Subaperture Processing-Based Adaptive Beamforming for Photoacoustic Imaging

被引:7
作者
Al Mukaddim, Rashid [1 ,2 ]
Ahmed, Rifat [3 ]
Varghese, Tomy [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
基金
美国国家卫生研究院;
关键词
Beamforming; cardiac photoacoustic (PA) imaging; clutter suppression; coherence factor (CF); delay-and-sum (DAS); PA imaging (PAI); preclinical PAI; subaperture processing; LAG SPATIAL COHERENCE; TO-NOISE RATIO; DUAL APODIZATION; CONTRAST; DELAY; SUM; RECONSTRUCTION; TOMOGRAPHY; ALGORITHM; SPECKLE;
D O I
10.1109/TUFFC.2021.3060371
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Delay-and-sum (DAS) beamformers, when applied to photoacoustic (PA) image reconstruction, produce strong sidelobes due to the absence of transmit focusing. Consequently, DAS PA images are often severely degraded by strong off-axis clutter. For preclinical in vivo cardiac PA imaging, the presence of these noise artifacts hampers the detectability and interpretation of PA signals from the myocardial wall, crucial for studying blood-dominated cardiac pathological information and to complement functional information derived from ultrasound imaging. In this article, we present PA subaperture processing (PSAP), an adaptive beamforming method, to mitigate these image degrading effects. In PSAP, a pair of DAS reconstructed images is formed by splitting the received channel data into two complementary nonoverlapping sub-apertures. Then, a weighting matrix is derived by analyzing the correlation between subaperture beamformed images and multiplied with the full-aperture DAS PA image to reduce sidelobes and incoherent clutter. We validated PSAP using numerical simulation studies using point target, diffuse inclusion and microvasculature imaging, and in vivo feasibility studies on five healthy murine models. Qualitative and quantitative analysis demonstrate improvements in PAI image quality with PSAP compared to DAS and coherence factor weighted DAS (DAS(CF)). PSAP demonstrated improved target detectability with a higher generalized contrast-to-noise (gCNR) ratio in vasculature simulations where PSAP produces 19.61% and 19.53% higher gCNRs than DAS and DAS(CF), respectively. Furthermore, PSAP provided higher image contrast quantified using contrast ratio (CR) (e.g., PSAP produces 89.26% and 11.90% higher CR than DAS and DAS(CF) in vasculature simulations) and improved clutter suppression.
引用
收藏
页码:2336 / 2350
页数:15
相关论文
共 87 条
[41]   MCmatlab: an open-source, user-friendly, MATLAB-integrated three-dimensional Monte Carlo light transport solver with heat diffusion and tissue damage [J].
Marti, Dominik ;
Aasbjerg, Rikke N. ;
Andersen, Peter E. ;
Hansen, Anders K. .
JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (12)
[42]   The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical Imaging [J].
Matrone, Giulia ;
Savoia, Alessandro Stuart ;
Caliano, Giosue ;
Magenes, Giovanni .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (04) :940-949
[43]   An Approach to Unbiased Subsample Interpolation for Motion Tracking [J].
McCormick, Matthew M. ;
Varghese, Tomy .
ULTRASONIC IMAGING, 2013, 35 (02) :76-89
[44]   Image improvement in linear-array photoacoustic imaging using high resolution coherence factor weighting technique [J].
Moein Mozaffarzadeh ;
Bahador Makkiabadi ;
Maryam Basij ;
Mohammad Mehrmohammadi .
BMC Biomedical Engineering, 1 (1)
[45]   Linear-array photoacoustic imaging using minimum variance-based delay multiply and sum adaptive beamforming algorithm [J].
Mozaffarzadeh, Moein ;
Mahloojifar, Ali ;
Orooji, Mahdi ;
Kratkiewicz, Karl ;
Adabi, Saba ;
Nasiriavanaki, Mohammadreza .
JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (02)
[46]   The double-stage delay-multiply-and-sum image reconstruction method improves imaging quality in a LED-based photoacoustic array scanner [J].
Mozaffarzadeh, Moein ;
Hariri, Ali ;
Moore, Colman ;
Jokerst, Jesse, V .
PHOTOACOUSTICS, 2018, 12 :22-29
[47]   Eigenspace-Based Minimum Variance Combined With Delay Multiply and Sum Beamformer: Application to Linear-Array Photoacoustic Imaging [J].
Mozaffarzadeh, Moein ;
Mahloojifar, Ali ;
Periyasamy, Vijitha ;
Pramanik, Manojit ;
Orooji, Mandi .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2019, 25 (01)
[48]   Model-Based Photoacoustic Image Reconstruction using Compressed Sensing and Smoothed L0 Norm [J].
Mozaffarzadeh, Moein ;
Mahloojifar, Ali ;
Nasiriavanaki, Mohammadreza ;
Orooji, Mahdi .
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
[49]   Enhanced linear-array photoacoustic beamforming using modified coherence factor [J].
Mozaffarzadeh, Moein ;
Yan, Yan ;
Mehrmohammadi, Mohammad ;
Makkiabadi, Bahador .
JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (02)
[50]   Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging [J].
Mozaffarzadeh, Moein ;
Mahloojifar, Ali ;
Orooji, Mahdi ;
Adabi, Saba ;
Nasiriavanaki, Mohammadreza .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (01) :31-42