Mini-FLOTAC for counting Toxoplasma gondii oocysts from cat feces - Comparison with cell counting plates

被引:4
|
作者
Djokic, Vitomir [1 ,2 ]
Blaga, Radu [3 ]
Rinaldi, Laura [4 ]
Le Roux, Delphine [3 ]
Ducry, Tamara [1 ]
Maurelli, Maria Paola [4 ]
Perret, Catherine [1 ]
Djakovic, Olgica Djurkovic [2 ]
Cringoli, Giuseppe [4 ]
Boireau, Pascal [1 ]
机构
[1] Univ Paris Est, UMR BIPAR, Lab Sante Anim Maisons Alfort, ANSES, Maisons Alfort, France
[2] Univ Belgrade, Inst Med Res, Natl Reference Lab Toxoplasmosis, Belgrade 11129, Serbia
[3] Univ Paris Est, UMR BIPAR, Ecole Natl Vet Alfort, Maisons Alfort, France
[4] Univ Naples Federico II, Dept Vet Med & Anim Prod, Naples, Italy
关键词
Toxoplasma gondii; Oocysts; Detection; Mini-FLOTAC; Kova slide; REAL-TIME PCR; RISK-FACTORS; PREGNANT-WOMEN; INFECTION; DIAGNOSIS; TRANSMISSION; ANIMALS; IDENTIFICATION; EXTRACTION; ANTIBODIES;
D O I
10.1016/j.exppara.2014.10.009
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Oocysts of Toxoplasma gondii represent one of the most common environmental contaminants causing the zoonotic infection toxoplasmosis. The aim of the present study was to compare the Mini-FLOTAC device with traditional cell counting plates (Kova Slide) for the detection of T. gondii oocysts from feline feces. Two types of experiments were performed: (i) purified oocysts were counted in different dilutions and (ii) specific pathogen free T. gondii-negative cat feces was inoculated with numbers of purified oocysts and counting was performed directly from feces. Our analysis showed a thousand times higher sensitivity of Mini-FLOTAC (5 x 10(2) oocysts) compared to Kova Slide (5 x 10(5) oocysts). Also, when compared by McNemar's test, counting of the purified oocysts showed a higher sensitivity of Mini-FLOTAC compared to Kova Slide, for a dilution of 10(3) oocysts/ml (chi(2) = 6.1; P < 0.05). A better sensitivity was also found with Mini-FLOTAC in dilutions of 10(5) and 10(4) oocysts/ml, when counted from feces (chi(2) = 4.2 and 8.1, respectively, P < 0.05). Our results show that Mini-FLOTAC is more sensitive than traditional methods of T. gondii oocysts detection and quantification is more accurate. Furthermore, Mini-FLOTAC simplicity and cost effectiveness allow it to be used with light microscopes in any laboratory or field conditions. We therefore recommend its use for regular screening. Further studies are needed to validate Mini-FLOTAC for the detection of oocysts in soil and water samples in field conditions. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:67 / 71
页数:5
相关论文
共 21 条
  • [1] A comparison of the FECPAK and Mini-FLOTAC faecal egg counting techniques
    Godber, Olivia F.
    Phythian, Clare J.
    Bosco, Antonio
    Ianniello, Davide
    Coles, Gerald
    Rinaldi, Laura
    Cringoli, Giuseppe
    VETERINARY PARASITOLOGY, 2015, 207 (3-4) : 342 - 345
  • [2] TOXOPLASMA-GONDII OOCYSTS IN FECES OF NATURALLY INFECTED CAT
    PAMPIGLIONE, S
    POGLAYEN, G
    ARNONE, B
    DELALIA, F
    BMJ-BRITISH MEDICAL JOURNAL, 1973, 2 (5861): : 306 - 306
  • [3] Evaluation of accuracy and precision of a smartphone based automated parasite egg counting system in comparison to the McMaster and Mini-FLOTAC methods
    Scare, J. A.
    Slusarewicz, P.
    Noel, M. L.
    Wielgus, K. M.
    Nielsen, M. K.
    VETERINARY PARASITOLOGY, 2017, 247 : 85 - 92
  • [4] Comparison between McMaster and Mini-FLOTAC methods for the enumeration of Eimeria maxima oocysts in poultry excreta
    Bortoluzzi, C.
    Paras, K. L.
    Applegate, T. J.
    Verocai, G. G.
    VETERINARY PARASITOLOGY, 2018, 254 : 21 - 25
  • [5] TOXOPLASMA GONDII OOCYST FROM CAT FECES
    DUBEY, JP
    MILLER, NL
    FRENKEL, JK
    JOURNAL OF EXPERIMENTAL MEDICINE, 1970, 132 (04): : 636 - &
  • [6] A comparison of mini-FLOTAC and FLOTAC with classic methods to diagnosing intestinal parasites of dogs from Brazil
    Victor Fernando Santana Lima
    Giuseppe Cringoli
    Laura Rinaldi
    Maria Fernanda Melo Monteiro
    Andréa Maria Campos Calado
    Rafael Antonio Nascimento Ramos
    Patrícia Oliveira Meira-Santos
    Leucio Câmara Alves
    Parasitology Research, 2015, 114 : 3529 - 3533
  • [7] A comparison of mini-FLOTAC and FLOTAC with classic methods to diagnosing intestinal parasites of dogs from Brazil
    Santana Lima, Victor Fernando
    Cringoli, Giuseppe
    Rinaldi, Laura
    Melo Monteiro, Maria Fernanda
    Campos Calado, Andrea Maria
    Nascimento Ramos, Rafael Antonio
    Meira-Santos, Patrcia Oliveira
    Alves, Leucio Camara
    PARASITOLOGY RESEARCH, 2015, 114 (09) : 3529 - 3533
  • [8] Detection of Toxoplasma gondii-like oocysts in cat feces and estimates of the environmental oocyst burden
    Dabritz, Haydee A.
    Miller, Mellisa A.
    Atwill, E. Robert
    Gardner, Ian A.
    Leutenegger, Christian M.
    Melli, Ann C.
    Conrad, Patricia A.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2007, 231 (11): : 1676 - 1684
  • [9] ISOLATION OF TOXOPLASMA GONDII FROM FECES OF AHELMINTH FREE CAT
    DUBEY, JP
    JOURNAL OF PROTOZOOLOGY, 1968, 15 (04): : 773 - &
  • [10] SARCOCYSTIS IN MICE INOCULATED WITH TOXOPLASMA-LIKE OOCYSTS FROM CAT FECES
    WALLACE, GD
    SCIENCE, 1973, 180 (4093) : 1375 - 1377