The John Charnley Award Metal-on-Metal Hip Resurfacing versus Large-diameter Head Metal-on-Metal Total Hip Arthroplasty A Randomized Clinical Trial

被引:237
|
作者
Garbuz, Donald S. [1 ]
Tanzer, Michael [2 ]
Greidanus, Nelson V. [1 ]
Masri, Bassam A. [1 ]
Duncan, Clive P. [1 ]
机构
[1] Univ British Columbia, Div Lower Limb Reconstruct & Oncol, Dept Orthopaed, Vancouver, BC V5Z 4E3, Canada
[2] McGill Univ, Dept Surg, Div Orthopaed Arthroplasty, Montreal, PQ H3A 2T5, Canada
关键词
FOLLOW-UP; FEMORAL-NECK; REPLACEMENT; COBALT; OSTEOARTHRITIS; VALIDATION; PROSTHESES; CHROMIUM; RELEASE; BLOOD;
D O I
10.1007/s11999-009-1029-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Resurfacing arthroplasty has become an attractive option for young patients who want to maintain a high activity level. One recent study reported modestly increased activity levels for patients with resurfacing compared to standard total hip arthroplasty (THA). We conducted a prospective randomized clinical trial to compare clinical outcomes of resurfacing versus large-head metal-on-metal total hip arthroplasty. We randomized 107 patients deemed eligible for resurfacing arthroplasty to have either resurfacing or standard THA. Patients were assessed for quality-of-life outcomes using the PAT-5D index, WOMAC, SF-36, and UCLA activity score. The minimum followup was 0.8 years (mean, 1.1 years; range, 0.8-2.2 years). Of the 73 patients followed at least one year, both groups reported improvement in quality of life on all outcome measures. There was no difference in quality of life between the two arms in the study. Serum levels of cobalt and chromium were measured in a subset of 30 patients. In both groups cobalt and chromium was elevated compared to baseline. Patients receiving a large-head metal-on-metal total hip had elevated ion levels compared to the resurfacing arm of the study. At 1 year, the median serum cobalt increased 46-fold from baseline in patients in the large-head total hip group, while the median serum chromium increased 10-fold. At 1 year, serum cobalt was 10-fold higher and serum chromium 2.6-fold higher than in the resurfacing arm. Due to these excessively high metal ion levels, the authors recommend against further use of this particular large-head total hip arthroplasty.
引用
收藏
页码:318 / 325
页数:8
相关论文
共 50 条
  • [21] Femoral Revision in Hip Resurfacing Compared With Large-Bearing Metal-on-Metal Hip Arthroplasty
    Garrett, Simon J. W.
    Bolland, Ben J. R. F.
    Yates, Piers J.
    Gardner, Edward M. H.
    Latham, Jeremy M.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1214 - 1218
  • [22] Revision Total Hip Arthroplasty for Aseptically Failed Metal-On-Metal Hip Resurfacing Arthroplasty
    Salmons, Harold I.
    Fruth, Kristin M.
    Lewallen, David G.
    Trousdale, Robert T.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12) : 2399 - 2405
  • [23] Early failures in large head metal-on-metal total hip arthroplasty
    Althuizen, Martje N. R.
    Hooff, Miranda L. V.
    Erp, Saskia H. M. V. D. Berg-v.
    Limbeek, Jacques V.
    Nijhof, Marc W.
    HIP INTERNATIONAL, 2012, 22 (06) : 641 - 647
  • [24] Metal ion levels decrease after revision for metallosis arising from large-diameter metal-on-metal hip arthroplasty
    Ebreo, Darren
    Khan, Abdul
    El-Meligy, Mohammed
    Armstrong, Catherine
    Peter, Viju
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (06): : 777 - 781
  • [25] Total Hip Arthroplasty Using Large-Diameter Metal-On-Metal Articulation in Patients With Neuromuscular Weakness
    Park, Kyung-Soon
    Seon, Jong-Keun
    Lee, Keun-Bae
    Yoon, Taek-Rim
    JOURNAL OF ARTHROPLASTY, 2014, 29 (04) : 797 - 801
  • [26] Corrosion at the Cone/Taper Interface Leads to Failure of Large-diameter Metal-on-metal Total Hip Arthroplasties
    Meyer, Heiko
    Mueller, Tina
    Goldau, Gesine
    Chamaon, Kathrin
    Ruetschi, Marcel
    Lohmann, Christoph H.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) : 3101 - 3108
  • [27] Echocardiographic Changes in the Context of Metal-on-Metal Versus Nonmetal-on-Metal Total Hip Arthroplasty
    Darrith, Brian
    Rahman, Tahsin M.
    Ananthasubramaniam, Karthikeyan
    Culvern, Chris
    Jacobs, Joshua J.
    Silverton, Craig D.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (11) : 3230 - +
  • [28] Complications After Metal-on-Metal Hip Resurfacing Arthroplasty
    Amstutz, Harlan C.
    Le Duff, Michel J.
    Campbell, Patricia A.
    Wisk, Lauren E.
    Takamura, Karren M.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) : 207 - +
  • [29] Large-diameter metal-on-metal total hip arthroplasties: A page in orthopedic history?
    Singh, Gurpal
    Meyer, Heiko
    Ruetschi, Marcel
    Chamaon, Kathrin
    Feuerstein, Bernd
    Lohmann, Christoph H.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2013, 101 (11) : 3320 - 3326
  • [30] Co and Cr accumulation in hair after metal-on-metal hip resurfacing arthroplasty
    Liu, Fu-Cun
    Qin, Jian
    Wu, Hai-Shan
    Wu, Yu-Li
    Zhu, Yun-Li
    ANZ JOURNAL OF SURGERY, 2011, 81 (06) : 436 - 439