Validation of the collapsed cone algorithm for HDR liver brachytherapy against Monte Carlo simulations

被引:2
|
作者
Duque, Anna Sophie [1 ,2 ]
van Wagenberg, Teun [3 ]
Seidensticker, Max [4 ]
Streitparth, Florian [4 ]
Walter, Franziska [1 ]
Parodi, Katia [2 ]
Verhaegen, Frank [3 ]
Ricke, Jens [4 ]
Belka, Claus [1 ,5 ]
Fonseca, Gabriel Paiva [3 ]
Corradini, Stefanie [1 ]
Landry, Guillaume [1 ,2 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Radiat Oncol, Univ Hosp, Marchioninistr 15, D-81377 Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Garching, Germany
[3] Maastricht Univ, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol, MAASTRO Clin,Med Ctr, Maastricht, Netherlands
[4] Klinikum Univ Munchen, Klin & Poliklin Radiol, Munich, Germany
[5] German Canc Consortium DKTK, Munich, Germany
关键词
Interstitial liver brachytherapy; Radiotherapy; Model-based dose calculation algorithm; Monte Carlo Simulation; AAPM TG-186; Collapsed cone; DOSE CALCULATION ALGORITHM; CT-GUIDED BRACHYTHERAPY; INTERSTITIAL BRACHYTHERAPY; NUCLEAR-DATA; IR-192; METASTASES; DOSIMETRY; TG-43; AAPM; RECOMMENDATIONS;
D O I
10.1016/j.brachy.2021.03.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To validate the collapsed cone (CC) algorithm against Monte Carlo (MC) simulations for model-based dose calculations in high-dose-rate (HDR) liver brachytherapy. METHODS AND MATERIALS: Doses for liver brachytherapy treatment plans of 10 cases were retrospectively recalculated with a model-based approach using Monte Carlo n-Particle Code (MCNP) 6 (Dm,m-MC) and Oncentra Brachy ACE (Dm,m-ACE). Tissue segmentation consisted of assigning uniform compositions and mass densities to predefined Hounsfield Unit (HU) thresholds. Resulting doses were compared according to dose volume histogram parameters typical for clinical routine. These included the percentage liver volume receiving 5 Gy (V5Gy) or 10 Gy (V10Gy), the maximum dose to one cubic centimeter (D1cc) of organs at risk, the clinical target volume (CTV) fractions receiving 150% (V150), 100% (V100), 95% (V95) and 90% (V90) of the prescribed dose and the absolute doses to 95% (D95) and 90% (D90) of the CTV volumes. RESULTS: Doses from Oncentra Brachy ACE agreed well with MC simulations. Differences were seen far from the source, in low-density regions and bone structures. Median percentage deviations were 1.1% for the liver V5Gy and 0.4% for the liver V10Gy, with deviations of largest magnitude amounting to 2.2% and 1.0%, respectively. Organs at risk had median deviations ranging from 0.3% to 1.5% for D1cc, with outliers ranging up to 4.6%. CTV volume parameter deviations ranged between -1.5% and 0.5%, dose parameter deviations ranged mostly between -2% and 1%, with two outliers at -4.0% and -3.4% for a small CTV. (c) 2021 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:936 / 947
页数:12
相关论文
共 50 条
  • [21] COMPARISON OF HDR BRACHYTHERAPY SOURCES IN MONTE CARLO INVERSE PLANNING
    D'Amours, M.
    Liu, D.
    Lessard, E.
    Pouliot, J.
    Verhaegen, F.
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 : S15 - S15
  • [22] Monte Carlo Simulations on GPU for Brachytherapy Applications
    Lemarechal, Yannick
    Bert, Julien
    Boussion, Nicolas
    Le Fur, Emmanuelle
    Visvikis, Dimitris
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [23] MONTE CARLO DOSE CALCULATION VS. ENHANCED COLLAPSED CONE ALGORITHM FOR IMRT TREATMENT PLANNING
    Fotina, I.
    Kroupa, B.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S58 - S58
  • [24] The Comparison of Collapsed Cone and Monte Carlo Tangential Breast EBRT Plans
    Goss, M.
    Trombetta, M.
    Eisen, V.
    Demartino, V.
    MEDICAL PHYSICS, 2022, 49 (06) : E929 - E930
  • [25] The comparison of collapsed cone and Monte Carlo algorithms in tangential breast planning
    Goss, Matthew
    Champ, Colin
    Trombetta, Mark
    Shamsesfandabadi, Parisa
    DeMartino, Valerie
    Wegner, Rodney
    Beriwal, Sushil
    Eisen, Veronica
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [26] Clinical Comparison of Dose Calculation Using the Enhanced Collapsed Cone Algorithm vs. a New Monte Carlo Algorithm
    Fotina, Irina
    Kragl, Gabriele
    Kroupa, Bernhard
    Trausmuth, Robert
    Georg, Dietmar
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (07) : 433 - 441
  • [27] Monte Carlo dosimetry of 60Co HDR brachytherapy sources
    Papagiannis, P
    Angelopoulos, A
    Pantelis, E
    Sakelliou, L
    Karaiskos, P
    Shimizu, Y
    MEDICAL PHYSICS, 2003, 30 (04) : 712 - 721
  • [28] Monte Carlo simulation of HDR Brachytherapy dosimetric parameters in different mediums
    Shukor, Nor Shazleen Ab
    Musarudin, Marianie
    Abdullah, Reduan
    Aziz, Mohd Zahri Abd
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [29] Validation of HDR brachytherapy doses in the treatment of keloid scars using the egs_brachy Monte Carlo application
    Saikkonen, Aleksi
    Ojala, Jarkko
    Sipila, Petri
    Boman, Eeva
    Keyrilaeinen, Jani
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (08):
  • [30] The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy
    Carlsson, ÅK
    Ahnesjö, A
    MEDICAL PHYSICS, 2000, 27 (10) : 2320 - 2332