Validation of cell voltage and water content in a PEM (polymer electrolyte membrane) fuel cell model using neutron imaging for different operating conditions

被引:49
作者
Antonio Salva, J. [1 ]
Iranzo, Alfredo [1 ]
Rosa, Felipe [2 ]
Tapia, Elvira [1 ]
机构
[1] Sch Engn, AICIA, Seville, Spain
[2] Univ Seville, Thermal Engn Grp, Energy Engn Dept, Sch Engn, Camino Descubrimientos S-N, Seville, Spain
关键词
PEM (polymer electrolyte membrane) fuel cell; Model validation; Water management; Neutron imaging; REDUCTION REACTION; OXYGEN REDUCTION; NAFION INTERFACE; PERFORMANCE; DEPENDENCE; FLOW; SIMULATION; PREDICTION; KINETICS; LAYER;
D O I
10.1016/j.energy.2016.02.006
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents a one dimensional analytical model developed for a 50 cm(2) PEM (polymer electrolyte membrane) fuel cell with five-channel serpentine flow field. The different coupled physical phenomena such as electrochemistry, mass transfer of hydrogen, oxygen and water (two phases) together with heat transfer have been solved simultaneously. The innovation of this work is that the model has been validated with two different variables simultaneously and quantitatively in order to ensure the accuracy of the results. The selected variables are the cell voltage and the water content within the membrane MEA (Membrane Electrode Assembly) and GDL (gas diffusion layers) experimentally measured by means of neutron radiography. The results show a good agreement for a comprehensive set of different operating conditions of cell temperature, pressure, reactants relative humidity and cathode stoichiometry. The analytical model has a relative error less than 3.5% for the value of the cell voltage and the water content within the GDL + MEA for all experiments performed. This result presents a new standard of validation in the state of art of PEM fuel cell modeling where two variables are simultaneously and quantitatively validated with experimental results. The developed analytical model has been used in order to analyze the behavior of the PEM fuel cell under different values of relative humidity. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 112
页数:13
相关论文
共 40 条
  • [1] Analysis of PEM (Polymer Electrolyte Membrane) fuel cell cathode two-dimensional modeling
    Abdollahzadeh, M.
    Pascoa, J. C.
    Ranjbar, A. A.
    Esmaili, Q.
    [J]. ENERGY, 2014, 68 : 478 - 494
  • [2] Numerical investigation of flow field configuration and contact resistance for PEM fuel cell performance
    Akbari, Mohammad Hadi
    Rismanchi, Behzad
    [J]. RENEWABLE ENERGY, 2008, 33 (08) : 1775 - 1783
  • [3] [Anonymous], 2011, FUEL CELLS MOD MAN
  • [4] Modelling and simulation of the steady-state and dynamic behaviour of a PEM fuel cell
    Asl, S. M. Sharifi
    Rowshanzamir, S.
    Eikani, M. H.
    [J]. ENERGY, 2010, 35 (04) : 1633 - 1646
  • [5] Review of proton exchange membrane fuel cell models
    Biyikoglu, A
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2005, 30 (11) : 1181 - 1212
  • [6] Modeling the temperature distribution and performance of a PEM fuel cell with thermal contact resistance
    Cao, Tao-Feng
    Mu, Yu-Tong
    Ding, Jing
    Lin, Hong
    He, Ya-Ling
    Tao, Wen-Quan
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 87 : 544 - 556
  • [7] Water droplet accumulation and motion in PEM (Proton Exchange Membrane) fuel cell mini-channels
    Carton, J. G.
    Lawlor, V.
    Olabi, A. G.
    Hochenauer, C.
    Zauner, G.
    [J]. ENERGY, 2012, 39 (01) : 63 - 73
  • [8] Experimental measurement of effective diffusion coefficient of gas diffusion layer/microporous layer in PEM fuel cells
    Chan, Carl
    Zamel, Nada
    Li, Xianguo
    Shen, Jun
    [J]. ELECTROCHIMICA ACTA, 2012, 65 : 13 - 21
  • [9] 3D effects of water-saturation distribution on polymeric electrolyte fuel cell (PEFC) performance
    Cordiner, Stefano
    Lanzani, Simon Pietro
    Mulone, Vincenzo
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (16) : 10366 - 10375
  • [10] European Comission, 2010, TEST VOLT POW FUNCT