Impact of biplane versus single-plane imaging on radiation dose, contrast load and procedural time in coronary angioplasty

被引:33
作者
Sadick, V. [1 ,2 ]
Reed, W.
Collins, L.
Sadick, N. [3 ]
Heard, R. [4 ]
Robinson, J.
机构
[1] Westmead Hosp, Dept Radiol, Sydney, NSW, Australia
[2] Univ Sydney, Fac Hlth Sci, Discipline Med Radiat Sci, Sydney, NSW 2006, Australia
[3] Westmead Hosp, Dept Cardiol, Sydney, NSW, Australia
[4] Univ Sydney, Fac Hlth Sci, Discipline Behav & Social Sci Hlth, Sydney, NSW 2006, Australia
关键词
INDUCED NEPHROPATHY; INTERVENTIONAL CARDIOLOGY; CARDIAC-CATHETERIZATION; AMORPHOUS-SILICON; PATIENT; EXPOSURE; RISK; AREA; RECOMMENDATIONS; OPTIMIZATION;
D O I
10.1259/bjr/21696839
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Coronary angioplasties can be performed with either single-plane or biplane imaging techniques. The aim of this study was to determine whether biplane imaging, in comparison to single-plane imaging, reduces radiation dose and contrast load and shortens procedural time during (i) primary and elective coronary angioplasty procedures, (ii) angioplasty to the main vascular territories and (iii) procedures performed by operators with various levels of experience. This prospective observational study included a total of 504 primary and elective single-vessel coronary angioplasty procedures utilising either biplane or single-plane imaging. Radiographic and clinical parameters were collected from clinical reports and examination protocols. Radiation dose was measured by a dose-area-product (DAP) meter intrinsic to the angiography system. Our results showed that biplane imaging delivered a significantly greater radiation dose (181.4+/-121.0 Gycm(2)) than single-plane imaging (133.6+/-92.8 Gycm(2), p < 0.0001). The difference was independent of case type (primary or elective) (p=0.862), vascular territory (p=0.519) and operator experience (p=0.903). No significant difference was found in contrast load between biplane (166.8+/-62.9 ml) and single-plane imaging (176.8+/-66.0 ml) (p=0.302). This non-significant difference was independent of case type (p=0.551), vascular territory (p=0.308) and operator experience (p=0.304). Procedures performed with biplane imaging were significantly longer (55.3+/-27.8 min) than those with single-plane (48.9+/-24.2 min, p=0.010) and, similarly, were not dependent on case type (p=0.226), vascular territory (p=0.642) or operator experience (p=0.094). Biplane imaging resulted in a greater radiation dose and a longer procedural time and delivered a non-significant reduction in contrast load than single-plane imaging. These findings did not support the commonly perceived advantages of using biplane imaging in single-vessel coronary interventional procedures.
引用
收藏
页码:379 / 393
页数:15
相关论文
共 55 条
[31]   Contrast-induced acute kidney injury [J].
McCullough, Peter A. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (15) :1419-1428
[32]   Epidemiology and prognostic implications of contrast-induced nephropathy [J].
McCullough, Peter A. ;
Adam, Andy ;
Becker, Christoph R. ;
Davidson, Charles ;
Lameire, Norbert ;
Stacul, Fulvio ;
Tumlin, James .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (6A) :5K-13K
[33]   The role of cardiac catheterization in adult congenital heart disease [J].
McLaughlin, Peter ;
Benson, Lee ;
Horlick, Eric .
CARDIOLOGY CLINICS, 2006, 24 (04) :531-+
[34]   An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures [J].
Morrish, W. E. ;
Goldstone, K. E. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (961) :35-45
[35]  
MURPHY KR, 1998, STAT POWER ANAL, P31
[36]   Preliminary reference levels in interventional cardiology [J].
Neofotistou, V ;
Vano, E ;
Padovani, R ;
Kotre, J ;
Dowling, A ;
Toivonen, M ;
Kottou, S ;
Tsapaki, V ;
Willis, S ;
Bernardi, G ;
Faulkner, K .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2259-2263
[37]   Reference levels in PTCA as a function of procedure complexity [J].
Peterzol, A ;
Quai, E ;
Padovani, R ;
Bernardi, G ;
Kotre, CJ ;
Dowling, A .
RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) :54-58
[38]  
*PHIL MED, 2008, BIPL CARD XRAY SYST
[39]  
PORTNOY LG, 2009, FDN CLIN RES, P483
[40]   Radiation exposure during elective coronary angioplasty: The effect of flat-panel detection [J].
Prasan, Ananth M. ;
Ison, Glen ;
Rad, Dip Med ;
Rees, David M. .
HEART LUNG AND CIRCULATION, 2008, 17 (03) :215-219