Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial

被引:17
|
作者
Sariali, Elhadi [1 ,2 ,3 ]
Kajetanek, Charles [1 ]
Catonne, Yves [1 ]
机构
[1] Hop Univ La Pitie Salpetriere Charles Foix, AP HP, F-75013 Paris, France
[2] UPMC Univ Paris 06, CNRS, INSERM, Sorbonne Univ,Lab Imagerie Biomed, F-75006 Paris, France
[3] Pitie Salpetriere Teaching Hosp, Hip & Knee Arthroplasty Dept, 47-83 Bd Hop, F-75013 Paris, France
关键词
3D planning; Custom; Knee; Arthroplasty; Patient specific; PATIENT-SPECIFIC INSTRUMENTATION; ALIGNMENT; IMPROVE;
D O I
10.1007/s00264-019-04357-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Incorrect positioning of components during total knee arthroplasty (TKA) increases the risk of pain, instability, and early revision. The purpose of this study was to compare 3D planning-assisted and a conventional system for TKA positioning. We hypothesized that the use of three-dimensional CT-scan planning and custom cutting guides would increase the accuracy of component positioning. Methods A randomized, controlled, prospective study of two groups was performed. In one group, patient-specific custom cutting guides (PSCG) were used for component positioning based on 3D CT-scan planning. In the control group, TKA was performed with a conventional ancillary system. The components' positioning angles were measured on 3D reconstructions. The main evaluation criterion was the percentage of outliers outside of a target zone of +/- 3 degrees for the coronal positioning of the femoral component. Results Eighty patients were included. The percentage of outliers for the femoral component was significantly lower in the 3D-guided group (1 patient) compared to the control group (7 patients p = 0.02). The coronal femoral angle was restored with greater accuracy in the 3D-assisted group (- 0.1 degrees +/- 1.4 degrees) compared to the control group (1.6 degrees +/- 2.5 degrees). Surgery was significantly shorter in the 3D group. The clinical outcomes were better in the 3D group at the two year follow-up with fewer failures and a lower standard deviation in IKS scores. Conclusion The use of a 3D planning and custom guides can improve TKA component positioning by increasing the accuracy of implants alignment and reducing the percentage of outliers. The same benefit was not demonstrated for the global knee alignment and the clinical scores with no indisputable clinical advantage for the PSCG.
引用
收藏
页码:2529 / 2538
页数:10
相关论文
共 50 条
  • [1] Comparison of custom cutting guides based on three-dimensional computerized CT-scan planning and a conventional ancillary system based on two-dimensional planning in total knee arthroplasty: a randomized controlled trial
    Elhadi Sariali
    Charles Kajetanek
    Yves Catonné
    International Orthopaedics, 2019, 43 : 2529 - 2538
  • [2] Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty A Randomized Controlled Trial
    Sariali, Elhadi
    Boukhelifa, Nadia
    Catonne, Yves
    Moussellard, Hugues Pascal
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (02): : 108 - 116
  • [3] Two-Dimensional Versus Three-Dimensional Preoperative Planning in Total Hip Arthroplasty
    Fontalis, Andreas
    Yasen, Adam T.
    Kayani, Babar
    Luo, Tianyi David
    Mancino, Fabio
    Magan, Ahmed
    Plastow, Ricci
    Haddad, Fares S.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S80 - S87
  • [4] Validation of CT-Based Three-Dimensional Preoperative Planning in Comparison with Acetate Templating for Primary Total Hip Arthroplasty
    Chen, Xi
    Wang, Yiou
    Ma, Ruichen
    Peng, Huiming
    Zhu, Shibai
    Li, Shanni
    Li, Songlin
    Dong, Xiying
    Qiu, Guixing
    Qian, Wenwei
    ORTHOPAEDIC SURGERY, 2022, 14 (06) : 1152 - 1160
  • [5] The coronal alignment differs between two-dimensional weight-bearing and three-dimensional nonweight bearing planning in total knee arthroplasty
    Pfluger, Patrick
    Hodel, Sandro
    Zimmermann, Stefan M.
    Knechtle, Svenja
    Vlachopoulos, Lazaros
    Fucentese, Sandro F.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (01)
  • [6] Osteotomies around the knee: preoperative planning using CT-based three-dimensional analysis, patient-specific cutting and reduction guides
    Vlachopoulos, Lazaros
    Fucentese, Sandro F.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2023, 35 (05): : 225 - 238
  • [7] Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements
    Ueyama, Hideki
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Yamamura, Kazumasa
    Nakamura, Suguru
    Takemura, Susumu
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (05) : 1497 - 1503
  • [8] Three-dimensional analysis of accuracy of component positioning in total knee arthroplasty with patient specific and conventional instruments: A randomized controlled trial
    De Vloo, Raf
    Pellikaan, Pim
    Dhollander, Aad
    Vander Sloten, Jos
    KNEE, 2017, 24 (06): : 1469 - 1477
  • [9] Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements
    Hideki Ueyama
    Yukihide Minoda
    Ryo Sugama
    Yoichi Ohta
    Kazumasa Yamamura
    Suguru Nakamura
    Susumu Takemura
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1497 - 1503
  • [10] Comparison of post-operative three-dimensional and two-dimensional evaluation of component position for total knee arthroplasty
    Osamu Tanifuji
    Tomoharu Mochizuki
    Hiroshi Yamagiwa
    Takashi Sato
    Satoshi Watanabe
    Hiroki Hijikata
    Hiroyuki Kawashima
    Knee Surgery & Related Research, 33