Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial

被引:17
|
作者
Sariali, Elhadi [1 ,2 ,3 ]
Kajetanek, Charles [1 ]
Catonne, Yves [1 ]
机构
[1] Hop Univ La Pitie Salpetriere Charles Foix, AP HP, F-75013 Paris, France
[2] UPMC Univ Paris 06, CNRS, INSERM, Sorbonne Univ,Lab Imagerie Biomed, F-75006 Paris, France
[3] Pitie Salpetriere Teaching Hosp, Hip & Knee Arthroplasty Dept, 47-83 Bd Hop, F-75013 Paris, France
关键词
3D planning; Custom; Knee; Arthroplasty; Patient specific; PATIENT-SPECIFIC INSTRUMENTATION; ALIGNMENT; IMPROVE;
D O I
10.1007/s00264-019-04357-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Incorrect positioning of components during total knee arthroplasty (TKA) increases the risk of pain, instability, and early revision. The purpose of this study was to compare 3D planning-assisted and a conventional system for TKA positioning. We hypothesized that the use of three-dimensional CT-scan planning and custom cutting guides would increase the accuracy of component positioning. Methods A randomized, controlled, prospective study of two groups was performed. In one group, patient-specific custom cutting guides (PSCG) were used for component positioning based on 3D CT-scan planning. In the control group, TKA was performed with a conventional ancillary system. The components' positioning angles were measured on 3D reconstructions. The main evaluation criterion was the percentage of outliers outside of a target zone of +/- 3 degrees for the coronal positioning of the femoral component. Results Eighty patients were included. The percentage of outliers for the femoral component was significantly lower in the 3D-guided group (1 patient) compared to the control group (7 patients p = 0.02). The coronal femoral angle was restored with greater accuracy in the 3D-assisted group (- 0.1 degrees +/- 1.4 degrees) compared to the control group (1.6 degrees +/- 2.5 degrees). Surgery was significantly shorter in the 3D group. The clinical outcomes were better in the 3D group at the two year follow-up with fewer failures and a lower standard deviation in IKS scores. Conclusion The use of a 3D planning and custom guides can improve TKA component positioning by increasing the accuracy of implants alignment and reducing the percentage of outliers. The same benefit was not demonstrated for the global knee alignment and the clinical scores with no indisputable clinical advantage for the PSCG.
引用
收藏
页码:2529 / 2538
页数:10
相关论文
共 50 条
  • [41] Response to Letter to the Editor on "Interobserver and Intraobserver Reliability of Computed Tomography-Based Three-Dimensional Preoperative Planning for Primary Total Knee Arthroplasty" Reply
    Miura, Michiaki
    Hagiwara, Shigeo
    JOURNAL OF ARTHROPLASTY, 2018, 33 (06): : 1981 - 1982
  • [42] A randomized controlled trial of three-dimensional versus two-dimensional imaging system on duration of surgery and mental workload for laparoscopic gastropexies in dogs
    Balsa, Ingrid M.
    Giuffrida, Michelle A.
    Mayhew, Philipp D.
    VETERINARY SURGERY, 2021, 50 (05) : 944 - 953
  • [43] Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study
    Yamada, Kazuki
    Endo, Hirosuke
    Tetsunaga, Tomonori
    Miyake, Takamasa
    Sanki, Tomoaki
    Ozaki, Toshifumi
    JOURNAL OF ARTHROPLASTY, 2018, 33 (01): : 136 - 143
  • [44] Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers
    van Steenberghe, D
    Malevez, C
    Van Cleynenbreugel, J
    Serhal, CB
    Dhoore, E
    Schutyser, F
    Suetens, P
    Jacobs, R
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (01) : 131 - 136
  • [45] Enhancing Transjugular Intrahepatic Portosystemic Shunt Puncture by Using Three-dimensional Path Planning Based on the Back Projection of Two Two-dimensional Portographs
    Adamus, Ralf
    Pfister, Marcus
    Loose, Reinhard W. R.
    RADIOLOGY, 2009, 251 (02) : 543 - 547
  • [46] Comparison of the planning target volume based on three-dimensional CT and four-dimensional CT images of non-small-cell lung cancer
    Li, Feng Xiang
    Bin Li, Jian
    Zhang, Ying Jie
    Liu, Tong Hai
    Tian, Shi Yu
    Xu, Min
    Shang, Dong Ping
    Ma, Chang Sheng
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) : 176 - 180
  • [47] Comparison of the Planning Target Volume Based on Three-dimensional CT and Four-dimensional CT Images of Non-small Cell Lung Cancer
    Li, F.
    Li, J.
    Zhang, Y.
    Xu, M.
    Shao, Q.
    Fan, T.
    Tian, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S791 - S791
  • [48] Comparison of scoliosis measurements based on three-dimensional vertebra vectors and conventional two-dimensional measurements: advantages in evaluation of prognosis and surgical results
    Tamás Illés
    Szabolcs Somoskeöy
    European Spine Journal, 2013, 22 : 1255 - 1263
  • [49] Comparison of scoliosis measurements based on three-dimensional vertebra vectors and conventional two-dimensional measurements: advantages in evaluation of prognosis and surgical results
    Illes, Tamas
    Somoskeoey, Szabolcs
    EUROPEAN SPINE JOURNAL, 2013, 22 (06) : 1255 - 1263
  • [50] Comparison of a novel handheld accelerometer-based navigation system and conventional instrument for performing distal femoral resection in total knee arthroplasty: a randomized controlled trial
    Xu, Xingquan
    Liu, Peilai
    Yuan, Zhenfeng
    Wang, Dawei
    Lu, Qunshan
    Zhang, Zhe
    Jiang, Qing
    Shi, Dongquan
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (22)