Comparison of the Effect of Laryngeal Mask Airway Versus Endotracheal Tube on Airway Management in Pediatric Patients with Tonsillar Hypertrophy

被引:4
|
作者
Liu, Xiang [1 ]
Cao, Hongyan [1 ]
Tan, Xiaona [2 ]
Qiao, Li [1 ]
Zhang, Qi [1 ]
Shi, Lei [1 ]
机构
[1] Hebei Med Univ, Affiliated Childrens Hosp Hebei Prov, Dept Operating Room & Anesthesiol, Shijiazhuang, Hebei, Peoples R China
[2] Hebei Med Univ, Affiliated Childrens Hosp Hebei Prov, Dept Neurol Rehabil, Shijiazhuang, Hebei, Peoples R China
关键词
supraglottic airway; children; surgical procedures; laparoscopic; anesthesia; general; tonsillar hypertrophy; PRESSURE; VENTILATION; INFANTS;
D O I
10.1016/j.jopan.2020.06.020
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Purpose: The laryngeal mask airway (LMA) has become an important choice in both routine and difficult airway management. We aimed to evaluate the safety and effectiveness of LMA use in pediatric patients with tonsillar hypertrophy. Design: This study was a randomized controlled trial. Methods: The study included 100 pediatric patients who had first or second degree tonsillar hypertrophy. Pediatric patients undergoing elective laparoscopic inguinal hernia repair were randomly divided into two groups (n = 50): LMA group and the endotracheal tube (ETT) group. The primary outcomes were ventilation leak volume, peak airway pressure, and partial pressure of end-tidal carbon dioxide (PETCO2). Data for primary outcomes were collected before and 5-, 15-, and 25-minute after opening pneumoperitoneum, and on closing the pneumoperitoneum. Complications such as laryngospasm, bronchospasm, desaturation, severe coughing, blood on the device after removal, and sore throat were recorded. Findings: A total of 100 pediatric patients were assessed and 97 eligible patients were randomly assigned to receive an LMA (n = 49) or an ETT (n = 48). There was no statistically significant difference in ventilation leak volume and PETCO2 between the LMA and ETT groups (P > .05). Compared with T1-4, peak airway pressure was significantly lower in T0 (LMA group 12.6 ? 0.9, 95% confidence interval 12.2 to 13.0; ETT group 12.8 ? 1.2, 95% confidence interval 12.2 to 13.3; P < .05). The incidences of laryngospasm 11 (22.9%), desaturation 18 (37.5%), and severe coughing 13 (27%) were higher in the ETT group (11 [22.9%] vs 3 [6.1%], 18 [37.5%] vs 6 [12.2%], 13 [27%] vs 3 [6.1%]; P < .05). Conclusions: The application of LMA has a lower incidence of complications. LMA as an airway device is effective and perhaps superior in appropriate patients. @& nbsp;2020 American Society of PeriAnesthesia Nurses. Published by Elsevier, Inc. All rights reserved.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [41] An Ultrasound Evaluation of Laryngeal Mask Airway Position in Pediatric Patients: An Observational Study
    Kim, Jeongmin
    Kim, Ji Young
    Kim, Won Oak
    Kil, Hae Keum
    ANESTHESIA AND ANALGESIA, 2015, 120 (02) : 427 - 432
  • [42] Gastro-oesophageal reflux during anaesthesia in the kitten: comparison between use of a laryngeal mask airway or an endotracheal tube
    Sideri, Aikaterini I.
    Galatos, Apostolos D.
    Kazakos, George M.
    Gouletsou, Pagona G.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2009, 36 (06) : 547 - 554
  • [43] Interdisciplinary consensus statement on alternative airway management with supraglottic airway devices in pediatric emergency medicine. Laryngeal mask is state of the art
    Keil, J.
    Jung, P.
    Schiele, A.
    Urban, B.
    Parsch, A.
    Matsche, B.
    Eich, C.
    Becke, K.
    Landsleitner, B.
    Russo, S. G.
    Bernhard, M.
    Nicolai, T.
    Hoffmann, F.
    ANAESTHESIST, 2016, 65 (01): : 57 - 66
  • [44] A Study of the Use of Laryngeal Mask Airway (LMA) in Children and its Comparison with Endotracheal Intubation
    Jamil, Shahin N.
    Alam, Mehtab
    Usmani, Hammad
    Khan, M. M.
    INDIAN JOURNAL OF ANAESTHESIA, 2009, 53 (02) : 174 - 178
  • [45] Resistive load of laryngeal mask airway and proseal laryngeal mask airway in mechanically ventilated patients
    Natalini, G
    Rosano, A
    Lanza, G
    Martinelli, E
    Pletti, C
    Bernardini, A
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2003, 47 (06) : 761 - 764
  • [46] Comparison of ProSeal™ laryngeal mask airway (PLMA) with cuffed and uncuffed endotracheal tubes in infants
    Ozden, Eyyup Sabri
    Meco, Basak Ceyda
    Alanoglu, Zekeriyya
    Alkis, Neslihan
    BOSNIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2016, 16 (04) : 286 - 291
  • [47] A comparison of the Supreme™ laryngeal mask airway with the Proseal™ laryngeal mask airway in anesthetized paralyzed adult patients: a randomized crossover study
    Tham, Huae Min
    Tan, Su Meng
    Woon, Kwee Lian
    Zhao, Yu Dong
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (07): : 672 - 678
  • [48] COMPLICATIONS ASSOCIATED WITH REMOVAL OF THE LARYNGEAL MASK AIRWAY - A COMPARISON OF REMOVAL IN DEEPLY ANESTHETIZED VERSUS AWAKE PATIENTS
    GATAURE, PS
    LATTO, IP
    RUST, S
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (12): : 1113 - 1116
  • [49] A comparison of laryngeal mask airway-supreme and endotracheal tube use with respect to airway protection in patients undergoing septoplasty: a randomized, single-blind, controlled clinical trial
    Karaaslan, Erol
    Akbas, Sedat
    Ozkan, Ahmet Selim
    Colak, Cemil
    Begec, Zekine
    BMC ANESTHESIOLOGY, 2021, 21 (01)
  • [50] A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: performance and fiberoptic findings
    Fukuhara, Aya
    Okutani, Ryu
    Oda, Yutaka
    JOURNAL OF ANESTHESIA, 2013, 27 (01) : 1 - 6