Influence of airway management on ventilator-associated pneumonia - Evidence from randomized trials

被引:129
作者
Cook, D
De Jonghe, B
Brochard, L
Brun-Buisson, C
机构
[1] St Josephs Hosp, Dept Med, Hamilton, ON L8N 4A6, Canada
[2] McMaster Univ, Hamilton, ON, Canada
[3] Hop Poissy, Serv Reanimat Med, Poissy, France
[4] Univ Paris 12, Hop Henri Mondor, Serv Reanimat Med, F-94010 Creteil, France
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 1998年 / 279卷 / 10期
关键词
D O I
10.1001/jama.279.10.781
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective.-Ventilator-associated pneumonia (VAP) is a serious complication of critical illness, conferring increased morbidity and mortality. Many interventions have been studied to reduce the risk of VAP. We systematically reviewed the influence of airway management on VAP in critically ill patients. Data Sources.-Studies were identified through searching MEDLINE and EMBASE from 1980 through July 1997 and by searching SCISEARCH, the Cochrane Library, bibliographies of primary and review articles, personal files, and contact with authors of the randomized trials. Study Selection.-We selected randomized trials evaluating ventilator circuit and secretion management strategies on the rate of VAP. Data Extraction.-Two investigators independently abstracted key data on design features, the population, intervention, and outcome of the studies. Data Synthesis.-The frequency of ventilator circuit changes and the type of endotracheal suction system do not appear to influence VAP rates (3 trials, none with significant difference; range of relative risks [RRs], 0.84-0.91). However, lower VAP rates may be associated with avoidance of heated humidifiers and use of heat and moisture exchangers (5 trials, only 1 showing a significant difference; range of RRs, 0.34-0.86), use of oral vs nasal intubation (1 trial; RR, 0.52; 95% confidence interval, 0.24-1.13), subglottic secretion drainage vs standard endotracheal tubes (2 trials, 1 showing a significant difference; range of RRs, 0.46-0.57), and kinetic vs conventional beds (5 trials, only 1 showing a significant difference; range of RRs, 0.35-0.78). Conclusions.-Some ventilator circuit and secretion management strategies may influence VAP rates in critically ill patients. Whether these strategies are adopted in practice depends on several factors such as the magnitude and precision of estimates of benefit and harm, as well as access, availability, and costs.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 65 条
[1]  
AERDTS SJA, 1993, BRIT MED J, V307, P525
[2]  
[Anonymous], AM J RESP CRIT CARE
[3]   Intermittent enteral feeding: The influence on respiratory and digestive tract colonization in mechanically ventilated intensive-care-unit patients [J].
Bonten, MJM ;
Gaillard, CA ;
vanderHulst, R ;
deLeeuw, PW ;
vanderGeest, S ;
Stobberingh, EE ;
Soeters, PB .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (02) :394-399
[4]   ENTERAL VERSUS PARENTERAL-NUTRITION AFTER SEVERE CLOSED-HEAD INJURY [J].
BORZOTTA, AP ;
PENNINGS, J ;
PAPASADERO, B ;
PAXTON, J ;
MARDESIC, S ;
BORZOTTA, R ;
PARROTT, A ;
BLEDSOE, F .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 37 (03) :459-468
[5]   INVASIVE DIAGNOSTIC TESTING SHOULD BE ROUTINELY USED TO MANAGE VENTILATED PATIENTS WITH SUSPECTED PNEUMONIA [J].
CHASTRE, J ;
FAGON, JY .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (02) :570-574
[6]   USE OF HEAT AND MOISTURE EXCHANGING (HME) FILTERS IN MECHANICALLY VENTILATED ICU PATIENTS - INFLUENCE ON AIRWAY FLOW-RESISTANCE [J].
CHIARANDA, M ;
VERONA, L ;
PINAMONTI, O ;
DOMINIONI, L ;
MINOJA, G ;
CONTI, G .
INTENSIVE CARE MEDICINE, 1993, 19 (08) :462-466
[7]   EFFECTS OF THE HEAT-MOISTURE EXCHANGERS ON DYNAMIC HYPERINFLATION OF MECHANICALLY VENTILATED COPD PATIENTS [J].
CONTI, G ;
DEBLASI, RA ;
ROCCO, M ;
PELAIA, P ;
ANTONELLI, M ;
BUFI, M ;
MATTIA, C ;
GASPARETTO, A .
INTENSIVE CARE MEDICINE, 1990, 16 (07) :441-443
[8]   Systematic review: The relation between nutrition and nosocomial pneumonia: randomized trials in critically ill patients [J].
Deborah Cook ;
Bernard De Jonghe ;
Daren Heyland .
Critical Care, 1 (1)
[9]  
Cook DJ, 1996, JAMA-J AM MED ASSOC, V275, P308, DOI 10.1001/jama.275.4.308
[10]   Systematic reviews: Synthesis of best evidence for clinical decisions [J].
Cook, DJ ;
Mulrow, CD ;
Haynes, RB .
ANNALS OF INTERNAL MEDICINE, 1997, 126 (05) :376-380