Comparative analysis of free cooling of photovoltaics - phase change versus evaporative cooling

被引:11
作者
Arkar, Ciril [1 ]
Zizak, Tej [1 ]
Domjan, Suzana [1 ]
Medved, Saso [1 ]
机构
[1] Univ Ljubljana, Fac Mech Engn, Lab Sustainable Technol Bldg, Ljubljana 1000, Slovenia
关键词
Solar energy; Photovoltaics; Free cooling of PV; Phase-change materials; Evaporative cooling; PV MODULE; NATURAL-CONVECTION; PCM; PERFORMANCE; PANEL; ENHANCEMENT; EFFICIENCY;
D O I
10.1016/j.est.2022.104162
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Free cooling of PV cells is a common research topic; it lowers the operating temperature of PV cells, resulting in higher electricity production. This article investigated free cooling techniques for the wide range of thermal properties of the PCM layer installed on the backside of the PV cell. Two options were assumed: micro-encapsulated PCM in which heat is transferred by conduction only, and macro-encapsulated PCM in which heat transfer is enhanced by convection. The effect of free cooling with PCM was compared with the evaporative cooling technique. The thermal response of virtual PV cells (vPV) was evaluated with in-situ experiments. One vPV was upgraded with a micro-encapsulated 5.2 mm thick PCM layer, another with an evaporative layer. Multi-parametric approximation models of the PV cell temperature and combined surface heat transfer coefficients were developed. Approximation models of temperatures were used for the determination of overheating hours (OHH) for the reference and evaporatively cooled vPV, while combined surface heat transfer coefficient models were used in the developed numerical model of thermal response of vPV with micro-and macro-encapsulated PCM. The required thermal properties of PCM were determined to provide the same efficacy of free cooling as an evaporative cooling technique for three selected climate conditions (Stockholm, Ljubljana, and Athens). The study shows that the free cooling of PV cells with PCM could be as efficient as evaporative cooling, but only in the hottest and coldest observed climates if the thermal conductivity of PCM is above 1.8 W/mK for micro-and above 1.2 W/mK for macro-encapsulated PCM, and the latent heat capacity is above 250 kJ/kg. In the milder climate, free cooling will not be as efficient as evaporative cooling (for the defined ranges of thermal properties). It was determined that for such a climate, the additional heat transfer resistance of the PCM layer increases overheating of PV cells if the PCM's thermal conductivity is below 0.4 W/mK and the latent heat capacity is below 150 kJ/kg.
引用
收藏
页数:13
相关论文
共 34 条
  • [11] Passive cooling of standalone flat PV module with cotton wick structures
    Chandrasekar, M.
    Suresh, S.
    Senthilkumar, T.
    Karthikeyana, M. Ganesh
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 71 : 43 - 50
  • [12] Quantification of the natural convection perturbations on differential scanning calorimetry measurements of PCMs
    David, Damien
    Johannes, Kevyn
    Kuznik, Frederic
    [J]. THERMOCHIMICA ACTA, 2017, 655 : 145 - 154
  • [13] Numerical simulation of a PCM packed bed system: A review
    de Gracia, Alvaro
    Cabeza, Luisa F.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 : 1055 - 1063
  • [14] On an experimental innovative setup for the macro scale thermal analysis of materials: Application to the Phase Change Material (PCM) wallboards
    Eddhahak-Ouni, Anissa
    Colin, Johan
    Bruneau, Denis
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 231 - 238
  • [15] Performance comparison of a double-axis sun tracking versus fixed PV system
    Eke, Rustu
    Senturk, Ali
    [J]. SOLAR ENERGY, 2012, 86 (09) : 2665 - 2672
  • [16] Performance of a PV module integrated with standalone building in hot arid areas as enhanced by surface cooling and cleaning
    Elnozahy, Ahmed
    Rahman, Ali K. Abdel
    Ali, Ahmed Hamza H.
    Abdel-Salam, Mazen
    Ookawara, S.
    [J]. ENERGY AND BUILDINGS, 2015, 88 : 100 - 109
  • [17] Experimental Analysis of a Novel PV/T Panel with PCM and Heat Pipes
    Gonzalez-Pena, David
    Alonso-deMiguel, Ivan
    Diez-Mediavilla, Montserrat
    Alonso-Tristan, Cristina
    [J]. SUSTAINABILITY, 2020, 12 (05)
  • [18] Experimental investigation of the passive cooled free-standing photovoltaic panel with fixed aluminum fins on the backside surface
    Grubisic-Cabo, Filip
    Nizetic, Sandro
    Coko, Duje
    Kragic, Ivo Marinic
    Papadopoulos, Agis
    [J]. JOURNAL OF CLEANER PRODUCTION, 2018, 176 : 119 - 129
  • [19] Experimental investigation of evaporative cooling for enhancing photovoltaic panels efficiency
    Haidar, Zeyad A.
    Orfi, Jamel
    Kaneesamkandi, Zakariya
    [J]. RESULTS IN PHYSICS, 2018, 11 : 690 - 697
  • [20] Experimental and numerical studies on performance of PCM-based heat sink with different configurations of internal fins
    Hosseinizadeh, S. F.
    Tan, F. L.
    Moosania, S. M.
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) : 3827 - 3838