The dose accumulation and the impact of deformable image registration on dose reporting parameters in a moving patient undergoing proton radiotherapy

被引:1
|
作者
Razdevsek, Gasper [1 ]
Simoncic, Urban [1 ,2 ]
Snoj, Luka [1 ,2 ]
Studen, Andrej [1 ,2 ]
机构
[1] Univ Ljubljana, Fac Math & Phys, Jadranska 19, SI-1000 Ljubljana, Slovenia
[2] Jozef Stefan Inst, Ljubljana, Slovenia
关键词
proton therapy; adaptive therapy; MCNP6; dose distribution measurement; Monte-Carlo; dose homogeneity; image registration; RADIATION-THERAPY; CANCER; MOTION; DELIVERY;
D O I
10.2478/raon-2022-0016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction Potential changes in patient anatomy during proton radiotherapy may lead to a deviation of the delivered dose. A dose estimate can be computed through a deformable image registration (DIR) driven dose accumulation. The present study evaluates the accumulated dose uncertainties in a patient subject to an inadvertent breathing associated motion. Materials and methods A virtual lung tumour was inserted into a pair of single participant landmark annotated computed tomography images depicting opposite breathing phases, with the deep inspiration breath-hold the planning reference and the exhale the off-reference geometry. A novel Monte Carlo N-Particle, Version 6 (MCNP6) dose engine was developed, validated and used in treatment plan optimization. Three DIR methods were compared and used to transfer the exhale simulated dose to the reference geometry. Dose conformity and homogeneity measures from International Committee on Radioactivity Units and Measurements (ICRU) reports 78 and 83 were evaluated on simulated dose distributions registered with different DIR algorithms. Results The MCNP6 dose engine handled patient-like geometries in reasonable dose calculation times. All registration methods were able to align image associated landmarks to distances, comparable to voxel sizes. A moderate deterioration of ICRU measures was encountered in comparing doses in on and off-reference anatomy. There were statistically significant DIR driven differences in ICRU measures, particularly a 10% difference in the relative D-98% for planning tumour volume and in the 3 mm/3% gamma passing rate. Conclusions T he dose accumulation over two anatomies resulted in a DIR driven uncertainty, important in reporting the associated ICRU measures for quality assurance.
引用
收藏
页码:248 / 258
页数:11
相关论文
共 50 条
  • [41] Dose accumulation during vaginal cuff brachytherapy based on rigid/deformable registration vs. single plan addition
    Sabater, Sebastia
    Andres, Ignacio
    Sevillano, Marimar
    Berenguer, Roberto
    Machin-Hamalainen, Santiago
    Arenas, Meritxell
    BRACHYTHERAPY, 2014, 13 (04) : 343 - 351
  • [42] Dose-guided patient positioning in proton radiotherapy using multicriteria-optimization
    Kurz, Christopher
    Suess, Philipp
    Arnsmeyer, Carolin
    Haehnle, Jonas
    Teichert, Katrin
    Landry, Guillaume
    Hofmaier, Jan
    Exner, Florian
    Hille, Lucas
    Kamp, Florian
    Thieke, Christian
    Ganswindt, Ute
    Valentini, Chiara
    Hoelscher, Tobias
    Troost, Esther
    Krause, Mechthild
    Belka, Claus
    Kuefer, Karl-Heinz
    Parodi, Katia
    Richter, Christian
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (03): : 216 - 228
  • [43] Simple DVH parameter addition as compared to deformable registration for bladder dose accumulation in cervix cancer brachytherapy
    Andersen, Else Stougard
    Noe, Karsten Ostergaard
    Sorensen, Thomas Sangild
    Nielsen, Soren Kynde
    Fokdal, Lars
    Paludan, Merete
    Lindegaard, Jacob Christian
    Tanderup, Kari
    RADIOTHERAPY AND ONCOLOGY, 2013, 107 (01) : 52 - 57
  • [44] The influence of MRI scan position on image registration accuracy, target delineation and calculated dose in prostatic radiotherapy
    Hanvey, S.
    Sadozye, A. H.
    McJury, M.
    Glegg, M.
    Foster, J.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1020) : E1256 - E1262
  • [45] A multi-institutional comparison of retrospective deformable dose accumulation for online adaptive magnetic resonance-guided radiotherapy
    Murr, Martina
    Bernchou, Uffe
    Bubula-Rehm, Edyta
    Ruschin, Mark
    Sadeghi, Parisa
    Voet, Peter
    Winter, Jeff D.
    Yang, Jinzhong
    Younus, Eyesha
    Zachiu, Cornel
    Zhao, Yao
    Zhong, Hualiang
    Thorwarth, Daniela
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [46] On Voxel-by-voxel Accumulated Dose for Prostate Radiation Therapy using Deformable Image Registration
    Yu, Jialu
    Hardcastle, Nicholas
    Jeong, Kyoungkeun
    Bender, Edward T.
    Ritter, Mark A.
    Tome, Wolfgang A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (01) : 37 - 47
  • [47] Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping
    Salguero, Francisco J.
    Saleh-Sayah, Nahla K.
    Yan, Chenyu
    Siebers, Jeffrey V.
    MEDICAL PHYSICS, 2011, 38 (01) : 343 - 353
  • [48] Contour-guided deep learning based deformable image registration for dose monitoring during CBCT-guided radiotherapy of prostate cancer
    Hemon, Cedric
    Rigaud, Bastien
    Barateau, Anais
    Tilquin, Florian
    Noblet, Vincent
    Sarrut, David
    Meyer, Philippe
    Bert, Julien
    De Crevoisier, Renaud
    Simon, Antoine
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (08):
  • [49] Impact of Anatomical Position Errors on Dose Distribution in Head and Neck Radiotherapy and Robust Image Registration Against Anatomical Changes
    Hirotaki, Kouta
    Tomizawa, Kento
    Moriya, Shunsuke
    Ito, Masashi
    Sakae, Takeji
    ANTICANCER RESEARCH, 2023, 43 (04) : 1827 - 1834
  • [50] Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for "dose of the day" calculations
    Veiga, Catarina
    McClelland, Jamie
    Moinuddin, Syed
    Lourenco, Ana
    Ricketts, Kate
    Annkah, James
    Modat, Marc
    Ourselin, Sebastien
    D'Souza, Derek
    Royle, Gary
    MEDICAL PHYSICS, 2014, 41 (03)