Development of a fast and selective method for the sensitive determination of anatoxin-a in lake waters using liquid chromatography-tandem mass spectrometry and phenylalanine-d5 as internal standard

被引:27
|
作者
Dimitrakopoulos, Ioannis K. [1 ,2 ]
Kaloudis, Triantafyllos S. [3 ]
Hiskia, Anastasia E. [2 ]
Thomaidis, Nikolaos S. [1 ]
Koupparis, Michael A. [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, GR-15771 Athens, Greece
[2] Natl Ctr Sci Res Demokritos, Inst Phys Chem, Lab Catalyt Photocatalyt Proc Solar Energy Enviro, GR-15310 Athens, Greece
[3] Athens Water Supply & Sewerage Co EYDAP SA, Water Qual Control Dept, Organ Micropollutants Lab, Athens 11146, Greece
关键词
Anatoxin-a; Cyanotoxins; Water analysis; LC-ESI-MS/MS; Isotope-labelled internal standard; Porous graphitic carbon SPE; SOLID-PHASE MICROEXTRACTION; GREEK FRESH-WATERS; CYANOBACTERIAL TOXIN; AQUEOUS SAMPLES; FLUORESCENCE DETECTION; DEGRADATION-PRODUCTS; HOMOANATOXIN-A; EXTRACTION; NEUROTOXIN; TOXICITY;
D O I
10.1007/s00216-010-3727-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Anatoxin-a is a potent alkaloid neurotoxin produced by a number of cyanobacterial species and released in freshwaters during cyanobacterial blooms. Its high toxicity is responsible for several incidents of lethal intoxications of birds and mammals around the world; therefore anatoxin-a has to be regarded as a health risk and its concentration in lakes and water reservoirs should be monitored. Phenylalanine is a natural amino acid, also present in freshwaters, isobaric to anatoxin-a, with a very similar fragmentation pattern and LC retention. Since misidentification of phenylalanine as anatoxin-a has been reported in forensic investigations, special care must be taken in order to selectively determine traces of anatoxin-a in the presence of naturally occurring phenylalanine. A fast LC tandem MS method was developed by using a 1.8 mu m 50 x 2.1 mm C18 column for the separation of anatoxin-a and phenylalanine, achieving a 3-min analysis time. Isotopically labelled phenylalanine-d(5) was employed as internal standard to compensate for electrospray ion suppression and sample preconcentration losses. Both compounds were preconcentrated 1,000-fold on a porous graphitic carbon solid-phase extraction (SPE) cartridge after adjustment of sample pH to 10.5. The method was validated by using lake water spiked at four different levels from 0.01 to 1 mu g L-1. Anatoxin-a recovery ranged from 73 to 97%, intra-day precision (RSD%) ranged from 4.2 to 5.9, while inter-day precision (RSD%) ranged from 4.2 to 9.1%. Limits of detection and quantification were 0.65 and 1.96 ng L-1 respectively. The method was successfully applied for the detection of anatoxin-a in Greek lakes at concentrations ranging from less than 0.6 to 9.1 ng L-1.
引用
收藏
页码:2245 / 2252
页数:8
相关论文
共 50 条
  • [21] Stability evaluation and sensitive determination of antiviral drug, valacyclovir and its metabolite acyclovir in human plasma by a rapid liquid chromatography-tandem mass spectrometry method
    Yadav, Manish
    Upadhyay, Vivek
    Singhal, Puran
    Goswami, Sailendra
    Shrivastav, Pranav S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (8-9): : 680 - 688
  • [22] Determination of 5-fluorouracil and dihydrofluorouracil levels by using a liquid chromatography-tandem mass spectrometry method for evaluation of dihydropyrimidine dehydrogenase enzyme activity
    Serdar, Muhittin A.
    Sertoglu, Erdim
    Uyanik, Metin
    Tapan, Serkan
    Akin, Okhan
    Cihan, Murat
    CANCER CHEMOTHERAPY AND PHARMACOLOGY, 2011, 68 (02) : 525 - 529
  • [23] Development of an extraction method for the determination of avermectins in soil using supercritical CO2 modified with ethanol and liquid chromatography-tandem mass spectrometry
    Park, Jong-Hyouk
    Choi, Jeong-Heui
    Abd El-Aty, A. M.
    Park, Joon-Seong
    Kim, Bo Mi
    Na, Tae-Woong
    Park, Ki Hun
    Yang, Angel
    Rahman, Md. Musfiqur
    Shim, Jae-Han
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (01) : 148 - 155
  • [24] Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of nine corticosteroid residues in bovine liver samples
    Dusi, Guglielmo
    Gasparini, Mara
    Curatolo, Michele
    Assini, Walter
    Bozzoni, Eros
    Tognoli, Nadia
    Ferretti, Enrica
    ANALYTICA CHIMICA ACTA, 2011, 700 (1-2) : 49 - 57
  • [25] Development and Validation of the New Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Unbound Tacrolimus in the Plasma Ultrafiltrate of Transplant Recipients
    Bodnar-Broniarczyk, Magdalena
    Warzyszynska, Karola
    Czerwinska, Katarzyna
    Marszalek, Dorota
    Dziewa, Natalia
    Kosieradzki, Maciej
    Pawinski, Tomasz
    PHARMACEUTICS, 2022, 14 (03)
  • [26] Ultra Fast Liquid Chromatography-Tandem Mass Spectrometry Routine Method for Simultaneous Determination of Cyclosporin A, Tacrolimus, Sirolimus, and Everolimus in Whole Blood Using Deuterated Internal Standards for Cyclosporin A and Everolimus
    Meinitzer, Andreas
    Gartner, Gabriele
    Pilz, Stefan
    Stettin, Mariana
    THERAPEUTIC DRUG MONITORING, 2010, 32 (01) : 61 - 66
  • [27] Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry
    Novakova, Lucie
    Gottvald, Tomas
    Vickova, Hana
    Trejtnar, Frantisek
    Mandikova, Jana
    Solich, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 : 237 - 243
  • [28] Determination of toxic organic pollutants in fine particulate matter using selective pressurized liquid extraction and gas chromatography-tandem mass spectrometry
    Kim, Injeong
    Lee, Sunhong
    Kim, Sang Don
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1590 : 39 - 46
  • [29] A rapid liquid chromatography-tandem mass spectrometry method for the analysis of urinary 5-hydroxyindoleacetic acid (5-HIAA) that incorporates a 13C-labelled internal standard
    Grant, Kirsten M.
    Livie, Craig
    Smith, Karen
    Leung, Chui Ha
    Johnston, Susan
    ANNALS OF CLINICAL BIOCHEMISTRY, 2021, 58 (06) : 622 - 631
  • [30] A simple, rapid and sensitive liquid chromatography-tandem mass spectrometry method for the determination of dienogest in human plasma and its pharmacokinetic applications under fasting
    Pallapothu, Leela Mohan Kumar
    Batta, Neelima
    Pigili, Ravi Kumar
    Yejella, Rajendra Prasad
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (02) : 194 - 201