Biomechanical Comparison of 2 Double Plating Methods in a Coronal Fracture Model of Bicondylar Tibial Plateau Fractures

被引:3
作者
Samsami, Shabnam [1 ]
Patzold, Robert [2 ,3 ]
Neuy, Tim [4 ]
Greinwald, Markus [2 ]
Muller, Peter E. [5 ]
Chevalier, Yan [5 ]
Puschel, Klaus [6 ]
Augat, Peter [2 ,7 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
[2] Berufsgenossenschaftl Unfallklin, Dept Inst Biomech, Murnau, Germany
[3] Berufsgenossenschaftl Unfallklin, Dept Trauma Surg, Murnau, Germany
[4] Paracelsus Med Univ, Med Dept, Salzburg, Austria
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Orthopaed Phys Med & Rehabil, Munich, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Forens Med, Hamburg, Germany
[7] Paracelsus Med Univ, Dept Inst Biomech, Salzburg, Austria
关键词
bicondylar tibial plateau fracture; posteromedial fracture fragment; coronal fracture model; double plating osteosynthesis; mechanical test; interfragmentary movement; LESS INVASIVE STABILIZATION; POSTEROMEDIAL FRAGMENT; INTERNAL-FIXATION; REDUCTION; CLASSIFICATION; MORPHOLOGY; LOCKING; SINGLE;
D O I
10.1097/BOT.0000000000002257
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Because management of bicondylar tibial plateau fractures are complicated even for expert surgeons, with using a coronal fracture model, we aimed to compare 2 kinds of double locked plating techniques that consisted of the lateral locking plate and the medial locking plate inserted medial anteriorly (MA-ly) or medial posteriorly (MP-ly). Methods: Fourteen fresh-frozen tibias stabilized with the MA or MP methods were allocated into 2 groups with similar bone mineral density values. Implanted samples were tested under incremental fatigue loading conditions using a customized load applicator. An optical motion tracking system was used to assess relative displacements and rotations of fracture fragments during loading. Static and dynamic global stiffness, failure load, failure cycles, as well as movements of fracture fragments were measured. Results: There were no significant differences between the 2 fixation methods regarding global stiffness, failure load, or failure cycles (P = 0.67-0.98, depending on the parameter). The kinematic evaluations, however, revealed that different positions of the medial locking plates altered the directions of movements for the medial-anterior or medial-posterior fracture segments. Conclusions: The mechanical stability of tibia-implant constructs fixed with the double plating methods was not remarkably affected by the location of the medial locking plate. Depending on clinical conditions and surgeons' preferences, bicondylar tibial plateau fractures can be managed with either MA or MP methods.
引用
收藏
页码:E129 / E135
页数:7
相关论文
共 50 条
[21]   Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures—a finite-element investigation [J].
J. Dehoust ;
M. Münch ;
K. Seide ;
T. Barth ;
K.-H. Frosch .
European Journal of Trauma and Emergency Surgery, 2020, 46 :1257-1266
[22]   A comparative biomechanical study for complex tibial plateau fractures: Nailing and compression bolts versus modern and traditional plating [J].
Lasanianos, Nikolaos G. ;
Garnavos, Christos ;
Magnisalis, Evangelos ;
Kourkoulis, Stavros ;
Babis, George C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10) :1333-1339
[23]   Predictors of reduction loss in tibial plateau fracture surgery: Focusing on posterior coronal fractures [J].
Kim, Chang-Wan ;
Lee, Chang-Rack ;
An, Ki-Chan ;
Gwak, Heui-Chul ;
Kim, Jung-Han ;
Wang, Lih ;
Yoon, Dong-Gil .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (07) :1483-1487
[24]   The pivotal role of the coronal fracture line for a new three-dimensional CT-based fracture classification of bicondylar proximal tibial fractures [J].
Paetzold, Robert ;
Friederichs, Jan ;
von Rueden, Christian ;
Panzer, Stephanie ;
Buehren, Volker ;
Augat, Peter .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (10) :2214-2220
[25]   Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study [J].
Thamyongkit, Sorawut ;
Abbasi, Pooyan ;
Parks, Brent G. ;
Shafiq, Babar ;
Hasenboehler, Erik A. .
BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
[26]   Bicondylar tibial plateau fracture osteosynthesis with double-plate fixation: Similar complication rates and clinical results but improved radiographic outcomes with dual compared to single approach* [J].
Dobelle, Emile ;
Fabre-Aubrespy, Maxime ;
Mandon, Bastien ;
Flecher, Xavier ;
Ollivier, Matthieu ;
Argenson, Jean-Noel ;
Jacquet, Christophe .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (02)
[27]   Single versus dual incision approaches for dual plating of bicondylar tibial plateau fractures have comparable rates of deep infection and revision surgery [J].
Guild, Theodore T. ;
Stenquist, Derek S. ;
Yeung, Caleb M. ;
Harris, Mitchel B. ;
Von Keudell, Arvind G. ;
Smith, R. Malcolm .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10) :3475-3480
[28]   Comparison of three fixations for tibial plateau fractures by biomechanical study and radiographic observation [J].
Chen, Hong-wei ;
Liu, Guo-dong ;
Ou, Shan ;
Jiang, Xie-yuan ;
Fei, Jun ;
Wu, Li-jun .
INTERNATIONAL JOURNAL OF SURGERY, 2015, 13 :292-296
[29]   Does maintaining external fixators during definitive fixation of bicondylar tibial plateau fractures influence fracture alignment and deep infection rates? [J].
Mickley, John ;
Philips, William ;
Colosimo, Sara ;
Kurtic, Dinela ;
Gitlin, Adam ;
Young, Porter .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (03)
[30]   Biomechanical evaluation of fixation techniques for posteromedial tibial plateau fractures: A cadaveric model [J].
Kalem, Mahmut ;
Baltaci, Cagatay ;
Acar, Halil Ibrahim ;
Uslan, Yunus ;
Perdeci, Elif Naz ;
Sahin, Ercan .
JOINT DISEASES AND RELATED SURGERY, 2025,