Performance of nanoflow liquid chromatography using core-shell particles: A comparison study

被引:9
|
作者
Liu, Ya [1 ,2 ]
Sun, Kaiyue [1 ,2 ]
Shao, Chuyi [1 ,2 ]
Shi, Xiaohui [1 ,2 ]
Zeng, Juxing [1 ,2 ]
Guo, Rui [3 ]
Zhang, Bo [1 ,2 ]
机构
[1] Xiamen Univ, Coll Chem & Chem Engn, Dept Chem, Xiamen 361005, Peoples R China
[2] Xiamen Univ, Coll Chem & Chem Engn, MOE Key Lab Spectrochem Anal & Instrumentat, Xiamen 361005, Peoples R China
[3] ColumnScientific Inc, Xiamen 361102, Peoples R China
基金
中国国家自然科学基金;
关键词
Core-shell particle; Superficially porous particle; Nanoflow liquid chromatography; Single particle frit; Capillary column technology; Proteomics; CHIRAL STATIONARY PHASES; NARROW-BORE COLUMNS; CAPILLARY COLUMNS; PEAK-CAPACITY; KINETIC PERFORMANCE; FLOW; FRITS; ELECTROCHROMATOGRAPHY; SEPARATIONS; SELECTOR;
D O I
10.1016/j.chroma.2021.462218
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Due to its unique structure, core-shell material has presented significantly improved chromatographic performance in comparison with conventional totally porous material. This has been well demonstrated in the analytical column format, e.g. 4.6 mm i.d. columns. In the proteomics field, there is always a demand for high resolution microseparation tools. In order to explore core-shell material's potential in proteomics-oriented microseparations, we investigated chromatographic performance of core-shell material in a nanoLC format, as well as its resolving power for protein digests. The results show core-shell nanoLC columns have similar van Deemter curves to the totally porous particle-packed nanoLC columns. For 100 mu m i.d. capillary columns, the core-shell material does not have significantly better dynamics. However, both core-shell and totally porous particle-packed nanoLC columns have shown high efficiencies: plate heights of similar to 11 mu m, equivalent to 90000 plates per meter, have been achieved with 5 mu m particles. Using a 60 cm long core-shell nanoLC column, 720 00 plates were realized in an isocratic separation of neutral compounds. For a 15 cm long nanoLC column, a maximum peak capacity of 220 has been achieved in a 5 hour gradient separation of protein digests, indicating the high resolving power of core-shell nanoLC columns. With a standard HeLa cell lysate as the sample, 2546 proteins were identified by using the core-shell nanoLC column, while 2916 proteins were identified by using the totally porous particle-packed nanoLC column. Comparing the two sets of proteomics data, it was found that 1830 proteins were identified by both columns, while 1086 and 716 proteins were uniquely identified by using totally porous and core-shell particle-packed nanoLC columns, respectively, suggesting their complementarity in nanoLC-MS based proteomics. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Electrochromatographic behavior of core-shell particles: A comparison study
    Yang, Lijun
    Xu, Lingjia
    Guo, Rui
    Gao, Tianyu
    Guo, Haoxin
    Yu, Yue
    Lv, Jijian
    Wang, Qiuquan
    Zhang, Bo
    ANALYTICA CHIMICA ACTA, 2018, 1033 : 205 - 212
  • [2] Core-shell particles lead the way to renewing high-performance liquid chromatography
    Gonzalez-Ruiz, Victor
    Olives, Ana I.
    Martin, M. Antonia
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 64 : 17 - 28
  • [3] Core-shell particles: Preparation, fundamentals and applications in high performance liquid chromatography
    Hayes, Richard
    Ahmed, Adham
    Edge, Tony
    Zhang, Haifei
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1357 : 36 - 52
  • [4] Size-exclusion chromatography using core-shell particles
    Pirok, Bob W. J.
    Breuer, Pascal
    Hoppe, Serafine J. M.
    Chitty, Mike
    Welch, Emmet
    Farkas, Tivadar
    van der Wal, Sjoerd
    Peters, Ron
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1486 : 96 - 102
  • [5] Towards a high peak capacity of 130 using nanoflow hydrophilic interaction liquid chromatography
    Liu, Ya
    Wang, Xiaofei
    Chen, Zhangqian
    Liang, Derek Hecheng
    Sun, Kaiyue
    Huang, Shanqing
    Zhu, Jue
    Shi, Xiaohui
    Zeng, Juxing
    Wang, Qiuquan
    Zhang, Bo
    ANALYTICA CHIMICA ACTA, 2019, 1062 : 147 - 155
  • [6] The History of the Core-Shell Particles and Applications in Active Pharmaceutical Ingredients Via Liquid Chromatography
    Gumustas, Mehmet
    Zalewski, Przemyslaw
    Ozkan, Sibel A.
    Uslu, Bengi
    CHROMATOGRAPHIA, 2019, 82 (01) : 17 - 48
  • [7] Pushing the performance limits of reversed-phase ultra high performance liquid chromatography with 1.3 μm core-shell particles
    Sanchez, A. Carl
    Friedlander, Gareth
    Fekete, Szabolcs
    Anspach, Jason
    Guillarme, Dvy
    Chitty, Mike
    Farkas, Tivadar
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1311 : 90 - 97
  • [8] Core-shell microspheres with porous nanostructured shells for liquid chromatography
    Ahmed, Adham
    Skinley, Kevin
    Herodotou, Stephanie
    Zhang, Haifei
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (01) : 99 - 124
  • [9] Maximizing the peak capacity using coupled columns packed with 2.6 μm core-shell particles operated at 1200 bar
    Vaast, Axel
    De Vos, Jelle
    Broeckhoven, Ken
    Verstraeten, Matthias
    Eeltink, Sebastiaan
    Desmet, Gert
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1256 : 72 - 79
  • [10] A "plug-and-use" approach towards facile fabrication of capillary columns for high performance nanoflow liquid chromatography
    Xiao, Zhiliang
    Wang, Lin
    Liu, Ya
    Wang, Qiuquan
    Zhang, Bo
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1325 : 109 - 114