Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial

被引:18
作者
Sariali, Elhadi [1 ,2 ,3 ]
Kajetanek, Charles [1 ]
Catonne, Yves [1 ]
机构
[1] Hop Univ La Pitie Salpetriere Charles Foix, AP HP, F-75013 Paris, France
[2] UPMC Univ Paris 06, CNRS, INSERM, Sorbonne Univ,Lab Imagerie Biomed, F-75006 Paris, France
[3] Pitie Salpetriere Teaching Hosp, Hip & Knee Arthroplasty Dept, 47-83 Bd Hop, F-75013 Paris, France
关键词
3D planning; Custom; Knee; Arthroplasty; Patient specific; PATIENT-SPECIFIC INSTRUMENTATION; ALIGNMENT; IMPROVE;
D O I
10.1007/s00264-019-04357-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Incorrect positioning of components during total knee arthroplasty (TKA) increases the risk of pain, instability, and early revision. The purpose of this study was to compare 3D planning-assisted and a conventional system for TKA positioning. We hypothesized that the use of three-dimensional CT-scan planning and custom cutting guides would increase the accuracy of component positioning. Methods A randomized, controlled, prospective study of two groups was performed. In one group, patient-specific custom cutting guides (PSCG) were used for component positioning based on 3D CT-scan planning. In the control group, TKA was performed with a conventional ancillary system. The components' positioning angles were measured on 3D reconstructions. The main evaluation criterion was the percentage of outliers outside of a target zone of +/- 3 degrees for the coronal positioning of the femoral component. Results Eighty patients were included. The percentage of outliers for the femoral component was significantly lower in the 3D-guided group (1 patient) compared to the control group (7 patients p = 0.02). The coronal femoral angle was restored with greater accuracy in the 3D-assisted group (- 0.1 degrees +/- 1.4 degrees) compared to the control group (1.6 degrees +/- 2.5 degrees). Surgery was significantly shorter in the 3D group. The clinical outcomes were better in the 3D group at the two year follow-up with fewer failures and a lower standard deviation in IKS scores. Conclusion The use of a 3D planning and custom guides can improve TKA component positioning by increasing the accuracy of implants alignment and reducing the percentage of outliers. The same benefit was not demonstrated for the global knee alignment and the clinical scores with no indisputable clinical advantage for the PSCG.
引用
收藏
页码:2529 / 2538
页数:10
相关论文
共 21 条
[1]   Can a Single-Use and Patient-Specific Instrumentation Be Reliably Used in Primary Total Knee Arthroplasty? A Multicenter Controlled Study [J].
Abane, Laurent ;
Zaoui, Amine ;
Anract, Philippe ;
Lefevre, Nicolas ;
Herman, Serge ;
Hamadouche, Moussa .
JOURNAL OF ARTHROPLASTY, 2018, 33 (07) :2111-2118
[2]   Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA [J].
Anderl, Werner ;
Pauzenberger, Leo ;
Koeblinger, Roman ;
Kiesselbach, Gabriele ;
Brandl, Georg ;
Laky, Brenda ;
Kriegleder, Bernhard ;
Heuberer, Philipp ;
Schwameis, Eva .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (01) :102-111
[3]  
Baker Paul N, 2012, J Bone Joint Surg Am, V94, pe126
[4]  
Boonen B, 2015, KNEE SURG SPORT TR A, V25, P2809
[5]   A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement [J].
Chareancholvanich, K. ;
Narkbunnam, R. ;
Pornrattanamaneewong, C. .
BONE & JOINT JOURNAL, 2013, 95B (03) :354-359
[6]   Conventional versus computer-assisted surgery in total knee arthroplasty: comparison at ten years follow-up [J].
d'Amato, Michele ;
Ensini, Andrea ;
Leardini, Alberto ;
Barbadoro, Paolo ;
Illuminati, Andrea ;
Belvedere, Claudio .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) :1355-1363
[7]   Three-dimensional analysis of accuracy of component positioning in total knee arthroplasty with patient specific and conventional instruments: A randomized controlled trial [J].
De Vloo, Raf ;
Pellikaan, Pim ;
Dhollander, Aad ;
Vander Sloten, Jos .
KNEE, 2017, 24 (06) :1469-1477
[8]   3D templating and patient-specific cutting guides (Knee-Plan®) in total knee arthroplasty: Postoperative CT-based assessment of implant positioning [J].
Franceschi, J. -P. ;
Sbihi, A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (06) :S281-S286
[9]  
Hamilton WG, 2014, J ARTHROPLASTY, V29, P1508, DOI 10.1016/j.arth.2014.01.029
[10]   Predisposing factors which are relevant for the clinical outcome after revision total knee arthroplasty [J].
Hardeman, Francois ;
Londers, Jurgen ;
Favril, Alexander ;
Witvrouw, Erik ;
Bellemans, Johan ;
Victor, Jan .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (06) :1049-1056