Performance testing and optimization of a split-type air conditioner with evaporatively-cooled condenser

被引:34
作者
Atmaca, Ibrahim [1 ]
Senol, Ali [1 ]
Caglar, Ahmet [1 ]
机构
[1] Akdeniz Univ, Dept Mech Engn, TR-07070 Antalya, Turkey
来源
ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH | 2022年 / 32卷
关键词
Split-type air conditioner; Evaporative condenser; Performance improvement; Climatic conditions; Optimization; ARTIFICIAL NEURAL-NETWORK; ENERGY EFFICIENCY; REFRIGERATION SYSTEM; IMPROVEMENT;
D O I
10.1016/j.jestch.2021.09.010
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, the performance of a split-type air conditioner with evaporatively-cooled condenser was examined. The effect of evaporative cooling of the condenser on the performance parameters and energy efficiency were determined by comparing the results from an air conditioner with conventional type aircooled condenser. Both systems were tested simultaneously for different ambient conditions. An optimization study were also performed to find out the optimal climatic conditions for the proposed system. The effects of outdoor temperature and relative humidity on both total power consumption and COP were discussed. With the evaporative cooling of the condenser of the split-type air conditioner, the COP increased by 10.2%-35.3%, and the cooling capacity increased by 5.8%-18.6%, while the total power consumption decreased by 4%-12.4%. The results showed that the outdoor relative humidity and temperature had a significant influence on the COP, cooling capacity, and total power input for split-type air conditioners with an evaporative condenser. The results of the optimization study showed that the optimal condition maximizing the COP of the proposed system was confirmed as higher outdoor temperature and lower relative humidity. For the total power consumption, however, the optimal condition was found as medium levels of the temperature and humidity. The effect of the outdoor temperature on the electricity consumption is larger than that of the RH, and this provides an opportunity of using the proposed system in a wide-range climatic conditions.(c) 2021 Karabuk University. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
[41]   A novel design, implementation and performance evaluation of the first electronic expansion ejector for energy saving of a mini split air conditioner controlled by inverter [J].
Elsaid, Ashraf Mimi .
ENERGY CONVERSION AND MANAGEMENT, 2022, 260
[42]   The effect of wind on the optimal design and performance of a modular air-cooled condenser for a concentrated solar power plant [J].
Butler, C. ;
Grimes, R. .
ENERGY, 2014, 68 :886-895
[43]   Thermodynamic analysis the performance of hybrid solar-geothermal power plant equipped with air-cooled condenser [J].
Keshvarparast, Adele ;
Ajarostaghi, Seyed Soheil Mousavi ;
Delavar, Mojtaba Aghajani .
APPLIED THERMAL ENGINEERING, 2020, 172
[44]   Optimization of a polarized photometric detector equipped with a split-type flow cell and its analytical application to oligo-saccharides [J].
Yamamoto, A ;
Wataya, T ;
Hayakawa, K ;
Matsunaga, A ;
Nishimura, M ;
Miyazaki, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) :1383-1387
[45]   Investigating On Effect Of Fan Blades Angle Of A Water-cooled Air Conditioner On Its Performance Through CFD Analysis [J].
Zhang, Yingying .
JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2025, 28 (11) :2149-2160
[46]   Cooling performance optimization of air-cooled battery thermal management system [J].
Wang, Meiwei ;
Teng, Shiyang ;
Xi, Huan ;
Li, Yuquan .
APPLIED THERMAL ENGINEERING, 2021, 195
[47]   Performance criterion of an indirect dry air-cooled condenser for small modular reactor based on pressure transition temperature [J].
Shin, Doyoung ;
Na, Min Wook ;
Lee, Jeong Ik ;
Kim, Yonghee ;
Kim, Sung Joong .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) :8190-8203
[48]   Thermal and exergy analysis of optimal performance and refrigerant for an air conditioner split unit under different Iraq climatic conditions [J].
Tarish, Ali Lateef ;
Hamzah, Mushtaq Talib ;
Jwad, Wasan Assad .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 19
[49]   Stochastic modelling of flexible load characteristics of split-type air conditioners using grey-box modelling and random forest method [J].
Jiang, Zhihao ;
Peng, Jinqing ;
Yin, Rongxin ;
Hu, Maomao ;
Cao, Jingyu ;
Zou, Bin .
ENERGY AND BUILDINGS, 2022, 273
[50]   Performance analysis of a novel heat pump type air conditioner coupled with a liquid dehumidification/humidification cycle [J].
Cai, Dehua ;
Qiu, Chengbo ;
Zhang, Jiazheng ;
Liu, Yue ;
Liang, Xiao ;
He, Guogeng .
ENERGY CONVERSION AND MANAGEMENT, 2017, 148 :1291-1305