ECONOMIC ANALYSIS OF EFFECT ON ENERGY SAVING OF THERMAL INSULATION AT BUILDINGS IN ERZINCAN PROVINCE

被引:0
作者
Kaya, Mehmet [1 ]
Firat, Ilker [2 ]
Comakli, Omer [3 ]
机构
[1] Erzincan Univ, Muhendisl Fak, Makine Muhendisligi Bolumu, TR-24100 Merkez Erzincan, Turkey
[2] Erzincan Univ, Ilic Dursun Yildirim Meslek Yuksekokulu Elekt & E, TR-24700 Ilic Erzincan, Turkey
[3] Ataturk Univ, Muhendisl Fak, Makine Muhendisligi Bolumu, TR-25100 Merkez Erzurum, Turkey
关键词
Heat losses; Insulation; Economic analysis; Energy saving; EXTERNAL WALLS; THICKNESS;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, heat losses were determined in the sample heat insulated and uninsulated buildings in Erzincan Province and heat loss economic analysis was made. As a result of the study, it is identified that total heat transfer surface area in the buildings in Erzincan is 2411189,77 m(2). 31,36 per cent of this area is insulated and 68,64 per cent is uninsulted. Because, the insulted buildings' insulation thicknesses differ, 4, 5 and 8 cm insulation thickness calculations were made according to the projects that was made in Erzincan before. Assuming that the insulated buildings built with 4 cm XPS, total heating cost was determined as 194914060,8 TL/year. If the uninsulated buildings have 4 cm XPS standart total annual heating cost would decrease to 85380229,75 TL/year and there would be 43,80 per cent saving. If insulation thicknesses is 5 cm and 8 cm, total annual saving respectively would be 41,49 per cent and 38,81 per cent.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 22 条
[1]  
[Anonymous], 2012, ERZINCAN BELEDIYESI
[2]  
[Anonymous], 2012, ERZINCAN METEOROLOJI
[3]   Thermoeconomic optimization of insulation thickness considering condensed vapor in buildings [J].
Arslan, Oguz ;
Kose, Ramazan .
ENERGY AND BUILDINGS, 2006, 38 (12) :1400-1408
[4]  
Aytac A, 2006, J FAC ENG ARCHIT GAZ, V21, P753
[5]  
Bayer G, 2006, DISSERTATION
[6]   Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in Turkey [J].
Bolatturk, A .
APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) :1301-1309
[7]   Optimum insulation thickness of external walls for energy saving [J].
Çomakli, K ;
Yüksel, B .
APPLIED THERMAL ENGINEERING, 2003, 23 (04) :473-479
[8]   The environmental impact of optimum insulation thickness for external walls of buildings [J].
Dombayci, Oe. Altan .
BUILDING AND ENVIRONMENT, 2007, 42 (11) :3855-3859
[9]   An estimation of the residential space heating energy requirement in Cyprus using the regional average specific heat loss coefficient [J].
Evcil, Ali .
ENERGY AND BUILDINGS, 2012, 55 :164-173
[10]  
Firat I., 2013, THESIS ATATURK U