摘要
Hexavalent chromium is a toxic heavy metal getting discharged into the environment and water bodies through various industrial processes. Conventional analysis methods call for expensive equipment and complicated sample pretreatment that made unsuitable for onsite detection. Paper is used as an enzyme immobilization platform because of its property to wick the liquid by capillary action; lightweight, cheap and can be easily patterned or cut according to the requirements for developing biosensor. In this study, enzyme immobilization of glucose oxidase (GOx) on filter paper were examined using three polysaccharides such as chitosan, sodium alginate and dextran for entrapment efficiency, activity and stability of the immobilized enzyme. Among the three, chitosan proved efficient for enzyme entrapment with about 90% efficiency at 0.3% (w/v) chitosan. The stability was checked after 1 week at 4 degrees C and room temperature, where the chitosan entrapped enzyme retained nearly 97% stability at 4 degrees C. Enzyme inhibition study of GOx and Cr(VI) was carried out using chronoamperometry shown uncompetitive type of inhibition. A paper-based electrochemical biosensor strip was developed by immobilizing GOx enzyme on filter paper using chitosan as an entrapping agent and associating it with a screen-printed carbon electrode for amperometric measurements. The linear range of detection was obtained as 0.05-1 ppm with the limit of detection as 0.05 ppm for Cr(VI), which is the standard permissible limit in potable water. The relative standard deviation (5.6%) indicates good reproducibility of the fabricated biosensor.
引用
收藏
页数:11
相关论文
共 45 条
  • [21] Development of a high analytical performance amperometric glucose biosensor based on glucose oxidase immobilized in a composite matrix: layered double hydroxides/chitosan
    Qiaofang Shi
    En Han
    Dan Shan
    Wenjuan Yao
    Huaiguo Xue
    Bioprocess and Biosystems Engineering, 2008, 31 : 519 - 526
  • [22] Development of a high analytical performance amperometric glucose biosensor based on glucose oxidase immobilized in a composite matrix: layered double hydroxides/chitosan
    Shi, Qiaofang
    Han, En
    Shan, Dan
    Yao, Wenjuan
    Xue, Huaiguo
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2008, 31 (06) : 519 - 526
  • [23] Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer
    Boujtita, M
    Hart, JP
    Pittson, R
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) : 257 - 263
  • [24] Sensitive Acetylcholinesterase Biosensor Based on Screen-Printed Carbon Electrode Modified with Cerium Oxide-Chitosan/Mesoporous Carbon-Chitosan for Organophosphorus Pesticide Residue Detection
    Fu, Jiayun
    Zhang, Qianqian
    Shi, Zhaoqiang
    Guo, Yemin
    Li, Falan
    Zhang, Yanyan
    Sun, Xia
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09): : 9231 - 9241
  • [25] A paper disk equipped with graphene/polyaniline/Au nanoparticles/glucose oxidase biocomposite modified screen-printed electrode: Toward whole blood glucose determination
    Kong, Fen-Ying
    Gu, Sai-Xi
    Li, Wei-Wei
    Chen, Ting-Ting
    Xu, Qin
    Wang, Wei
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 77 - 82
  • [26] Glucose determination in blood samples using flow injection analysis and an amperometric biosensor based on glucose oxidase immobilized on hexacyanoferrate modified nickel electrode
    Milardovic, S
    Kruhak, I
    Ivekovic, D
    Rumenjak, V
    Tkalcec, M
    Grabaric, BS
    ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) : 91 - 96
  • [27] Direct electrochemistry of glucose oxidase and sensing glucose using a screen-printed carbon electrode modified with graphite nanosheets and zinc oxide nanoparticles
    Chelladurai Karuppiah
    Selvakumar Palanisamy
    Shen-Ming Chen
    Vediyappan Veeramani
    Prakash Periakaruppan
    Microchimica Acta, 2014, 181 : 1843 - 1850
  • [28] Direct electrochemistry of glucose oxidase and sensing glucose using a screen-printed carbon electrode modified with graphite nanosheets and zinc oxide nanoparticles
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    MICROCHIMICA ACTA, 2014, 181 (15-16) : 1843 - 1850
  • [29] An electrochemical biosensor based on multi-wall carbon nanotube–modified screen-printed electrode immobilized by uricase for the detection of salivary uric acid
    Weishan Shi
    Jing Li
    Jie Wu
    Qianying Wei
    Cuili Chen
    Ning Bao
    Chunmei Yu
    Haiying Gu
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7275 - 7283
  • [30] Amperometric L-lactate biosensor based on screen-printed carbon electrode containing cobalt phthalocyanine, coated with lactate oxidase-mesoporous silica conjugate layer
    Shimomura, Takeshi
    Sumiya, Touru
    Ono, Masatoshi
    Ito, Tetsuji
    Hanaoka, Taka-aki
    ANALYTICA CHIMICA ACTA, 2012, 714 : 114 - 120