The dose accumulation and the impact of deformable image registration on dose reporting parameters in a moving patient undergoing proton radiotherapy

被引:1
|
作者
Razdevsek, Gasper [1 ]
Simoncic, Urban [1 ,2 ]
Snoj, Luka [1 ,2 ]
Studen, Andrej [1 ,2 ]
机构
[1] Univ Ljubljana, Fac Math & Phys, Jadranska 19, SI-1000 Ljubljana, Slovenia
[2] Jozef Stefan Inst, Ljubljana, Slovenia
关键词
proton therapy; adaptive therapy; MCNP6; dose distribution measurement; Monte-Carlo; dose homogeneity; image registration; RADIATION-THERAPY; CANCER; MOTION; DELIVERY;
D O I
10.2478/raon-2022-0016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction Potential changes in patient anatomy during proton radiotherapy may lead to a deviation of the delivered dose. A dose estimate can be computed through a deformable image registration (DIR) driven dose accumulation. The present study evaluates the accumulated dose uncertainties in a patient subject to an inadvertent breathing associated motion. Materials and methods A virtual lung tumour was inserted into a pair of single participant landmark annotated computed tomography images depicting opposite breathing phases, with the deep inspiration breath-hold the planning reference and the exhale the off-reference geometry. A novel Monte Carlo N-Particle, Version 6 (MCNP6) dose engine was developed, validated and used in treatment plan optimization. Three DIR methods were compared and used to transfer the exhale simulated dose to the reference geometry. Dose conformity and homogeneity measures from International Committee on Radioactivity Units and Measurements (ICRU) reports 78 and 83 were evaluated on simulated dose distributions registered with different DIR algorithms. Results The MCNP6 dose engine handled patient-like geometries in reasonable dose calculation times. All registration methods were able to align image associated landmarks to distances, comparable to voxel sizes. A moderate deterioration of ICRU measures was encountered in comparing doses in on and off-reference anatomy. There were statistically significant DIR driven differences in ICRU measures, particularly a 10% difference in the relative D-98% for planning tumour volume and in the 3 mm/3% gamma passing rate. Conclusions T he dose accumulation over two anatomies resulted in a DIR driven uncertainty, important in reporting the associated ICRU measures for quality assurance.
引用
收藏
页码:248 / 258
页数:11
相关论文
共 50 条
  • [11] Deformable dose accumulation is required for adaptive radiotherapy practice
    Zhong, Hualiang
    Pursley, Jennifer M.
    Rong, Yi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [12] Deformable Image Registration Based Delivered Dose Estimation for Head and Neck Radiotherapy
    Kumarasiri, A.
    Liu, C.
    Chetvertkov, M.
    Gordon, J.
    Siddiqui, F.
    Chetty, I.
    Kim, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 191 - 192
  • [13] Image registration, contour propagation and dose accumulation of external beam and brachytherapy in gynecological radiotherapy
    Swamidas, Jamema
    Kirisits, Christian
    De Brabandere, Marisol
    Hellebust, Taran Paulsen
    Siebert, Frank-Andre
    Tanderup, Kari
    RADIOTHERAPY AND ONCOLOGY, 2020, 143 : 1 - 11
  • [14] Deep learning based uncertainty prediction of deformable image registration for contour propagation and dose accumulation in online adaptive radiotherapy
    Smolders, A.
    Lomax, A.
    Weber, D. C.
    Albertini, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (24)
  • [15] Impact of deformable image registration on dose accumulation applied electrocardiograph-gated 4DCT in the heart and left ventricular myocardium during esophageal cancer radiotherapy
    Tong, Ying
    Yin, Yong
    Cheng, Pinjing
    Gong, Guanzhong
    RADIATION ONCOLOGY, 2018, 13
  • [16] Use of a DVH overlay technique for quality assurance of deformable image registration-based dose accumulation
    Kainz, Kristofer
    Garcia Alvarez, Juan
    Zhong, Hualiang
    Lim, Sara
    Ahunbay, Ergun
    Tai, An
    Erickson, Beth
    Lawton, Colleen
    Li, X. Allen
    MEDICAL PHYSICS, 2022, 49 (01) : 611 - 623
  • [17] Evaluating the accumulated dose distribution of organs at risk in combined radiotherapy for cervical carcinoma based on deformable image registration
    Zhao, Tiandi
    Chen, Yi
    Qiu, Bin
    Zhang, Jiashuang
    Liu, Hao
    Zhang, Xile
    Zhang, Ruilin
    Jiang, Ping
    Wang, Junjie
    BRACHYTHERAPY, 2023, 22 (02) : 174 - 180
  • [18] Four-dimensional dose evaluation using deformable image registration in radiotherapy for liver cancer
    Jung, Sang Hoon
    Yoon, Sang Min
    Park, Sung Ho
    Cho, Byungchul
    Park, Jae Won
    Jung, Jinhong
    Park, Jin-hong
    Kim, Jong Hoon
    Ahn, Seung Do
    MEDICAL PHYSICS, 2013, 40 (01)
  • [19] Dose accumulation with deformable image registration method using helical tomotherapy images for prostate cancer
    Thongsuk, Warit
    Chitapanarux, Imjai
    Wanwilairat, Somsak
    Nobnop, Wannapha
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (01) : 25 - 29
  • [20] Accumulation of the delivered dose based on cone-beam CT and deformable image registration for non-small cell lung cancer treated with hypofractionated radiotherapy
    Wang, Bin
    Wang, Da Quan
    Lin, Mao Sheng
    Lu, Shi Pei
    Zhang, Jun
    Chen, Li
    Li, Qi Wen
    Cheng, Zhang Kai
    Liu, Fang Jie
    Guo, Jin Yu
    Liu, Hui
    Qiu, Bo
    BMC CANCER, 2020, 20 (01)