Uncertainties of gas chromatographic measurement of troublesome pesticide residues in apples employing conventional and mass spectrometric detectors

被引:39
作者
Stepán, R [1 ]
Hajslová, J [1 ]
Kocourek, V [1 ]
Tichá, J [1 ]
机构
[1] Inst Chem Technol, Dept Food Chem & Anal, CR-16628 Prague 6, Czech Republic
关键词
uncertainty of measurement; bottom-up; top-down; pesticide residues; plant matrices; gas chromatography;
D O I
10.1016/j.aca.2004.05.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years the declaration of estimated uncertainty of measurement has become an integral part of analytical results. This study presents the assessment of results generated within the analysis of selected pesticides represented by carbamates, pyrethroides and azoles, residues of which may be found in treated apples. Multiresidue method used for analysis of spiked samples (residues at levels 0.040-0.163 mg/kg) consisted of (i) ethyl acetate extraction, (ii) GPC clean-up and (iii) identification/quantification of residues by GC. Procedures utilizing either conventional (electron-capture, nitrogen-phosphorus) or mass-selective detectors (quadrupole and ion trap analyzer) were evaluated. The results generated through alternative strategies of uncertainty estimation ("bottom-up", "top-down") were compared. Using the "bottom-up" approach uncertainty of extraction which comprises two components-(i) repeatability of extraction and (ii) uncertainty of extraction recovery was shown to represent the main source of combined standard uncertainty (values of uncertainty of extraction for tested pesticides ranged from 4.6% to 21.6%). On the other hand, uncertainties associated with the GC calibration (uncertainties of weighing and diluting standards, uncertainties of purity of standards) were not so important (most of them did not exceed 2%). Combined standard uncertainties associated with the described analytical method ranged for individual compounds from 9.3% to 24.3%. Similar values of combined standard uncertainties were obtained using the alternative "top-down" approach. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:245 / 255
页数:11
相关论文
共 25 条
[1]  
[Anonymous], 2004, LC GC N AM
[2]  
[Anonymous], 21748 ISOTS
[3]  
[Anonymous], 2002, Off. J. Eur. Comm, VL221, P8
[4]  
[Anonymous], PESTICIDE MANUAL
[5]  
[Anonymous], 4032012 WST
[6]  
[Anonymous], 1994, ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
[7]   Determination of fungicide residues in fruits and vegetables by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry [J].
Blasco, C ;
Picó, Y ;
Mañes, J ;
Font, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (02) :227-235
[8]   Estimation of the uncertainty in a multiresidue method for the determination of pesticide residues in fruit and vegetables [J].
Christensen, HB ;
Poulsen, ME ;
Pedersen, M .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2003, 20 (08) :764-775
[9]   Assessment of uncertainty in pesticide multiresidue analytical methods:: main sources and estimation [J].
Cuadros-Rodríguez, L ;
Torres, MEH ;
López, EA ;
González, FJE ;
Liébanas, FJA ;
Vidal, JLM .
ANALYTICA CHIMICA ACTA, 2002, 454 (02) :297-314
[10]  
da Silva RJNB, 2000, ANALYST, V125, P1459, DOI 10.1039/b000801j