Experimental Study of the Rate of OH + HO2 → H2O + O2 at High Temperatures Using the Reverse Reaction

被引:62
作者
Hong, Zekai [1 ]
Vasu, Subith S. [1 ]
Davidson, David F. [1 ]
Hanson, Ronald K. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
EVALUATED KINETIC-DATA; POTENTIAL-ENERGY SURFACE; RATE-CONSTANT; SHOCK-TUBE; HYDROGEN COMBUSTION; HO2; IGNITION; ENTHALPY; WAVE; DISSOCIATION;
D O I
10.1021/jp100739t
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The rate constant of the reaction OH + HO2 -> H2O + O-2 (1) can be inferred at high temperatures from measurements of the rate of its reverse reaction H2O + O-2 -> OH + HO2 (-1). In this work, we used laser absorption of both H2O and OH to study the reverse reaction in shock-heated H2O/O-2/Ar mixtures over the temperature range 1600-2200 K. Initial H2O concentrations were determined using tunable diode laser absorption near 2.5 mu m, and OH concentration time-histories were measured using UV ring dye laser absorption near 306.7 nm. Detailed kinetic analysis of the OH time-history profiles yielded a value for the rate constant k(1) of (3.3 +/- 0.9) x 10(13) [cm(3) mol(-1) s(-1)] between 1600 and 2200K. The results of this study agree well with those reported by Srinivasan et al. (Srinivasan, N.K.; Su, M.-C.; Sutherland, J.W.; Michael, J.V.; Ruscic, B. J. Phys. Chem. A 2006, 110, 6602-6607) in the temperature regime between 1200 and 1700 K. The combination of the two studies suggests only a weak temperature dependence of k(1) above 1200 K. Data from the current study and that of Keyser (Keyser, L.F.J. Phys. Chem. 1988, 92, 1193-1200) at lower temperatures can be described by the k(1) expression proposed by Baulch et al. (Baulch, D.L.; Cobos, C.J.; Cox, R.A.; Esser, C.; Frank, P.; Just, Th.; Kerr, J.A.; Pilling, Mi.; Troe, J.; Walker, R.W.; Warnatz, J. J. Phys. Chem. Ref Data 1992, 21, 411), k(1) = 2.89 x 10(13) exp(252/T) [cm(3) mol(-1) s(-1)]. However, it should be noted that some previous studies suggest a k(1) minimum around 1250 K (Hippler, H.; Neunaber, H.; Troe, J. J. Chem. Phys. 1995, 103, 3510-3516) or 1000 K (Kappel, C.; Luther, K.; Troe, J. Phys. Chem. Chem. Phys. 2002, 4, 4392-4398).
引用
收藏
页码:5520 / 5525
页数:6
相关论文
共 45 条
[1]   Evaluated kinetic data for combustion modeling: Supplement II [J].
Baulch, DL ;
Bowman, CT ;
Cobos, CJ ;
Cox, RA ;
Just, T ;
Kerr, JA ;
Pilling, MJ ;
Stocker, D ;
Troe, J ;
Tsang, W ;
Walker, RW ;
Warnatz, J .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 2005, 34 (03) :757-1397
[2]   EVALUATED KINETIC DATA FOR COMBUSTION MODELING [J].
BAULCH, DL ;
COBOS, CJ ;
COX, RA ;
ESSER, C ;
FRANK, P ;
JUST, T ;
KERR, JA ;
PILLING, MJ ;
TROE, J ;
WALKER, RW ;
WARNATZ, J .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1992, 21 (03) :411-734
[3]   EVALUATED KINETIC DATA FOR COMBUSTION MODELING SUPPLEMENT-I [J].
BAULCH, DL ;
COBOS, CJ ;
COX, RA ;
FRANK, P ;
HAYMAN, G ;
JUST, T ;
KERR, JA ;
MURRELLS, T ;
PILLING, MJ ;
TROE, J ;
WALKER, RW ;
WARNATZ, J .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1994, 23 (06) :847-1033
[4]   QUANTUM CALCULATIONS ON THE RATE-CONSTANT FOR THE O + OH REACTION [J].
CLARY, DC ;
WERNER, HJ .
CHEMICAL PHYSICS LETTERS, 1984, 112 (04) :346-350
[5]   RATE COEFFICIENT FOR THE REACTION OH+HO2=H2O+O2 AT 1-ATMOSPHERE PRESSURE AND 308-K [J].
COX, RA ;
BURROWS, JP ;
WALLINGTON, TJ .
CHEMICAL PHYSICS LETTERS, 1981, 84 (02) :217-221
[7]   Shock tube measurements of iso-octane ignition times and OH concentration time histories [J].
Davidson, DF ;
Oehlschlaeger, MA ;
Herbon, JT ;
Hanson, RK .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2002, 29 (01) :1295-1301
[8]  
ETHAN AB, 2009, THESIS STANFORD U ST
[9]   Transported PDF modelling with detailed chemistry of pre- and auto-ignition in CH4/air mixtures [J].
Gkagkas, K. ;
Lindstedt, R. P. .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2007, 31 :1559-1566
[10]   KINETICS OF THE REACTION BETWEEN OH AND HO2 ON THE TRIPLET POTENTIAL-ENERGY SURFACE [J].
GONZALEZ, C ;
THEISEN, J ;
SCHLEGEL, HB ;
HASE, WL ;
KAISER, EW .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (04) :1767-1774