Performance analysis of solar parabolic trough collectors driven combined supercritical CO2 and organic Rankine cycle

被引:56
作者
Singh, Harwinder [1 ]
Mishra, R. S. [1 ]
机构
[1] Delhi Technol Univ, Automobile Engn, Dept Mech Prod & Ind, Bawana Rd, New Delhi 110042, India
来源
ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH | 2018年 / 21卷 / 03期
关键词
Supercritical CO(2)cycle; Organic Rankine cycle; Exergetic performance; SPTCs; Organic fluids; PRELIMINARY DESIGN; EXERGY ANALYSIS; WORKING FLUIDS; POWER-PLANT; GENERATION; OPTIMIZATION; STEAM; SEAWATER; ORCS;
D O I
10.1016/j.jestch.2018.03.015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, attempts have been made on the detailed energy and exergy analysis of solar parabolic trough collectors (SPTCs) driven combined power plant. The combination of supercritical CO2 (SCO2) cycle and organic Rankine cycle (ORC) integrated with SPTCs has been used to produce power, in which SCO2 cycle and ORC are arranged as a topping and bottoming cycle. Five organic working fluids like R134a, R1234yf, R407c, R1234ze, and R245fa were selected for a low temperature bottoming ORC. Five key exergetic parameters such as exergetic efficiency, exergy destruction rate, fuel depletion ratio, irreversibility ratio, and improvement potential were also examined. It was revealed that exergetic and thermal efficiency of all the combined cycles enhances as the direct normal irradiance increases from 0.5 kW/m(2) to 0.95 kW/m(2). As can be seen, R407c combined cycle has the maximum exergetic as well as thermal efficiency which is around 78.07% at 0.95 kW/m(2) and 43.49% at 0.95 kW/m(2), respectively. Alternatively, the R134a and R245fa combined cycle yields less promising results with the marginal difference in their performance. As inferred from the study that SCO2 turbine and evaporator has a certain amount of exergy destruction which is around 9.72% and 8.54% of the inlet exergy, and almost 38.10% of the total exergy destruction in case of R407c combined cycle. Moreover, the maximum amount of exergy destructed by the solar collector field which is more than 25% of the solar inlet exergy and around 54% of the total destructed exergy. Finally, this study concludes that R407c combined cycle has a minimum fuel depletion ratio of 0.2583 for a solar collector and possess the highest power output of 3740 kW. (C) 2018 Karabuk University. Publishing services by Elsevier B. V.
引用
收藏
页码:451 / 464
页数:14
相关论文
共 56 条
[1]  
Aghahosseini S, 2011, P GLOB C GLOB WARM L
[2]   REVIEW OF SUPERCRITICAL CO2 POWER CYCLE TECHNOLOGY AND CURRENT STATUS OF RESEARCH AND DEVELOPMENT [J].
Ahn, Yoonhan ;
Bae, Seong Jun ;
Kim, Minseok ;
Cho, Seong Kuk ;
Baik, Seungjoon ;
Lee, Jeong Ik ;
Cha, Jae Eun .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2015, 47 (06) :647-661
[3]   Exergy analysis of parabolic trough solar collectors integrated with combined steam and organic Rankine cycles [J].
Al-Sulaiman, Fahad A. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 77 :441-449
[4]   Performance assessment of a novel system using parabolic trough solar collectors for combined cooling, heating, and power production [J].
Al-Sulaiman, Fahad A. ;
Hamdullahpur, Feridun ;
Dincer, Ibrahim .
RENEWABLE ENERGY, 2012, 48 :161-172
[5]   Exergy modeling of a new solar driven trigeneration system [J].
Al-Sulaiman, Fahad A. ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
SOLAR ENERGY, 2011, 85 (09) :2228-2243
[6]  
[Anonymous], 1994, SANDIA941884 SAND NA
[7]  
[Anonymous], 2012, KTH IND ENG MANAG
[8]   Analysis of Advanced Supercritical Carbon Dioxide Power Cycles With a Bottoming Cycle for Concentrating Solar Power Applications [J].
Besarati, Saeb M. ;
Goswami, D. Yogi .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (01)
[9]  
Blanco M.J., 2017, WOODHEAD PUBLISHING
[10]   MAXIMUM PERFORMANCE OF SOLAR HEAT ENGINES [J].
BOEHM, RF .
APPLIED ENERGY, 1986, 23 (04) :281-296