Leak Detection and Location of Pipelines Based on LMD and Least Squares Twin Support Vector Machine

被引:54
作者
Liang, Xianming [1 ]
Li, Ping [2 ]
Hu, Zhiyong [3 ]
Ren, Hong [4 ]
li, Yan [1 ]
机构
[1] Northwestern Polytech Univ, Sch Automat, Xian 710072, Peoples R China
[2] Liaoning Shihua Univ, Sch Informat & Control Engn, Fushun 113001, Peoples R China
[3] Liaoning Shihua Univ, Sch Petrochem Engn, Fushun 113001, Peoples R China
[4] China Huanqiu Contracting & Engn Corp, Shenyang 110167, Peoples R China
基金
中国国家自然科学基金;
关键词
Local mean decomposition; wavelet analysis; least squares twin support vector machine (LSTSVM); leak aperture; leak location; Flowmaster software; LOCAL MEAN DECOMPOSITION; MULTICLASS CLASSIFICATION; FEATURE-EXTRACTION; ROLLER-BEARINGS; GAS-PIPELINE; DIAGNOSIS; WAVELET; ENTROPY; SIGNALS; SYSTEM;
D O I
10.1109/ACCESS.2017.2703122
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In oil pipeline leak detection and location, noise in the pressure signal collected at the end of the pipeline affects the accuracy of leak detection and the error of leakage location. To reduce the noise interference, an improved local mean decomposition signal analysis method is proposed. The production functions (PFs) that are related to the leak signal can be exacted, and it is necessary to know the characteristics of leak signals or noise in advance. According to the cross-correlation function, there is a significant peak between the measured signals, which are decomposed into a number of PFs. These reconstructed principal PF components are obtained, and a wavelet analysis is used to remove the noise in the reconstructed signal. On this basis, the signal features are extracted according to the time-domain feature and the waveform feature, which are input into the least squares twin support vector machine (LSTSVM), to recognize pipeline leaks. According to the reconstructed signal after wavelet denoising, the time-delay estimate of the negative pressure signal at the end of the pipeline is obtained by the cross-correlation function, and the leak location is ultimately calculated by combining the time delay with the leak signal propagation velocity. A flow model for pipeline leakage is proposed based on the Flowmaster software, where the collected data of the different working conditions are processed. The experimental results show that the proposed method can effectively identify different working conditions and accurately locate the leakage point.
引用
收藏
页码:8659 / 8668
页数:10
相关论文
共 36 条
[1]   A pressure-based method for monitoring leaks in a pipe distribution system: A Review [J].
Abdulshaheed, A. ;
Mustapha, F. ;
Ghavamian, A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 :902-911
[2]   Advanced signal processing of magnetic flux leakage data obtained from seamless gas pipeline [J].
Afzal, M ;
Udpa, S .
NDT & E INTERNATIONAL, 2002, 35 (07) :449-457
[3]   On-line twin independent support vector machines [J].
Alamdar, Fatemeh ;
Ghane, Sara ;
Amiri, Ali .
NEUROCOMPUTING, 2016, 186 :8-21
[4]   A novel feature selection method for twin support vector machine [J].
Bai, Lan ;
Wang, Zhen ;
Shao, Yuan-Hai ;
Deng, Nai-Yang .
KNOWLEDGE-BASED SYSTEMS, 2014, 59 :1-8
[5]   MLTSVM: A novel twin support vector machine to multi-label learning [J].
Chen, Wei-Jie ;
Shao, Yuan -Hai ;
Li, Chun-Na ;
Deng, Nai-Yang .
PATTERN RECOGNITION, 2016, 52 :61-74
[6]   A review on different pipeline fault detection methods [J].
Datta, Shantanu ;
Sarkar, Shibayan .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2016, 41 :97-106
[7]   Exact-differentiation-based leak detection and isolation in a plastic pipeline under temperature variations [J].
Delgado-Aguinaga, J. A. ;
Begovich, O. ;
Besancon, G. .
JOURNAL OF PROCESS CONTROL, 2016, 42 :114-124
[8]   Multi-leak diagnosis in pipelines based on Extended Kalman Filter [J].
Delgado-Aguinaga, J. A. ;
Besancon, G. ;
Begovich, O. ;
Carvajal, J. E. .
CONTROL ENGINEERING PRACTICE, 2016, 49 :139-148
[9]  
Dutta N, 2011, INNOVATIONS IN FUEL ECONOMY AND SUSTAINABLE ROAD TRANSPORT, P61
[10]   Feature extraction in pressure signals for leak detection in water networks [J].
Gamboa-Medina, M. M. ;
Ribeiro Reis, L. F. ;
Capobianco Guido, R. .
12TH INTERNATIONAL CONFERENCE ON COMPUTING AND CONTROL FOR THE WATER INDUSTRY, CCWI2013, 2014, 70 :688-697