Sci, Fac Med, Dept Med Phys, Semnan, Iran
[5] Shahid Sadoughi Univ Med Sci, Fac Med, Dept Med Phys, Yazd, Iran
[6] Kashan Univ Med Sci, Fac Paramed Sci, Dept Med Phys & Radiol, Kashan, Iran
[7] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[8] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
关键词
Radiotherapy; Monte Carlo simulation; benchmarking; Siemens Oncor; gamma analysis; DOSE DISTRIBUTIONS; RADIOTHERAPY; SENSITIVITY; SIMULATION; INCIDENT; ENERGY; DISCREPANCIES; FLUENCE; SPECTRA; IMPROVE;
D O I
10.3233/XST-190568
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to benchmark a Monte Carlo (MC) model of the 18MV photon beam produced by the Siemens Oncor (R) linac using the BEAMnrc and DOSXYZnrc codes. METHODS: By matching the percentage depth doses and beam profiles calculated by MC simulations with measurements, the initial electron beam parameters including electron energy, full width at half maximum (spatial FWHM), and mean angular spread were derived for the 10 x 10 cm(2) and 20 x 20 cm(2) field sizes. The MC model of the 18MV photon beam was then validated against the measurements for different field sizes (5 x 5, 30 x 30 and 40 x 40 cm(2)) by gamma index analysis. RESULTS: The optimum values for electron energy, spatial FWHM and mean angular spread were 14.2MeV, 0.08cm and 0.8 degree, respectively. The MC simulations yielded the comparable measurement results of these optimum parameters. The gamma passing rates (with acceptance criteria of 1%/1 mm) for percentage depth doses were found to be 100% for all field sizes. For cross-line profiles, the gamma passing rates were 100%, 97%, 95%, 96% and 95% for 5 x 5, 10 x 10, 20 x 20, 30 x 30 and 40 x 40 cm(2) field sizes, respectively. CONCLUSIONS: By validation of the MC model of Siemens Oncor (R) linac using various field sizes, it was found that both dose profiles of small and large field sizes were very sensitive to the changes in spatial FWHM and mean angular spread of the primary electron beam from the bending magnet. Hence, it is recommended that both small and large field sizes of the 18MV photon beams should be considered in the Monte Carlo linac modeling.
引用
收藏
页码:1047 / 1070
页数:24
相关论文
共 47 条
  • [1] Determination of the initial beam parameters in Monte Carlo linac simulation
    Aljarrah, K
    Sharp, GC
    Neicu, T
    Jiang, SB
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 850 - 858
  • [2] Monte Carlo linear accelerator simulation of megavoltage photon beams: Independent determination of initial beam parameters
    Almberg, Sigrun Saur
    Frengen, Jomar
    Kylling, Arve
    Lindmo, Tore
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 40 - 47
  • [3] [Anonymous], 2018, 1D 2D 3D GAMMA COMPU
  • [4] [Anonymous], 2000, 398 TIAEA VIENN INT
  • [5] Monte Carlo evaluation of the potential benefits of flattening filter free beams from the Oncor® clinical linear accelerator
    Asadi, Amin
    Razavi-Ratki, Seid Kazem
    Jabbari, Keyvan
    Najafzadeh, Milad
    Nickfarjam, Abolfazl
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (02) : 281 - 302
  • [6] GENOMIC INSTABILITY IN CANCER Strategies to improve radiotherapy with targeted drugs
    Begg, Adrian C.
    Stewart, Fiona A.
    Vens, Conchita
    [J]. NATURE REVIEWS CANCER, 2011, 11 (04) : 239 - 253
  • [7] Determining optimization of the initial parameters in Monte Carlo simulation for linear accelerator radiotherapy
    Chang, Kwo-Ping
    Wang, Zhi-Wei
    Shiau, An-Cheng
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 161 - 165
  • [8] Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
    Chetty, Indrin J.
    Curran, Bruce
    Cygler, Joanna E.
    DeMarco, John J.
    Ezzell, Gary
    Faddegon, Bruce A.
    Kawrakow, Iwan
    Keall, Paul J.
    Liu, Helen
    Ma, C. -M. Charlie
    Rogers, D. W. O.
    Seuntjens, Jan
    Sheikh-Bagheri, Daryoush
    Siebers, Jeffrey V.
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4818 - 4853
  • [9] On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV Varian photon beam
    Chibani, Omar
    Ma, C. -M. Charlie
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1206 - 1216
  • [10] On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters
    Chibani, Omar
    Moftah, Belal
    Ma, C. -M. Charlie
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 188 - 201