Development of glucose oxidase-chitosan immobilized paper biosensor using screen-printed electrode for amperometric detection of Cr(VI) in water

被引:18
作者
Dabhade, Ajinkya [1 ]
Jayaraman, Sivaraman [2 ]
Paramasivan, Balasubramanian [1 ]
机构
[1] Natl Inst Technol Rourkela, Agr & Environm Biotechnol Grp, Dept Biotechnol & Med Engn, Rourkela 769008, Odisha, India
[2] Natl Inst Technol Rourkela, Dept Biotechnol & Med Engn, Med Elect & Instrumentat Grp, Rourkela 769008, Odisha, India
关键词
Paper biosensor; Screen-printed carbon electrode; Glucose Oxidase; Inhibition; Chronoamperometry; Hexavalent Chromium; ELECTROCHEMICAL DETECTION; ENZYME IMMOBILIZATION; ANALYTICAL DEVICES; CROSS-LINKING; INHIBITION; CHROMIUM; GLUTARALDEHYDE; FABRICATION;
D O I
10.1007/s13205-021-02736-5
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Hexavalent chromium is a toxic heavy metal getting discharged into the environment and water bodies through various industrial processes. Conventional analysis methods call for expensive equipment and complicated sample pretreatment that made unsuitable for onsite detection. Paper is used as an enzyme immobilization platform because of its property to wick the liquid by capillary action; lightweight, cheap and can be easily patterned or cut according to the requirements for developing biosensor. In this study, enzyme immobilization of glucose oxidase (GOx) on filter paper were examined using three polysaccharides such as chitosan, sodium alginate and dextran for entrapment efficiency, activity and stability of the immobilized enzyme. Among the three, chitosan proved efficient for enzyme entrapment with about 90% efficiency at 0.3% (w/v) chitosan. The stability was checked after 1 week at 4 degrees C and room temperature, where the chitosan entrapped enzyme retained nearly 97% stability at 4 degrees C. Enzyme inhibition study of GOx and Cr(VI) was carried out using chronoamperometry shown uncompetitive type of inhibition. A paper-based electrochemical biosensor strip was developed by immobilizing GOx enzyme on filter paper using chitosan as an entrapping agent and associating it with a screen-printed carbon electrode for amperometric measurements. The linear range of detection was obtained as 0.05-1 ppm with the limit of detection as 0.05 ppm for Cr(VI), which is the standard permissible limit in potable water. The relative standard deviation (5.6%) indicates good reproducibility of the fabricated biosensor.
引用
收藏
页数:11
相关论文
共 45 条
  • [31] Novel Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Azide Covalently Immobilized on Ethynyl-Modified Screen-Printed Carbon Electrode via Click Chemistry
    Hayat, Akhtar
    Marty, Jean-Louis
    Radi, Abd-Elgawad
    ELECTROANALYSIS, 2012, 24 (06) : 1446 - 1452
  • [32] Development of a molecularly imprinted electrochemical sensor for erlotinib detection using a modified screen-printed carbon electrode
    Ahmed, Saif Ali
    Roushani, Mahmoud
    Karazan, Zahra Mirzaei
    MICROCHIMICA ACTA, 2025, 192 (03)
  • [33] Electrochemical detection of blood alcohol concentration using a disposable biosensor based on screen-printed electrode modified with Nafion and gold nanoparticles
    Luo, Peng
    Xie, Guoming
    Liu, Yi
    Xu, Huajian
    Deng, Shixiong
    Song, Fangzhou
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (11) : 1641 - 1647
  • [34] An electrochemical biosensor based on multi-wall carbon nanotube-modified screen-printed electrode immobilized by uricase for the detection of salivary uric acid
    Shi, Weishan
    Li, Jing
    Wu, Jie
    Wei, Qianying
    Chen, Cuili
    Bao, Ning
    Yu, Chunmei
    Gu, Haiying
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (26) : 7275 - 7283
  • [35] A highly sensitive and selective electrochemical sensor for determination of Cr(VI) in the presence of Cr(III) using modified multi-walled carbon nanotubes/quercetin screen-printed electrode
    Sadeghi, Susan
    Garmroodi, Aziz
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (08): : 4972 - 4977
  • [36] High-performance amperometric biosensor for flow injection analysis consisting of a replaceable lactate oxidase-based mini-reactor and a silver amalgam screen-printed electrode
    Tvorynska, Sofiia
    Barek, Jiri
    Josypcuk, Bohdan
    ELECTROCHIMICA ACTA, 2023, 445
  • [37] Development of a Disposable, Amperometric Glycerol Biosensor Based on a Screen-Printed Carbon Electrode, Modified with the Electrocatalyst Meldolas Blue, Coated with Glycerol Dehydrogenase and NAD+: Application to the Analysis of Wine Quality
    Ekonomou, Sotirios I.
    Crew, Adrian
    Doran, Olena
    Hart, John P.
    APPLIED SCIENCES-BASEL, 2024, 14 (14):
  • [38] A Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes Modified with Silver Nanowires/HPMC/Chitosan/Urease for the Detection of Mercury (II) in Water
    Saenchoopa, Apichart
    Klangphukhiew, Supannika
    Somsub, Rachata
    Talodthaisong, Chanon
    Patramanon, Rina
    Daduang, Jureerut
    Daduang, Sakda
    Kulchat, Sirinan
    BIOSENSORS-BASEL, 2021, 11 (10):
  • [39] Identification of Influential Factors in the Development of Modified Screen-printed Carbon Electrode in the DNA-based Electrochemical Biosensor Using the Design of Experiment
    Muflihah
    Hardianto, Ari
    Irkham
    Zakiyyah, Salma Nur
    Kusumaningtyas, Pintaka
    Prabowo, Sulistyo
    Hartati, Yeni Wahyuni
    SENSORS AND MATERIALS, 2023, 35 (12) : 4235 - 4250
  • [40] Development of a disposable amperometric NH4+ biosensor based on a chemically modified screen-printed carbon electrode coated with glutamate dehydrogenase, 2-oxoglutarate, and NADH
    Hart, JP
    Abass, AK
    Cowell, DC
    Chappell, A
    ELECTROANALYSIS, 1999, 11 (06) : 406 - 411