Validation of the collapsed cone algorithm for HDR liver brachytherapy against Monte Carlo simulations

被引:2
|
作者
Duque, Anna Sophie [1 ,2 ]
van Wagenberg, Teun [3 ]
Seidensticker, Max [4 ]
Streitparth, Florian [4 ]
Walter, Franziska [1 ]
Parodi, Katia [2 ]
Verhaegen, Frank [3 ]
Ricke, Jens [4 ]
Belka, Claus [1 ,5 ]
Fonseca, Gabriel Paiva [3 ]
Corradini, Stefanie [1 ]
Landry, Guillaume [1 ,2 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Radiat Oncol, Univ Hosp, Marchioninistr 15, D-81377 Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Garching, Germany
[3] Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol, MAASTRO Clin,Med Ctr, Maastricht, Netherlands
[4] Klinikum Univ Munchen, Klin & Poliklin Radiol, Munich, Germany
[5] German Canc Consortium DKTK, Munich, Germany
关键词
Interstitial liver brachytherapy; Radiotherapy; Model-based dose calculation algorithm; Monte Carlo Simulation; AAPM TG-186; Collapsed cone; DOSE CALCULATION ALGORITHM; CT-GUIDED BRACHYTHERAPY; INTERSTITIAL BRACHYTHERAPY; NUCLEAR-DATA; IR-192; METASTASES; DOSIMETRY; TG-43; AAPM; RECOMMENDATIONS;
D O I
10.1016/j.brachy.2021.03.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To validate the collapsed cone (CC) algorithm against Monte Carlo (MC) simulations for model-based dose calculations in high-dose-rate (HDR) liver brachytherapy. METHODS AND MATERIALS: Doses for liver brachytherapy treatment plans of 10 cases were retrospectively recalculated with a model-based approach using Monte Carlo n-Particle Code (MCNP) 6 (Dm,m-MC) and Oncentra Brachy ACE (Dm,m-ACE). Tissue segmentation consisted of assigning uniform compositions and mass densities to predefined Hounsfield Unit (HU) thresholds. Resulting doses were compared according to dose volume histogram parameters typical for clinical routine. These included the percentage liver volume receiving 5 Gy (V5Gy) or 10 Gy (V10Gy), the maximum dose to one cubic centimeter (D1cc) of organs at risk, the clinical target volume (CTV) fractions receiving 150% (V150), 100% (V100), 95% (V95) and 90% (V90) of the prescribed dose and the absolute doses to 95% (D95) and 90% (D90) of the CTV volumes. RESULTS: Doses from Oncentra Brachy ACE agreed well with MC simulations. Differences were seen far from the source, in low-density regions and bone structures. Median percentage deviations were 1.1% for the liver V5Gy and 0.4% for the liver V10Gy, with deviations of largest magnitude amounting to 2.2% and 1.0%, respectively. Organs at risk had median deviations ranging from 0.3% to 1.5% for D1cc, with outliers ranging up to 4.6%. CTV volume parameter deviations ranged between -1.5% and 0.5%, dose parameter deviations ranged mostly between -2% and 1%, with two outliers at -4.0% and -3.4% for a small CTV. (c) 2021 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:936 / 947
页数:12
相关论文
共 50 条
  • [31] Statistics of collapsed lattice animals: Rigorous results and Monte Carlo simulations
    Stratychuk, LM
    Soteros, CE
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 1996, 29 (22): : 7067 - 7087
  • [32] Monte Carlo study of delivered dose as a function of applicator material in HDR brachytherapy
    Danford, C
    Gladstone, D
    MEDICAL PHYSICS, 2005, 32 (06) : 1958 - 1959
  • [33] Monte Carlo study of a bunker used for HDR Ir-192 brachytherapy
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Puchades, V
    Casal, E
    Crispin, V
    Cases, R
    Agramunt, S
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S242 - S242
  • [34] Evaluation of Monte Carlo Simulations Performance for Pediatric Brachytherapy Dosimetry
    Chatzipapas, C.
    Papadimitroulas, P.
    Loudos, G.
    Papanikolaou, N.
    Kagadis, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3472 - 3473
  • [35] Comparing Monte Carlo and Collapsed Cone algorithms for ArcCHECK analysis of complex treatment plans
    Spenkelink, Guus
    Huijskens, Sophie
    Zindler, Jaap
    de Goede, Marc
    van der Star, Jim
    van Egmond, Jaap
    Petoukhova, Anna
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3418 - S3421
  • [36] New algorithm for reverse Monte Carlo simulations
    da, Silva, Fernando Luis B.
    Svensson, Bo
    Akesson, Torbjorn
    Johnsson, Bo
    Journal of Chemical Physics, 1998, 109 (07):
  • [37] Mosaic crystal algorithm for Monte Carlo simulations
    P.A. Seeger
    L.L. Daemen
    Applied Physics A, 2002, 74 : s1458 - s1461
  • [38] Mosaic crystal algorithm for Monte Carlo simulations
    Seeger, PA
    Daemen, LL
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1): : S1458 - S1461
  • [39] A NEW EQUILIBRATION ALGORITHM FOR MONTE CARLO SIMULATIONS
    Yurtsever, E.
    MOLECULAR SIMULATION, 1989, 2 (03) : 189 - 199
  • [40] Worm algorithm in quantum Monte Carlo simulations
    Prokof'ev, N.V.
    Svistunov, B.V.
    Tupitsyn, I.S.
    Physics Letters, Section A: General, Atomic and Solid State Physics, 1998, 238 (4-5): : 253 - 257