Biomechanical Comparison of 2 Double Plating Methods in a Coronal Fracture Model of Bicondylar Tibial Plateau Fractures

被引:2
|
作者
Samsami, Shabnam [1 ]
Patzold, Robert [2 ,3 ]
Neuy, Tim [4 ]
Greinwald, Markus [2 ]
Muller, Peter E. [5 ]
Chevalier, Yan [5 ]
Puschel, Klaus [6 ]
Augat, Peter [2 ,7 ]
机构
[1] Imperial Coll London, Dept Mech Engn, South Kensington Campus, London SW7 2AZ, England
[2] Berufsgenossenschaftl Unfallklin, Dept Inst Biomech, Murnau, Germany
[3] Berufsgenossenschaftl Unfallklin, Dept Trauma Surg, Murnau, Germany
[4] Paracelsus Med Univ, Med Dept, Salzburg, Austria
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Orthopaed Phys Med & Rehabil, Munich, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Forens Med, Hamburg, Germany
[7] Paracelsus Med Univ, Dept Inst Biomech, Salzburg, Austria
关键词
bicondylar tibial plateau fracture; posteromedial fracture fragment; coronal fracture model; double plating osteosynthesis; mechanical test; interfragmentary movement; LESS INVASIVE STABILIZATION; POSTEROMEDIAL FRAGMENT; INTERNAL-FIXATION; REDUCTION; CLASSIFICATION; MORPHOLOGY; LOCKING; SINGLE;
D O I
10.1097/BOT.0000000000002257
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Because management of bicondylar tibial plateau fractures are complicated even for expert surgeons, with using a coronal fracture model, we aimed to compare 2 kinds of double locked plating techniques that consisted of the lateral locking plate and the medial locking plate inserted medial anteriorly (MA-ly) or medial posteriorly (MP-ly). Methods: Fourteen fresh-frozen tibias stabilized with the MA or MP methods were allocated into 2 groups with similar bone mineral density values. Implanted samples were tested under incremental fatigue loading conditions using a customized load applicator. An optical motion tracking system was used to assess relative displacements and rotations of fracture fragments during loading. Static and dynamic global stiffness, failure load, failure cycles, as well as movements of fracture fragments were measured. Results: There were no significant differences between the 2 fixation methods regarding global stiffness, failure load, or failure cycles (P = 0.67-0.98, depending on the parameter). The kinematic evaluations, however, revealed that different positions of the medial locking plates altered the directions of movements for the medial-anterior or medial-posterior fracture segments. Conclusions: The mechanical stability of tibia-implant constructs fixed with the double plating methods was not remarkably affected by the location of the medial locking plate. Depending on clinical conditions and surgeons' preferences, bicondylar tibial plateau fractures can be managed with either MA or MP methods.
引用
收藏
页码:E129 / E135
页数:7
相关论文
共 50 条
  • [1] The effect of coronal splits on the structural stability of bi-condylar tibial plateau fractures: a biomechanical investigation
    Samsami, Shabnam
    Paetzold, Robert
    Winkler, Martin
    Herrmann, Sven
    Augat, Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1719 - 1730
  • [2] Lateral Locked Plating or Dual Plating: A Comparison of Two Methods in Simple Bicondylar Tibial Plateau Fractures
    Citak, Caner
    Kayali, Cemil
    Ozan, Firat
    Altay, Taskin
    Karahan, Huseyin Gokhan
    Yamak, Kamil
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) : 151 - 158
  • [3] Biomechanical analysis of dual versus lateral locked plating in elderly bicondylar tibial plateau fractures: Does medial comminution matter?
    Velez, Dencel A. Garcia
    Headford, Mikel
    Suresh, Krishna Vangipuram
    Liberatos, Paraskevi Marousa
    Bledsoe, Gary
    Revak, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10): : 3109 - 3114
  • [4] Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures
    Neogi, Devdatta Suhas
    Trikha, Vivek
    Mishra, Kaushal Kant
    Bandekar, Shivanand M.
    Yadav, Chandra Shekhar
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 193 - 198
  • [5] Bicondylar tibial plateau fracture treated by open reduction and fixation with unilateral locked plating
    Lee, Tien-Ching
    Huang, Hsuan-Ti
    Lin, Yu-Chuan
    Chen, Chung-Hwan
    Cheng, Yuh-Min
    Chen, Jian-Chih
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2013, 29 (10) : 568 - 577
  • [6] The Comparative Analysis of Single Plating Versus Double Plating in the Treatment of Unstable Bicondylar Proximal Tibial Plateau Fractures
    Raj, Manish
    Singh, Santosh Kumar
    Rajput, Ajay K.
    Gill, Simrat Pal
    Verma, Satyendra K.
    Sonarkar, Sushant S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [7] Dual locked plating of unstable bicondylar tibial plateau fractures
    Ozkaya, Ufuk
    Parmaksizoglu, Atilla Sancar
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S9 - S13
  • [8] Dual plating or dual plating combined with compression bolts for bicondylar tibial plateau fractures: a retrospective comparative study
    Wang, Zhongzheng
    Wang, Yuchuan
    Tian, Siyu
    Tan, Zhanchao
    Deng, Xiangtian
    Zhao, Kuo
    Zheng, Zhanle
    Chen, Wei
    Hou, Zhiyong
    Zhang, Yingze
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Outcome Analysis of Dual Plating in Management of Unstable Bicondylar Tibial Plateau Fracture - A Prospective Study
    Raj, M.
    Gill, S. P. S.
    Rajput, A.
    Singh, K. S.
    Verma, K. S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (03) : 29 - 35
  • [10] Stabilization of the Posteromedial Fragment in Bicondylar Tibial Plateau Fractures: A Mechanical Comparison of Locking and Nonlocking Single and Dual Plating Methods
    Yoo, Brad J.
    Beingessner, Daphne M.
    Barei, David P.