Performance of nanoflow liquid chromatography using core-shell particles: A comparison study

被引:9
|
作者
Liu, Ya [1 ,2 ]
Sun, Kaiyue [1 ,2 ]
Shao, Chuyi [1 ,2 ]
Shi, Xiaohui [1 ,2 ]
Zeng, Juxing [1 ,2 ]
Guo, Rui [3 ]
Zhang, Bo [1 ,2 ]
机构
[1] Xiamen Univ, Coll Chem & Chem Engn, Dept Chem, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Coll Chem & Chem Engn, MOE Key Lab Spectrochem Anal & Instrumentat, Xiamen 361005, Peoples R China
[3] ColumnScientific Inc, Xiamen 361102, Peoples R China
基金
中国国家自然科学基金;
关键词
Core-shell particle; Superficially porous particle; Nanoflow liquid chromatography; Single particle frit; Capillary column technology; Proteomics; CHIRAL STATIONARY PHASES; NARROW-BORE COLUMNS; CAPILLARY COLUMNS; PEAK-CAPACITY; KINETIC PERFORMANCE; FLOW; FRITS; ELECTROCHROMATOGRAPHY; SEPARATIONS; SELECTOR;
D O I
10.1016/j.chroma.2021.462218
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Due to its unique structure, core-shell material has presented significantly improved chromatographic performance in comparison with conventional totally porous material. This has been well demonstrated in the analytical column format, e.g. 4.6 mm i.d. columns. In the proteomics field, there is always a demand for high resolution microseparation tools. In order to explore core-shell material's potential in proteomics-oriented microseparations, we investigated chromatographic performance of core-shell material in a nanoLC format, as well as its resolving power for protein digests. The results show core-shell nanoLC columns have similar van Deemter curves to the totally porous particle-packed nanoLC columns. For 100 mu m i.d. capillary columns, the core-shell material does not have significantly better dynamics. However, both core-shell and totally porous particle-packed nanoLC columns have shown high efficiencies: plate heights of similar to 11 mu m, equivalent to 90000 plates per meter, have been achieved with 5 mu m particles. Using a 60 cm long core-shell nanoLC column, 720 00 plates were realized in an isocratic separation of neutral compounds. For a 15 cm long nanoLC column, a maximum peak capacity of 220 has been achieved in a 5 hour gradient separation of protein digests, indicating the high resolving power of core-shell nanoLC columns. With a standard HeLa cell lysate as the sample, 2546 proteins were identified by using the core-shell nanoLC column, while 2916 proteins were identified by using the totally porous particle-packed nanoLC column. Comparing the two sets of proteomics data, it was found that 1830 proteins were identified by both columns, while 1086 and 716 proteins were uniquely identified by using totally porous and core-shell particle-packed nanoLC columns, respectively, suggesting their complementarity in nanoLC-MS based proteomics. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Fabrication of core-shell particles for a fluidized bed electrode in seawater desalination
    Kim, Eun-Hee
    Jung, Yeon-Gil
    Lee, Je-Hyun
    Yeo, Jeong-Gu
    Yang, Seung-Cheol
    Choi, Jiyeon
    SURFACE & COATINGS TECHNOLOGY, 2014, 260 : 424 - 428
  • [32] New Trend in the LC Separation Analysis of Pharmaceuticals - High Performance Separation by Ultra High-performance Liquid Chromatography (UHPLC) with Core-shell Particle CB Columns
    Nishi, Hiroyuki
    Nagamatsu, Kumi
    ANALYTICAL SCIENCES, 2014, 30 (02) : 205 - 211
  • [33] Comparison of heat friction effects in narrow-bore columns packed with core-shell and totally porous particles
    Gritti, Fabrice
    Guiochon, Georges
    CHEMICAL ENGINEERING SCIENCE, 2010, 65 (23) : 6310 - 6319
  • [34] Reducing Iridium Loading in Oxygen Evolution Reaction Electrocatalysts Using Core-Shell Particles with Nitride Cores
    Tackett, Brian M.
    Sheng, Wenchao
    Kattel, Shyam
    Yao, Siyu
    Yan, Binhang
    Kuttiyiel, Kurian A.
    Wu, Qiyuan
    Chen, Jingguang G.
    ACS CATALYSIS, 2018, 8 (03): : 2615 - +
  • [35] Development and analytical comparison of microflow and nanoflow liquid chromatography/mass spectrometry procedures for quantification of cardiac troponin T in mouse hearts
    Olkowicz, Mariola
    Rybakowska, Iwona
    Chlopicki, Stefan
    Smolenski, Ryszard T.
    TALANTA, 2015, 131 : 510 - 520
  • [36] Rheological behavior and microstructure of bimodal suspensions of core-shell structured swollen particles
    Nakamura, Hiroshi
    Tachi, Kazuyuki
    JOURNAL OF APPLIED POLYMER SCIENCE, 2006, 102 (03) : 2212 - 2217
  • [37] Effects of hydrophobic interactions on swelling of carboxylated core-shell structured latex particles
    Nakamura, H
    Tachi, K
    JOURNAL OF APPLIED POLYMER SCIENCE, 1997, 65 (10) : 1933 - 1938
  • [38] Dynamics of shear-thinning suspensions of core-shell structured latex particles
    Nakamura, H
    Tachi, K
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2006, 297 (01) : 312 - 316
  • [39] Thermal Performance Testing of a Solar Water Heating System Using Core-Shell Structured Nanofluids
    Atmaca, Ibrahim
    Ozdemir, Osman Samet
    Caglar, Ahmet
    Soylu, Sezgi Kocak
    Asilturk, Meltem
    NANOSCALE AND MICROSCALE THERMOPHYSICAL ENGINEERING, 2022, 26 (04) : 218 - 241
  • [40] Comparison of a new high-resolution monolithic column with core-shell and fully porous columns for the analysis of retinol and α-tocopherol in human serum and breast milk by ultra-high-performance liquid chromatography
    Kucerova, Barbora
    Krcmova, Lenka
    Solichova, Dagmar
    Plisek, Jiri
    Solich, Petr
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (14) : 2223 - 2230