Aortic annulus measurement with computed tomography angiography reduces aortic regurgitation after transfemoral aortic valve replacement compared to 3-D echocardiography: a single-centre experience

被引:6
作者
Wystub, Nadja [1 ]
Baez, Laura [1 ]
Moebius-Winkler, Sven [1 ]
Poerner, Tudor C. [1 ]
Goebel, Bjoern [1 ]
Hamadanchi, Ali [1 ]
Doenst, Torsten [2 ]
Grimm, Julia [3 ]
Lehmkuhl, Lukas [3 ]
Teichgraeber, Ulf [3 ]
Schulze, P. Christian [1 ]
Franz, Marcus [1 ]
机构
[1] Friedrich Schiller Univ Jena, Univ Hosp Jena, Dept Internal Med 1, Div Cardiol Angiol Pneumol & Intens Med Care, Klinikum 1, D-07747 Jena, Germany
[2] Friedrich Schiller Univ Jena, Jena Univ Hosp, Dept Cardiothorac Surg, Jena, Germany
[3] Friedrich Schiller Univ Jena, Jena Univ Hosp, Dept Diagnost & Intervent Radiol, Jena, Germany
关键词
Paravalvular regurgitation; Aortic annulus sizing; Multidetector computed tomography; Three-dimensional transoesophageal echocardiography; Transcatheter aortic valve replacement; PARAVALVULAR REGURGITATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSCATHETER; IMPLANTATION; IMPACT; OUTCOMES; RECOMMENDATIONS; INTERVENTIONS; PREDICTORS; GUIDELINES;
D O I
10.1007/s00392-019-01462-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Accurate assessment of the aortic annulus is crucial for successful transcatheter aortic valve replacement (TAVR), in particular to prevent paravalvular regurgitation (PVR). We compared aortic annular sizing using multidetector computed tomography (MDCT) and three-dimensional transoesophageal echocardiography (3-D TEE) to determine the predictive value of MDCT. Methods and results All patients admitted for transfemoral TAVR [n = 227; 48.9% balloon expandable (Edwards Sapien 3); 51.1% self-expandable (Core Valve, Evolut R)] at our institution from January 2015 until December 2016 were analysed retrospectively. Aortic annular parameters were obtained either by MDCT or 3-D TEE. Additionally, we included a cohort of patients (n = 27) assessed by both MDCT and 3D TEE between October 2017 and April 2018 to enable intra-individual comparison of the two methods. Indications for TAVR were severe degenerative aortic stenosis (AS; 94.7%) or re-stenosis after surgical AVR (5.3%). 74.4% were classified as high-gradient AS. The mean age was 80 (37-94) years and 75.8% presented with NYHA III/IV. STS risk of mortality was intermediate (3.5 +/- 2.3). MDCT and 3-D TEE were performed in 116 and 111 patients for aortic annulus sizing, respectively. Significantly larger implants were chosen in the CT group irrespective of prosthesis type or post-dilatation. Follow-up (median at 79 days) revealed significantly less PVR in the MDCT compared to 3-D TEE group (absence of PVR in 59.3% and 40.7%, p = 0.016), without differences in mortality. Patients without PVR or mild PVR had a better clinical performance according to NYHA class (p = 0.016). Conclusion MDCT is superior to 3-D TEE in terms of sizing accuracy and clinical outcomes. Reduction of PVR after TAVR with MDCT is likely due to valve annulus undersizing by TEE.
引用
收藏
页码:1266 / 1275
页数:10
相关论文
共 34 条
  • [1] Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    Abdel-Wahab, Mohamed
    Zahn, Ralf
    Horack, Martin
    Gerckens, Ulrich
    Schuler, Gerhard
    Sievert, Horst
    Eggebrecht, Holger
    Senges, Jochen
    Richardt, Gert
    [J]. HEART, 2011, 97 (11) : 899 - 906
  • [2] SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Schoenhagen, Paul
    Min, James K.
    Leipsic, Jonathon A.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 366 - 380
  • [3] Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature
    Athappan, Ganesh
    Patvardhan, Eshan
    Tuzcu, E. Murat
    Svensson, Lars Georg
    Lemos, Pedro A.
    Fraccaro, Chiara
    Tarantini, Giuseppe
    Sinning, Jan-Malte
    Nickenig, Georg
    Capodanno, Davide
    Tamburino, Corrado
    Latib, Azeem
    Colombo, Antonio
    Kapadia, Samir R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) : 1585 - 1595
  • [4] Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
  • [5] 3D transoesophageal echocardiography in the TAVI sizing arena: Should we do it and how do we do it?
    Bleakley C.
    Eskandari M.
    Monaghan M.
    [J]. Echo Research & Practice, 2017, 4 (1) : R21 - R32
  • [6] A Practical Guide to Multimodality Imaging of Transcatheter Aortic Valve Replacement
    Bloomfield, Gerald S.
    Gillam, Linda D.
    Hahn, Rebecca T.
    Kapadia, Samir
    Leipsic, Jonathon
    Lerakis, Stamatios
    Tuzcu, Murat
    Douglas, Pamela S.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2012, 5 (04) : 441 - 455
  • [7] Outcomes and Predictors of Mortality After Transcatheter Aortic Valve Implantation: Results of the Brazilian Registry
    de Brito, Fabio S., Jr.
    Carvalho, Luiz A.
    Sarmento-Leite, Rogerio
    Mangione, Jose A.
    Lemos, Pedro
    Siciliano, Alexandre
    Caramori, Paulo
    Thiago, Luiz Sao
    Grube, Eberhard
    Abizaid, Alexandre
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (05) : E153 - E162
  • [8] Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence
    Detaint, Delphine
    Lepage, Laurent
    Himbert, Dominique
    Brochet, Eric
    Messika-Zeitoun, David
    Iung, Bernard
    Vahanian, Alec
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) : 821 - 827
  • [9] Paravalvular regurgitation after conventional aortic and mitral valve replacement: A benchmark for alternative approaches
    Duncan, Brett F.
    McCarthy, Patrick M.
    Kruse, Jane
    Andrei, Adin-Cristian
    Li, Zhi
    Russell, Hyde M.
    Abicht, Travis O.
    Rigolin, Vera H.
    Thomas, James D.
    Davidson, Charles J.
    Bonow, Robert O.
    Malaisrie, S. Chris
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (04) : 860 - 868
  • [10] Location and Severity of Aortic Valve Calcium and Implications for Aortic Regurgitation After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Ng, Arnold C. T.
    Schuijf, Joanne D.
    van der Kley, Frank
    Colli, Andrea
    Palmen, Meindert
    de Weger, Arend
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Delgado, Victoria
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (10) : 1470 - 1477