Performance characteristics of five cardiac Troponin I assays
被引:16
作者:
La'ulu, Sonia L.
论文数: 0引用数: 0
h-index: 0
机构:
ARUP Inst Clin & Expt Pathol, Salt Lake City, UT USAARUP Inst Clin & Expt Pathol, Salt Lake City, UT USA
La'ulu, Sonia L.
[1
]
Roberts, William L.
论文数: 0引用数: 0
h-index: 0
机构:
ARUP Inst Clin & Expt Pathol, Salt Lake City, UT USA
Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84132 USAARUP Inst Clin & Expt Pathol, Salt Lake City, UT USA
Roberts, William L.
[1
,2
]
机构:
[1] ARUP Inst Clin & Expt Pathol, Salt Lake City, UT USA
[2] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84132 USA
Troponin I;
99th percentile;
Functional sensitivity;
Imprecision;
Method comparison;
MEDICINE PRACTICE GUIDELINES;
CLINICAL BIOCHEMISTRY;
NATIONAL ACADEMY;
99TH PERCENTILE;
DEFINITION;
MARKERS;
D O I:
10.1016/j.cca.2010.04.008
中图分类号:
R446 [实验室诊断];
R-33 [实验医学、医学实验];
学科分类号:
1001 ;
摘要:
Background: The aim of this study was to evaluate the performance characteristics of cardiac Troponin I (cTnI) assays on the Access 2, Advia Centaur, Architect i1000(SR), Architect i2000(SR), and Vitros ECi analyzers. Methods: To determine the 99th percentile, plasma and serum samples were drawn from 400 apparently healthy subjects. Functional sensitivity was evaluated by testing 10 panels of serum pools in duplicate for 10 days using 2 reagent lots. Imprecision was also assessed using commercial quality control materials. For method comparison, 100 plasma samples were tested by all methods with the Architect i2000(SR) assay as the comparison method. Results: The 99th percentile ranged from 0.013 to 0.020 mu g/l. Calculated CVs at the 99th percentile were 23-52%. cTnI concentrations at a 10% CV ranged from 0.039 to 0.101 mu g/l. Total CVs determined using quality control materials were 2.4-10.0%. Method comparison results by Deming regression had slopes of 1.03-1.51. The mean bias for cTnI samples between 0.01 and 1.0 mu g/l ranged from 0 to 0.2 mu g/l. Conclusions: No method demonstrated a concentration with a 10% CV that was less than the 99th percentile for healthy adults. All methods compare well to the Architect 12000(SR) assay with the Advia Centaur having the highest positive bias. (C) 2010 Elsevier B.V. All rights reserved.
机构:
St George Hosp, Dept Cardiol, London SW17 0RE, NA, England
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Collinson, Paul O.
;
Clifford-Mobley, Oliver
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Clifford-Mobley, Oliver
;
Gaze, David
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Gaze, David
;
Boa, Frances
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Boa, Frances
;
Senior, Roxy
论文数: 0引用数: 0
h-index: 0
机构:
Northwick Pk Hosp & Clin Res Ctr, Dept Cardiol, London, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
机构:
St George Hosp, Dept Cardiol, London SW17 0RE, NA, England
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Collinson, Paul O.
;
Clifford-Mobley, Oliver
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Clifford-Mobley, Oliver
;
Gaze, David
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Gaze, David
;
Boa, Frances
论文数: 0引用数: 0
h-index: 0
机构:
St George Hosp, Dept Clin Blood Sci, London SW17 0RE, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England
Boa, Frances
;
Senior, Roxy
论文数: 0引用数: 0
h-index: 0
机构:
Northwick Pk Hosp & Clin Res Ctr, Dept Cardiol, London, EnglandSt George Hosp, Dept Cardiol, London SW17 0RE, NA, England