Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial

被引:17
|
作者
Sariali, Elhadi [1 ,2 ,3 ]
Kajetanek, Charles [1 ]
Catonne, Yves [1 ]
机构
[1] Hop Univ La Pitie Salpetriere Charles Foix, AP HP, F-75013 Paris, France
[2] UPMC Univ Paris 06, CNRS, INSERM, Sorbonne Univ,Lab Imagerie Biomed, F-75006 Paris, France
[3] Pitie Salpetriere Teaching Hosp, Hip & Knee Arthroplasty Dept, 47-83 Bd Hop, F-75013 Paris, France
关键词
3D planning; Custom; Knee; Arthroplasty; Patient specific; PATIENT-SPECIFIC INSTRUMENTATION; ALIGNMENT; IMPROVE;
D O I
10.1007/s00264-019-04357-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Incorrect positioning of components during total knee arthroplasty (TKA) increases the risk of pain, instability, and early revision. The purpose of this study was to compare 3D planning-assisted and a conventional system for TKA positioning. We hypothesized that the use of three-dimensional CT-scan planning and custom cutting guides would increase the accuracy of component positioning. Methods A randomized, controlled, prospective study of two groups was performed. In one group, patient-specific custom cutting guides (PSCG) were used for component positioning based on 3D CT-scan planning. In the control group, TKA was performed with a conventional ancillary system. The components' positioning angles were measured on 3D reconstructions. The main evaluation criterion was the percentage of outliers outside of a target zone of +/- 3 degrees for the coronal positioning of the femoral component. Results Eighty patients were included. The percentage of outliers for the femoral component was significantly lower in the 3D-guided group (1 patient) compared to the control group (7 patients p = 0.02). The coronal femoral angle was restored with greater accuracy in the 3D-assisted group (- 0.1 degrees +/- 1.4 degrees) compared to the control group (1.6 degrees +/- 2.5 degrees). Surgery was significantly shorter in the 3D group. The clinical outcomes were better in the 3D group at the two year follow-up with fewer failures and a lower standard deviation in IKS scores. Conclusion The use of a 3D planning and custom guides can improve TKA component positioning by increasing the accuracy of implants alignment and reducing the percentage of outliers. The same benefit was not demonstrated for the global knee alignment and the clinical scores with no indisputable clinical advantage for the PSCG.
引用
收藏
页码:2529 / 2538
页数:10
相关论文
共 50 条
  • [21] A prospective randomized controlled trial comparing CT- based planning with conventional total hip arthroplasty versus robotic arm- assisted total hip arthroplasty
    Fontalis, A.
    Kayani, B.
    Plastow, R.
    Giebaly, D. E.
    Tahmassebi, J.
    Haddad, I. C.
    Chambers, A.
    Mancino, F.
    Konan, S.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2024, 106B (04): : 324 - 335
  • [22] Brachytherapy Plan Quality Evaluation of Three-Dimensional Imaging Based Inverse Planning as Compared to Two-Dimensional Imaging Standard Load Planning
    Herman, T. De La Fuente
    Schnell, E.
    Thompson, S.
    Ahmad, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E354 - E354
  • [23] Artificial intelligence-based three-dimensional templating for total joint arthroplasty planning: a scoping review
    Garcia, Ausberto Velasquez
    Bukowiec, Lainey G.
    Yang, Linjun
    Nishikawa, Hiroki
    Fitzsimmons, James S.
    Larson, A. Noelle
    Taunton, Michael J.
    Sanchez-Sotelo, Joaquin
    O'Driscoll, Shawn W.
    Wyles, Cody C.
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (04) : 997 - 1010
  • [24] Comparison of robot-assisted and conventional total knee arthroplasty: A controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment
    Moon, Young-Wan
    Ha, Chul-Won
    Do, Kwan-Hong
    Kim, Chang-Young
    Han, Jeong-Hoon
    Na, Sang-Eun
    Lee, Choong-Hee
    Kim, Jae-Gyoon
    Park, Youn-Soo
    COMPUTER AIDED SURGERY, 2012, 17 (02) : 86 - 95
  • [25] Comparison of the Planning Target Volume Based on Three-Dimensional CT and Four-Dimensional CT Images of Thoracic Esophageal Cancer
    Wang, W.
    Li, J.
    Shao, Q.
    Zhang, Y.
    Liu, S.
    Xu, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E161 - E162
  • [26] Comparison Of The Planning Target Volume Based On Three-dimensional CT And Four-dimensional CT Images Of Thoracic Esophageal Cancer
    Wang, W.
    Li, J.
    Zhang, Y.
    Fan, T.
    Qi, H.
    Xing, J.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S307 - S307
  • [27] Letter to the Editor on "Interobserver and Intraobserver Reliability of Computed Tomography-Based Three-Dimensional Preoperative Planning for Primary Total Knee Arthroplasty"
    Vaishya, Raju
    Vijay, Vipul
    Agarwal, Amit K.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (06): : 1980 - 1981
  • [28] Preoperative CT-Based Three-Dimensional Templating in Robot-Assisted Total Knee Arthroplasty More Accurately Predicts Implant Sizes than Two-Dimensional Templating
    Pietrzak, J. R. T.
    Rowan, F. E.
    Kayani, B.
    Donaldson, M. J.
    Huq, S. S.
    Haddad, F. S.
    JOURNAL OF KNEE SURGERY, 2019, 32 (07) : 642 - 648
  • [29] Dosimetric Comparison between Three-Dimensional Magnetic Resonance Imaging-Guided and Conventional Two-Dimensional Point A-Based Intracavitary Brachytherapy Planning for Cervical Cancer
    Ren, Juan
    Yuan, Wei
    Wang, Ruihua
    Wang, Qiuping
    Li, Yi
    Xue, Chaofan
    Yan, Yanli
    Ma, Xiaowei
    Tan, Li
    Liu, Zi
    PLOS ONE, 2016, 11 (09):
  • [30] Three-dimensional-based native alignment phenotype classification system: Description for use in planning for deformities during total knee arthroplasty
    Marchand, Robert
    Shul, Craig
    Hameed, Daniel
    Dubin, Jeremy
    Roche, Martin
    Bowes, Mike
    Scholl, Laura
    Gutowski, Todd
    Mont, A. Michael
    JOURNAL OF ORTHOPAEDICS, 2024, 54 : 163 - 167