T2-and diffusion-weighted magnetic resonance imaging at 3 T for the detection of prostate cancer with and without endorectal coil: An intraindividual comparison of image quality and diagnostic performance

被引:35
作者
Baur, Alexander D. J. [1 ]
Daqqaq, Tareef [1 ]
Wagner, Moritz [1 ]
Maxeiner, Andreas [2 ]
Huppertz, Alexander [3 ]
Renz, Diane [3 ]
Hamm, Bernd [1 ]
Fischer, Thomas [1 ]
Durmus, Tahir [1 ]
机构
[1] Charite, Campus Charite Mitte, Klin Strahlenheilkunde, D-10117 Berlin, Germany
[2] Charite, Campus Charite Mitte, Urol Klin, D-10117 Berlin, Germany
[3] Klinikum Ernst von Bergmann gGmbh, Potdsam, Germany
关键词
Prostate cancer; MRI; PI-RADS; Coil; PHASED-ARRAY COILS; MRI; BIOPSY; AGGRESSIVENESS; GUIDELINES; GRADIENT; SCORE;
D O I
10.1016/j.ejrad.2016.03.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To intraindividually compare image quality and diagnostic performance of multiparametric MRI (mpMRI) at 3 T for the detection of prostate cancer (PCa) using a pelvic phased-array coil (PAC) and a combined endorectal and pelvic phased-array coil (ERC-PAC). Methods: Forty-five patients were prospectively included and received mpMRI of the prostate using a PAC and an ERC-PAC during one imaging session. Two radiologists evaluated image quality and the most suspicious lesion according to the PI-RADS scoring system. Results of MRI-TRUS-fusion biopsy of the prostate served as reference standard. Patient comfort and acceptance were assessed using a standardized questionnaire. Results: Overall image quality for T2WI was rated significantly better with an ERC-PAC compared to a PAC (p = 0.0038). The weighted kappa for PI-RADS scores for T2WI and DWI with a PAC and an ERC-PAC was 0.70 and 0.73, respectively. For a PI-RADS sum score including T2WI and DWI the area under the curve with a PAC and an ERC-PAC were 0.95-0.99 and 0.93-0.97, respectively (p = 0.1395). Conclusion: For T2WI and DWI performed at 3 T index PCa lesion identification and evaluation did not differ significantly with both coil setups. Patients preferred MRI without an ERC. Therefore, the use of an ERC may be omitted in a prostate cancer detection setting. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1075 / 1084
页数:10
相关论文
共 24 条
  • [1] [Anonymous], 2015, MR PROST IM REP DAT
  • [2] ESUR prostate MR guidelines 2012
    Barentsz, Jelle O.
    Richenberg, Jonathan
    Clements, Richard
    Choyke, Peter
    Verma, Sadhna
    Villeirs, Geert
    Rouviere, Olivier
    Logager, Vibeke
    Futterer, Jurgen J.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (04) : 746 - 757
  • [3] Evaluation of the Prostate Imaging Reporting and Data System for the Detection of Prostate Cancer by the Results of Targeted Biopsy of the Prostate
    Baur, Alexander D. J.
    Maxeiner, Andreas
    Franiel, Tobias
    Kilic, Ergin
    Huppertz, Alexander
    Schwenke, Carsten
    Hamm, Bernd
    Durmus, Tahir
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (06) : 411 - 420
  • [4] Beyersdorff D, 2003, ROFO-FORTSCHR RONTG, V175, P799
  • [5] Standardization of Multiparametric Prostate MR Imaging Using PI-RADS
    Bomers, Joyce G. R.
    Barentsz, Jelle O.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [6] Washout gradient in dynamic contrast-enhanced MRI is associated with tumor aggressiveness of prostate cancer
    Chen, Yu-Jen
    Chu, Woei-Chyn
    Pu, Yeong-Shiau
    Chueh, Shih-Chieh
    Shun, Chia-Tung
    Tseng, Wen-Yih Isaac
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (04) : 912 - 919
  • [7] Pretreatment evaluation of prostate cancer:: Role of MR imaging and 1H MR spectroscopy
    Claus, FG
    Hricak, H
    Hattery, RR
    [J]. RADIOGRAPHICS, 2004, 24 : S167 - S180
  • [8] Magnetic Resonance Imaging for the Detection, Localisation, and Characterisation of Prostate Cancer: Recommendations from a European Consensus Meeting
    Dickinson, Louise
    Ahmed, Hashim U.
    Allen, Clare
    Barentsz, Jelle O.
    Carey, Brendan
    Futterer, Jurgen J.
    Heijmink, Stijn W.
    Hoskin, Peter J.
    Kirkham, Alex
    Padhani, Anwar R.
    Persad, Raj
    Puech, Philippe
    Punwani, Shonit
    Sohaib, Aslam S.
    Tombal, Bertrand
    Villers, Arnauld
    van der Meulen, Jan
    Emberton, Mark
    [J]. EUROPEAN UROLOGY, 2011, 59 (04) : 477 - 494
  • [9] Technical aspects of MR diffusion imaging of the body
    Dietrich, Olaf
    Biffar, Andreas
    Baur-Melnyk, Andrea
    Reiser, Maximilian F.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (03) : 314 - 322
  • [10] Detection of Prostate Cancer by Real-Time MR/Ultrasound Fusion-Guided Biopsy: 3T MRI and State of the Art Sonography
    Durmus, T.
    Stephan, C.
    Grigoryev, M.
    Diederichs, G.
    Saleh, M.
    Slowinski, T.
    Maxeiner, A.
    Thomas, A.
    Fischer, T.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (05): : 428 - 433