Needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer

被引:36
|
作者
Yoshida, Ken [1 ]
Yamazaki, Hideya [2 ]
Nose, Takayuki [3 ]
Shiomi, Hiroya [4 ]
Yoshida, Mineo
Mikami, Mari
Takenaka, Tadashi
Kotsuma, Tadayuki
Tanaka, Eiichi
Kuriyama, Keiko
Harada, Yasunori [5 ]
Tohda, Akira [5 ]
Yasunaga, Yutaka [5 ]
Oka, Toshitsugu [5 ]
机构
[1] Osaka Natl Hosp, Natl Hosp Org, Dept Radiol, Chuo Ku, Osaka 5400006, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, Kyoto, Japan
[3] Canc Inst Hosp, Dept Radiat Oncol, Tokyo, Japan
[4] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, Osaka, Japan
[5] Osaka Natl Hosp, Natl Hosp Org, Dept Urol, Osaka 5400006, Japan
关键词
Applicator displacement; Ambulatory technique; High-dose-rate interstitial brachytherapy; Prostate cancer; HDR BRACHYTHERAPY; EXTERNAL-BEAM; MONOTHERAPY; CATHETER; FEASIBILITY; FRACTIONS; MOVEMENT;
D O I
10.1016/j.brachy.2009.04.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To introduce an effective ambulatory technique in high-dose-rate interstitial brachytherapy (HDR-ISBT) for prostate cancer, we investigated the displacement distance using our novel calculation method. METHODS AND MATERIALS: Sixty-four patients treated with HDR-ISBT as monotherapy were examined. Of these, 4, 17, and 43 patients were administered treatment doses of 38 Gy (3 days), 49 Gy (4 days), and 54 Gy (5 days), respectively. For dose administration, we used 776 flexible applicators with a removable template (ambulatory technique). Using CT images, we calculated the relative coordinates of the metal markers and applicators. From these coordinates, to analyze displacement during treatment, we measured the distance between the tip of the needle applicator and the center of gravity of the markers along the average applicator vector. RESULTS: The median displacement distance for all applicators was 7 mm (range, -14 to 24), and that of each treatment schedule was 4, 6, and 9 mm for 38, 49, and 54 Gy, respectively. Of the 776 applicators, displacement of >10 mm was seen in 198 (26%) applicators and >15 mm in 57 (7%) applicators. Body height (p < 0.0001) and anticoagulant usage (p < 0.0001) were significant factors influencing displacement. CONCLUSIONS: We investigated needle applicator displacement using our unique method. Additional cranial margins are necessary if there is no repositioning of the dwell position. CT scanning should be performed daily during treatment for checking the position of the applicator to detect and rectify the issue of displacement. (C) 2010 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
  • [1] Assessment of Daily Needle Applicator Displacement during High-Dose-Rate Interstitial Brachytherapy for Prostate Cancer using Daily CT Examinations
    Takenaka, Tadashi
    Yoshida, Ken
    Ueda, Mari
    Yamazaki, Hideya
    Miyake, Shunsuke
    Tanaka, Eiichi
    Yoshida, Mineo
    Yoshimura, Yasushi
    Oka, Toshitsugu
    Honda, Kazuya
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (03) : 469 - 474
  • [2] Daily computed tomography measurement of needle applicator displacement during high-dose-rate interstitial brachytherapy for previously untreated uterine cervical cancer
    Mikami, Mari
    Yoshida, Ken
    Takenaka, Tadashi
    Yamazaki, Hideya
    Kotsuma, Tadayuki
    Yoshida, Mineo
    Aramoto, Kazumasa
    Yamada, Shigetoshi
    Ban, Chiaki
    Tanaka, Eiichi
    Honda, Kazuya
    BRACHYTHERAPY, 2011, 10 (04) : 318 - 324
  • [3] Daily CT Measurement of Needle Applicator Displacement during Multifractionated High-dose-rate Interstitial Brachytherapy for Postoperative Recurrent Uterine Cancer
    Yoshida, Ken
    Ueda, Mari
    Takenaka, Tadashi
    Yamazaki, Hideya
    Kotsuma, Tadayuki
    Aramoto, Kazumasa
    Miyake, Shunsuke
    Koretsune, Yukihiro
    Ban, Chiaki
    Tanaka, Eiichi
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (02) : 295 - 300
  • [4] High-dose-rate brachytherapy as monotherapy for prostate cancer
    Demanes, D. Jeffrey
    Ghilezan, Michel I.
    BRACHYTHERAPY, 2014, 13 (06) : 529 - 541
  • [5] Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI
    Buus, Simon
    Lizondo, Maria
    Hokland, Steffen
    Rylander, Susanne
    Pedersen, Erik M.
    Tanderup, Kari
    Bentzen, Lise
    BRACHYTHERAPY, 2018, 17 (01) : 50 - 58
  • [6] Dosimetric effect of interfractional needle displacement in prostate high-dose-rate brachytherapy
    Kovalchuk, Nataliya
    Furutani, Keith M.
    MacDonald, O. Kenneth
    Pisansky, Thomas M.
    BRACHYTHERAPY, 2012, 11 (02) : 111 - 118
  • [7] Catheter displacement prior to the delivery of high-dose-rate brachytherapy in the treatment of prostate cancer patients
    Kawakami, Shogo
    Ishiyama, Hiromichi
    Terazaki, Tsuyoshi
    Soda, Itaru
    Satoh, Takefumi
    Kitano, Masashi
    Kurosaka, Shinji
    Sekiguchi, Akane
    Komori, Shouko
    Iwamura, Masatsugu
    Hayakawa, Kazushige
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (02) : 161 - 166
  • [8] High-dose-rate brachytherapy boost for prostate cancer: Outcomes and genitourinary toxicity
    Bece, Andrej
    Patanjali, Nitya
    Jackson, Michael
    Whitaker, May
    Hruby, George
    BRACHYTHERAPY, 2015, 14 (05) : 670 - 676
  • [9] High-dose-rate brachytherapy as monotherapy for prostate cancer: technique, rationale and perspective
    Yoshioka, Yasuo
    Suzuki, Osamu
    Otani, Yuki
    Yoshida, Ken
    Nose, Takayuki
    Ogawa, Kazuhiko
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 91 - 98
  • [10] New ambulatory implant technique of high-dose-rate interstitial brachytherapy for prostate cancer
    Yoshida K.
    Nose T.
    Shiomi H.
    Yoshioka Y.
    Fujita Y.
    Kuroda S.
    Yoshida M.
    Takahashi T.
    Kitamura M.
    Akai H.
    Oka T.
    Hosoki T.
    Radiation Medicine, 2006, 24 (8): : 595 - 599