Needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer

被引:37
作者
Yoshida, Ken [1 ]
Yamazaki, Hideya [2 ]
Nose, Takayuki [3 ]
Shiomi, Hiroya [4 ]
Yoshida, Mineo
Mikami, Mari
Takenaka, Tadashi
Kotsuma, Tadayuki
Tanaka, Eiichi
Kuriyama, Keiko
Harada, Yasunori [5 ]
Tohda, Akira [5 ]
Yasunaga, Yutaka [5 ]
Oka, Toshitsugu [5 ]
机构
[1] Osaka Natl Hosp, Natl Hosp Org, Dept Radiol, Chuo Ku, Osaka 5400006, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, Kyoto, Japan
[3] Canc Inst Hosp, Dept Radiat Oncol, Tokyo, Japan
[4] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, Osaka, Japan
[5] Osaka Natl Hosp, Natl Hosp Org, Dept Urol, Osaka 5400006, Japan
关键词
Applicator displacement; Ambulatory technique; High-dose-rate interstitial brachytherapy; Prostate cancer; HDR BRACHYTHERAPY; EXTERNAL-BEAM; MONOTHERAPY; CATHETER; FEASIBILITY; FRACTIONS; MOVEMENT;
D O I
10.1016/j.brachy.2009.04.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To introduce an effective ambulatory technique in high-dose-rate interstitial brachytherapy (HDR-ISBT) for prostate cancer, we investigated the displacement distance using our novel calculation method. METHODS AND MATERIALS: Sixty-four patients treated with HDR-ISBT as monotherapy were examined. Of these, 4, 17, and 43 patients were administered treatment doses of 38 Gy (3 days), 49 Gy (4 days), and 54 Gy (5 days), respectively. For dose administration, we used 776 flexible applicators with a removable template (ambulatory technique). Using CT images, we calculated the relative coordinates of the metal markers and applicators. From these coordinates, to analyze displacement during treatment, we measured the distance between the tip of the needle applicator and the center of gravity of the markers along the average applicator vector. RESULTS: The median displacement distance for all applicators was 7 mm (range, -14 to 24), and that of each treatment schedule was 4, 6, and 9 mm for 38, 49, and 54 Gy, respectively. Of the 776 applicators, displacement of >10 mm was seen in 198 (26%) applicators and >15 mm in 57 (7%) applicators. Body height (p < 0.0001) and anticoagulant usage (p < 0.0001) were significant factors influencing displacement. CONCLUSIONS: We investigated needle applicator displacement using our unique method. Additional cranial margins are necessary if there is no repositioning of the dwell position. CT scanning should be performed daily during treatment for checking the position of the applicator to detect and rectify the issue of displacement. (C) 2010 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
[31]   High-dose-rate brachytherapy for prostate cancer: Rationale, current applications, and clinical outcome [J].
Strouthos, Iosif ;
Karagiannis, Efstratios ;
Zamboglou, Nikolaos ;
Ferentinos, Konstantinos .
CANCER REPORTS, 2022, 5 (01)
[32]   A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer [J].
Guirado, Damian ;
Ruiz-Arrebola, Samuel ;
Tornero-Lopez, Ana M. ;
de la Vega, Jose M. ;
Prada, Pedro J. ;
Lallena, Antonio M. .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (02) :193-200
[33]   Factors Affecting Prostate Displacement During Volumetric Modulated Arc Therapy in Prone Position After High-Dose-Rate Brachytherapy for Prostate Cancer [J].
Sakurai, Takayuki ;
Takamatsu, Shigeyuki ;
Shibata, Satoshi ;
Minamikawa, Risako ;
Yamazaki, Masahiro ;
Kojima, Hironori ;
Noto, Kimiya ;
Makino, Tomoyuki ;
Kawaguchi, Shohei ;
Nohara, Takahiro ;
Mizokami, Atsushi ;
Gabata, Toshifumi .
ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (06)
[34]   Safety of high-dose-rate brachytherapy in patients with prostate cancer and inflammatory bowel disease: A case series [J].
Thomas, Horatio ;
Chen, Jie Jane ;
Shaheen, Haitham ;
Sabbagh, Ali ;
Abdul-Baki, Hasan ;
Chau, Oi Wai ;
Malik, Nauman ;
Ayoub, Alan ;
Hassanzadeh, Comron ;
Hsu, I-Chow ;
Mohamad, Osama .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2024, 16 (01) :1-5
[35]   High-dose-rate interstitial brachytherapy in combination with androgen deprivation therapy for prostate cancer Are high-risk patients good candidates? [J].
Yoshida, Ken ;
Yamazaki, Hideya ;
Takenaka, Tadashi ;
Kotsuma, Tadayuki ;
Yoshida, Mineo ;
Masui, Koji ;
Yoshioka, Yasuo ;
Narumi, Yoshifumi ;
Oka, Toshitsugu ;
Tanaka, Eiichi .
STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (11) :1015-1020
[36]   Lessons learned using an MRI-only workflow during high-dose-rate brachytherapy for prostate cancer [J].
Murgic, Jure ;
Chung, Peter ;
Berlin, Alejandro ;
Bayley, Andrew ;
Warde, Padraig ;
Catton, Charles ;
Simeonov, Anna ;
Abed, Jessamine ;
O'Leary, Gerald ;
Rink, Alexandra ;
Menard, Cynthia .
BRACHYTHERAPY, 2016, 15 (02) :147-155
[37]   High-dose-rate brachytherapy for localized prostate adenocarcinoma post abdominoperineal resection of the rectum and pelvic irradiation: Technique and experience [J].
Jabbari, Siavash ;
Hsu, I. -Chow ;
Kawakami, Jun ;
Weinberg, Vivian K. ;
Speight, Joycelyn L. ;
Gottschalk, Alexander R. ;
Roach, Mack, III ;
Shinohara, Katsuto .
BRACHYTHERAPY, 2009, 8 (04) :339-344
[38]   Simultaneous needle catheter selection and dwell time optimization for preplanning of high-dose-rate brachytherapy of prostate cancer [J].
Wang, Chao ;
Gonzalez, Yesenia ;
Shen, Chenyang ;
Hrycushko, Brian ;
Jia, Xun .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05)
[39]   High-Dose-Rate Prostate Brachytherapy An Excellent Accelerated-Hypofractionated Treatment for Favorable Prostate Cancer [J].
Martinez, Alvaro A. ;
Demanes, Jeffrey ;
Vargas, Carlos ;
Schour, Lionel ;
Ghilezan, Michel ;
Gustafson, Gary S. .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2010, 33 (05) :481-488
[40]   Dosimetry of local failure with single dose 19 Gy high-dose-rate brachytherapy for prostate cancer [J].
Armstrong, Shreya ;
Tsang, Yatman ;
Lowe, Gerry ;
Tharmalingam, Hannah ;
Alonzi, Roberto ;
Ostler, Peter ;
Hughes, Robert ;
Hoskin, Peter .
RADIOTHERAPY AND ONCOLOGY, 2021, 157 :93-98