Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial

被引:17
|
作者
Sariali, Elhadi [1 ,2 ,3 ]
Kajetanek, Charles [1 ]
Catonne, Yves [1 ]
机构
[1] Hop Univ La Pitie Salpetriere Charles Foix, AP HP, F-75013 Paris, France
[2] UPMC Univ Paris 06, CNRS, INSERM, Sorbonne Univ,Lab Imagerie Biomed, F-75006 Paris, France
[3] Pitie Salpetriere Teaching Hosp, Hip & Knee Arthroplasty Dept, 47-83 Bd Hop, F-75013 Paris, France
关键词
3D planning; Custom; Knee; Arthroplasty; Patient specific; PATIENT-SPECIFIC INSTRUMENTATION; ALIGNMENT; IMPROVE;
D O I
10.1007/s00264-019-04357-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Incorrect positioning of components during total knee arthroplasty (TKA) increases the risk of pain, instability, and early revision. The purpose of this study was to compare 3D planning-assisted and a conventional system for TKA positioning. We hypothesized that the use of three-dimensional CT-scan planning and custom cutting guides would increase the accuracy of component positioning. Methods A randomized, controlled, prospective study of two groups was performed. In one group, patient-specific custom cutting guides (PSCG) were used for component positioning based on 3D CT-scan planning. In the control group, TKA was performed with a conventional ancillary system. The components' positioning angles were measured on 3D reconstructions. The main evaluation criterion was the percentage of outliers outside of a target zone of +/- 3 degrees for the coronal positioning of the femoral component. Results Eighty patients were included. The percentage of outliers for the femoral component was significantly lower in the 3D-guided group (1 patient) compared to the control group (7 patients p = 0.02). The coronal femoral angle was restored with greater accuracy in the 3D-assisted group (- 0.1 degrees +/- 1.4 degrees) compared to the control group (1.6 degrees +/- 2.5 degrees). Surgery was significantly shorter in the 3D group. The clinical outcomes were better in the 3D group at the two year follow-up with fewer failures and a lower standard deviation in IKS scores. Conclusion The use of a 3D planning and custom guides can improve TKA component positioning by increasing the accuracy of implants alignment and reducing the percentage of outliers. The same benefit was not demonstrated for the global knee alignment and the clinical scores with no indisputable clinical advantage for the PSCG.
引用
收藏
页码:2529 / 2538
页数:10
相关论文
共 50 条
  • [31] A higher reliability with a computed tomography scan-based three dimensional technique than with a two dimensional measurement for lower limb discrepancy in total hip arthroplasty planning
    Sariali, Elhadi
    Mueller, Matthias
    Klouche, Shahnaz
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (12) : 3129 - 3137
  • [32] A higher reliability with a computed tomography scan-based three dimensional technique than with a two dimensional measurement for lower limb discrepancy in total hip arthroplasty planning
    Elhadi Sariali
    Matthias Mueller
    Shahnaz Klouche
    International Orthopaedics, 2021, 45 : 3129 - 3137
  • [33] Comparison of planning target volumes based on three-dimensional and four-dimensional CT imaging of thoracic esophageal cancer
    Wang, Wei
    Li, Jianbin
    Zhang, Yingjie
    Shao, Qian
    Xu, Min
    Fan, Tingyong
    Wang, Jinzhi
    ONCOTARGETS AND THERAPY, 2016, 9 : 4785 - 4791
  • [34] Three-Dimensional CT for Preprocedural Planning of PCI for Ostial Right Coronary Artery Lesions: A Randomized Controlled Pilot Trial
    van den Buijs, Deborah M. F.
    Poels, Ella M.
    Willems, Endry
    Cottens, Daan
    Dotremont, Kevin
    De Leener, Karen
    Meekers, Evelyne
    Ferdinande, Bert
    Vrolix, Mathias
    Dens, Joseph
    Ameloot, Koen
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2025, 18 (02)
  • [35] Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides
    Lazaros Vlachopoulos
    Andreas Schweizer
    Matthias Graf
    Ladislav Nagy
    Philipp Fürnstahl
    BMC Musculoskeletal Disorders, 16
  • [36] Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides
    Vlachopoulos, Lazaros
    Schweizer, Andreas
    Graf, Matthias
    Nagy, Ladislav
    Fuernstahl, Philipp
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [37] Accuracy and reproducibility of two-dimensional computed tomography-based positioning of femoral component rotational alignment in preoperative planning for total knee arthroplasty
    Kun Liu
    Yuandong Liu
    Zongqing Fan
    Donglin Fu
    Journal of Orthopaedic Surgery and Research, 18
  • [38] Accuracy and reproducibility of two-dimensional computed tomography-based positioning of femoral component rotational alignment in preoperative planning for total knee arthroplasty
    Liu, Kun
    Liu, Yuandong
    Fan, Zongqing
    Fu, Donglin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [39] Is Valgus Cut Angle Based on Radiographic Measurements in Total Knee Arthroplasty Really Inaccurate? A Comparison of Two- and Three-Dimensional Measurements
    Liu, LiMing
    Lei, Kai
    Chen, Xin
    Fan, HuaQuan
    Yang, Liu
    Guo, Lin
    JOURNAL OF KNEE SURGERY, 2022, 35 (14) : 1563 - 1570
  • [40] Differences between two-dimensional (2D) weight-bearing and three-dimensional (3D) non-weight-bearing planning in total knee arthroplasty (TKA)
    Pfluger, Patrick
    Hodel, Sandro
    Zimmermann, Stefan M.
    Knechtle, Svenja
    Vlachopoulos, Lazaros
    Fucentese, Sandro F.
    SWISS MEDICAL WEEKLY, 2023, 153 : 32S - 32S