Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial

被引:17
|
作者
Sariali, Elhadi [1 ,2 ,3 ]
Kajetanek, Charles [1 ]
Catonne, Yves [1 ]
机构
[1] Hop Univ La Pitie Salpetriere Charles Foix, AP HP, F-75013 Paris, France
[2] UPMC Univ Paris 06, CNRS, INSERM, Sorbonne Univ,Lab Imagerie Biomed, F-75006 Paris, France
[3] Pitie Salpetriere Teaching Hosp, Hip & Knee Arthroplasty Dept, 47-83 Bd Hop, F-75013 Paris, France
关键词
3D planning; Custom; Knee; Arthroplasty; Patient specific; PATIENT-SPECIFIC INSTRUMENTATION; ALIGNMENT; IMPROVE;
D O I
10.1007/s00264-019-04357-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Incorrect positioning of components during total knee arthroplasty (TKA) increases the risk of pain, instability, and early revision. The purpose of this study was to compare 3D planning-assisted and a conventional system for TKA positioning. We hypothesized that the use of three-dimensional CT-scan planning and custom cutting guides would increase the accuracy of component positioning. Methods A randomized, controlled, prospective study of two groups was performed. In one group, patient-specific custom cutting guides (PSCG) were used for component positioning based on 3D CT-scan planning. In the control group, TKA was performed with a conventional ancillary system. The components' positioning angles were measured on 3D reconstructions. The main evaluation criterion was the percentage of outliers outside of a target zone of +/- 3 degrees for the coronal positioning of the femoral component. Results Eighty patients were included. The percentage of outliers for the femoral component was significantly lower in the 3D-guided group (1 patient) compared to the control group (7 patients p = 0.02). The coronal femoral angle was restored with greater accuracy in the 3D-assisted group (- 0.1 degrees +/- 1.4 degrees) compared to the control group (1.6 degrees +/- 2.5 degrees). Surgery was significantly shorter in the 3D group. The clinical outcomes were better in the 3D group at the two year follow-up with fewer failures and a lower standard deviation in IKS scores. Conclusion The use of a 3D planning and custom guides can improve TKA component positioning by increasing the accuracy of implants alignment and reducing the percentage of outliers. The same benefit was not demonstrated for the global knee alignment and the clinical scores with no indisputable clinical advantage for the PSCG.
引用
收藏
页码:2529 / 2538
页数:10
相关论文
共 50 条
  • [11] Comparison of post-operative three-dimensional and two-dimensional evaluation of component position for total knee arthroplasty
    Tanifuji, Osamu
    Mochizuki, Tomoharu
    Yamagiwa, Hiroshi
    Sato, Takashi
    Watanabe, Satoshi
    Hijikata, Hiroki
    Kawashima, Hiroyuki
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [12] Accuracy of Implant Placement Based on Three-Dimensional Preoperative Planning in Total Elbow Arthroplasty
    Matsuo, Tomoki
    Iwamoto, Takuji
    Kiyota, Yasuhiro
    Suzuki, Taku
    Matsumura, Noboru
    Sato, Kazuki
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2024, 29 (05): : 397 - 407
  • [13] Computed tomography-based three-dimensional preoperative planning for total wrist arthroplasty
    Sugiura, Yutaro
    Iwamoto, Takuji
    Suzuki, Taku
    Kimura, Hiroo
    Matsumura, Noboru
    Sato, Kazuki
    Nakamura, Masaya
    Matsumoto, Morio
    MODERN RHEUMATOLOGY CASE REPORTS, 2020, 4 (02) : 208 - 211
  • [14] Interobserver and Intraobserver Reliability of Computed Tomography-Based Three-Dimensional Preoperative Planning for Primary Total Knee Arthroplasty
    Miura, Michiaki
    Hagiwara, Shigeo
    Nakamura, Junichi
    Wako, Yasushi
    Kawarai, Yuya
    Ohtori, Seiji
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05): : 1572 - 1578
  • [15] The Accuracy of Computed Tomography-Based, Three-Dimensional Implant Planning in Robotic-Assisted Total Knee Arthroplasty
    Marchand, Kevin B.
    Salem, Hytham S.
    Mathew, Kevin K.
    Harwin, Steven F.
    Mont, Michael A.
    Marchand, Robert C.
    JOURNAL OF KNEE SURGERY, 2022, 35 (14) : 1587 - 1594
  • [16] Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating
    Sariali, E.
    Mauprivez, R.
    Khiami, F.
    Pascal-Mousselard, H.
    Catonne, Y.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (02) : 151 - 158
  • [17] Comparison of three-versus two-dimensional pre-operative planning for total hip arthroplasty
    Crutcher, James P.
    Hameed, Daniel
    Dubin, Jeremy
    Mont, Michael A.
    Mont, Michael
    JOURNAL OF ORTHOPAEDICS, 2024, 47 : 100 - 105
  • [18] A Path Planning Algorithm of Automobile Crane Based on Two-dimensional Mapping of Three-dimensional Object
    An Jianqi
    Wang Ling
    He Yong
    Wu Min
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 5982 - 5987
  • [19] Accuracy of computed tomography-based three-dimensional preoperative planning for total wrist arthroplasty
    Matsuo, Tomoki
    Iwamoto, Takuji
    Suzuki, Taku
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2023, 48 (05) : 476 - 478
  • [20] Artificial intelligence–based three-dimensional templating for total joint arthroplasty planning: a scoping review
    Ausberto Velasquez Garcia
    Lainey G. Bukowiec
    Linjun Yang
    Hiroki Nishikawa
    James S. Fitzsimmons
    A. Noelle Larson
    Michael J. Taunton
    Joaquin Sanchez-Sotelo
    Shawn W. O’Driscoll
    Cody C. Wyles
    International Orthopaedics, 2024, 48 : 997 - 1010