Surface stress sensors for detection of chemical and biological species

被引:0
作者
Kang, K. [1 ]
Marquardt, J. [1 ]
Shrotriya, P. [1 ]
机构
[1] Iowa State Univ, Dept Mech Engn, 2025 Black, Ames, IA 50011 USA
来源
SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2007, PTS 1 AND 2 | 2007年 / 6529卷
基金
美国国家科学基金会;
关键词
D O I
10.1117/12.715958
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
A miniature differential surface stress sensor consisting of two adjacent micromachined cantilevers (a sensing/reference pair) is developed for detection of chemical and biological species. Presence of analyte species is detected by measuring the differential surface stress associated with adsorption/absorption of chemical species on sensing cantilever. A novel interferometric technique is utilized to measure the differential surface stress induced bending of sensing cantilever with respect to reference cantilever. Sensor performance is characterized through measurement of surface stress associated with formation of alkanethiol self-assembled monolayers (SAMs) on gold coated sensing cantilever. Chemisorptions and self-assembly of alkanethiol molecules onto the gold-coated cantilever surface leads to development of compressive surface stress. Magnitude of measured surface stress compares well with data reported in literature.
引用
收藏
页数:6
相关论文
共 9 条
  • [1] Surface stress in the self-assembly of alkanethiols on gold
    Berger, R
    Delamarche, E
    Lang, HP
    Gerber, C
    Gimzewski, JK
    Meyer, E
    Guntherodt, HJ
    [J]. SCIENCE, 1997, 276 (5321) : 2021 - 2024
  • [2] Surface stress, kinetics, and structure of alkanethiol self-assembled monolayers
    Godin, M
    Williams, PJ
    Tabard-Cossa, V
    Laroche, O
    Beaulieu, LY
    Lennox, RB
    Grütter, P
    [J]. LANGMUIR, 2004, 20 (17) : 7090 - 7096
  • [3] Quantitative surface stress measurements using a microcantilever
    Godin, M
    Tabard-Cossa, V
    Grütter, P
    Williams, P
    [J]. APPLIED PHYSICS LETTERS, 2001, 79 (04) : 551 - 553
  • [4] A novel self-assembled monolayer (SAM) coated microcantilever for low level caesium detection
    Ji, HF
    Finot, E
    Dabestani, R
    Thundat, T
    Brown, GM
    Britt, PF
    [J]. CHEMICAL COMMUNICATIONS, 2000, (06) : 457 - 458
  • [5] Changes in surface stress at the liquid/solid interface measured with a microcantilever
    Raiteri, R
    Butt, HJ
    Grattarola, M
    [J]. ELECTROCHIMICA ACTA, 2000, 46 (2-3) : 157 - 163
  • [6] Nanomechanical effect of enzymatic manipulation of DNA on microcantilever surfaces
    Stevenson, KA
    Mehta, A
    Sachenko, P
    Hansen, KM
    Thundat, T
    [J]. LANGMUIR, 2002, 18 (23) : 8732 - 8736
  • [7] THERMAL AND AMBIENT-INDUCED DEFLECTIONS OF SCANNING FORCE MICROSCOPE CANTILEVERS
    THUNDAT, T
    WARMACK, RJ
    CHEN, GY
    ALLISON, DP
    [J]. APPLIED PHYSICS LETTERS, 1994, 64 (21) : 2894 - 2896
  • [8] DETECTION OF MERCURY-VAPOR USING RESONATING MICROCANTILEVERS
    THUNDAT, T
    WACHTER, EA
    SHARP, SL
    WARMACK, RJ
    [J]. APPLIED PHYSICS LETTERS, 1995, 66 (13) : 1695 - 1697
  • [9] ULMAN A, 1991, INTRO ULTRATHIN ORGA, P442