Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

被引:17
|
作者
Yunaga, Hiroto [1 ]
Ohta, Yasutoshi [1 ]
Kaetsu, Yasuhiro [2 ]
Kitao, Shinichiro [1 ]
Watanabe, Tomomi [3 ]
Furuse, Yoshiyuki [3 ]
Yamamoto, Kazuhiro [3 ]
Ogawa, Toshihide [1 ]
机构
[1] Tottori Univ, Div Radiol, Dept Pathophysiol Therapeut Sci, Fac Med, 36-1 Nishi Cho, Yonago, Tottori 6838504, Japan
[2] Kakogawa Higashi Hosp, Dept Cardiol, Kakogawa, Hyogo, Japan
[3] Tottori Univ, Div Cardiol, Dept Mol Med & Therapeut, Fac Med, Yonago, Tottori, Japan
关键词
Coronary vessels; Vascular calcification; Radiography; dual-energy scanned projection; Tomography; X-ray computed; Coronary angiography; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ARTERY-DISEASE; ACCURACY; STENOSIS; CALCIUM; SEVERITY; TESTS;
D O I
10.1007/s00330-016-4675-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. aEuro cent Computed tomography angiography tends to overestimate stenosis in calcified coronary artery. aEuro cent Dual-energy CT enables us to suppress calcification of coronary artery lesions. aEuro cent Calcification-suppressed material density imaging reduces false-positive diagnosis of calcified lesion.
引用
收藏
页码:2794 / 2801
页数:8
相关论文
共 50 条
  • [1] Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT
    Hiroto Yunaga
    Yasutoshi Ohta
    Yasuhiro Kaetsu
    Shinichiro Kitao
    Tomomi Watanabe
    Yoshiyuki Furuse
    Kazuhiro Yamamoto
    Toshihide Ogawa
    European Radiology, 2017, 27 : 2794 - 2801
  • [2] Diagnostic Accuracy of Rapid Kilovolt Peak-Switching Dual-Energy CT Coronary Angiography in Patients With a High Calcium Score
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Bertella, Erika
    Conte, Edoardo
    Segurini, Chiara
    Giovannardi, Marta
    Baggiano, Andrea
    Annoni, Andrea
    Formenti, Alberto
    Petulla, Maria
    Beltrama, Virginia
    Volpato, Valentina
    Bartorelli, Antonio L.
    Trabattoni, Daniela
    Fiorentini, Cesare
    Pepi, Mauro
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (06) : 746 - 748
  • [3] Diagnostic Accuracy of Rapid Kilovolt Peak-Switching Dual-Energy CT Coronary Angiography in Patients with High Calcium Score
    Mushtaq, S.
    Pontone, G.
    Annoni, A.
    Conte, E.
    Baggiano, A.
    Segurini, C.
    Volpato, V.
    Pepi, M.
    Fiorentini, C.
    Andreini, D.
    EUROPEAN HEART JOURNAL, 2015, 36 : 866 - 867
  • [4] Coronary Artery Imaging with Single-Source Rapid Kilovolt Peak-Switching Dual-Energy CT
    Scheske, Jonathan A.
    O'Brien, Julie M.
    Earls, James P.
    Min, James K.
    LaBounty, Troy M.
    Cury, Ricardo C.
    Lee, Ting-Yim
    So, Aaron
    Hague, Cameron J.
    Al-Hassan, Donya
    Kuriyabashi, Sachio
    Dowe, David A.
    Leipsic, Jonathon A.
    RADIOLOGY, 2013, 268 (03) : 702 - 709
  • [5] Analysis of coronary arterial calcification components with coronary CT angiography using single-source dual-energy CT with fast tube voltage switching
    Matsui, Kazuhiro
    Machida, Haruhiko
    Mitsuhashi, Tetsuya
    Omori, Hisako
    Nakaoka, Takashi
    Sakura, Hiroshi
    Ueno, Eiko
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (03): : 639 - 647
  • [6] Analysis of coronary arterial calcification components with coronary CT angiography using single-source dual-energy CT with fast tube voltage switching
    Kazuhiro Matsui
    Haruhiko Machida
    Tetsuya Mitsuhashi
    Hisako Omori
    Takashi Nakaoka
    Hiroshi Sakura
    Eiko Ueno
    The International Journal of Cardiovascular Imaging, 2015, 31 : 639 - 647
  • [7] Dual-Energy CT for Diagnostic CT Colonography
    Karcaaltincaba, Musturay
    Ozdeniz, Ilknur
    RADIOGRAPHICS, 2014, 34 (03) : 847 - 847
  • [8] Quantification of Coronary Artery Calcium on the Basis of Dual-Energy Coronary CT Angiography
    Schwarz, Florian
    Nance, John W., Jr.
    Ruzsics, Balazs
    Bastarrika, Gorka
    Sterzik, Alexander
    Schoepf, U. Joseph
    RADIOLOGY, 2012, 264 (03) : 700 - 707
  • [9] Dual-Energy CT for Diagnostic CT Colonography Response
    Cai, Wenli
    Lee, June-Goo
    Yoshida, Hiroyuki
    Kim, Se Hyung
    RADIOGRAPHICS, 2014, 34 (03)
  • [10] Reduced iodine load with CT coronary angiography using dual-energy imaging: A prospective randomized trial compared with standard coronary CT angiography
    Raju, Rekha
    Thompson, Angus G.
    Lee, Kristy
    Precious, Bruce
    Yang, Tae-Hyun
    Berger, Adam
    Taylor, Carolyn
    Heilbron, Brett
    Nguyen, Giang
    Earls, James
    Min, James
    Carrascosa, Patricia
    Murphy, Darra
    Hague, Cameron
    Leipsic, Jonathon A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (04) : 282 - 288