Resolution Properties of a Calcium Tungstate (CaWO4) Screen Coupled to a CMOS Imaging Detector

被引:6
作者
Koukou, Vaia [1 ]
Martini, Niki [1 ]
Valais, Ioannis [2 ]
Bakas, Athanasios [3 ]
Kalyvas, Nektarios [2 ]
Lavdas, Eleftherios [3 ]
Fountos, George [2 ]
Kandarakis, Ioannis [2 ]
Michail, Christos [2 ]
机构
[1] Univ Patras, Med Sch, Dept Med Phys, Patras 26500, Greece
[2] Technol Educ Inst Athens, Dept Biomed Engn, Radiat Phys Mat Technol & Biomed Imaging Lab, Athens 12210, Greece
[3] Technol Educ Inst Athens, Dept Radiol & Radiat Therapy, Athens 12210, Greece
来源
INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2017) | 2017年 / 931卷
关键词
CaWO4; Medical imaging; CMOS; IEC; MTF; QUANTUM EFFICIENCY DQE; DARK-MATTER-SEARCH; LUMINESCENCE; SCINTILLATORS; PERFORMANCE; MTF;
D O I
10.1088/1742-6596/931/1/012027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the current work was to assess the resolution properties of a calcium tungstate (CaWO4) screen (screen coating thickness: 50.09 mg/cm(2), actual thickness: 167.2 mu m) coupled to a high resolution complementary metal oxide semiconductor (CMOS) digital imaging sensor. A 2.7x3.6 cm(2) CaWO4 sample was extracted from an Agfa Curix universal screen and was coupled directly with the active area of the active pixel sensor (APS) CMOS sensor. Experiments were performed following the new IEC 62220-1-1: 2015 International Standard, using an RQA-5 beam quality. Resolution was assessed in terms of the Modulation Transfer Function (MTF), using the slanted-edge method. The CaWO4/CMOS detector configuration was found with linear response, in the exposure range under investigation. The final MTF was obtained through averaging the oversampled edge spread function (ESF), using a custom-made software developed by our team, according to the IEC 62220-1-1: 2015. Considering the renewed interest in calcium tungstate for various applications, along with the resolution results of this work, CaWO4 could be also considered for use in X-ray imaging devices such as charged-coupled devices (CCD) and CMOS.
引用
收藏
页数:4
相关论文
共 25 条
  • [1] A CMOS active pixel sensor system for laboratory-based x-ray diffraction studies of biological tissue
    Bohndiek, Sarah E.
    Cook, Emily J.
    Arvanitis, Costas D.
    Olivo, Alessandro
    Royle, Gary J.
    Clark, Andy T.
    Prydderch, Mark L.
    Turchetta, Renato
    Speller, Robert D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03) : 655 - 672
  • [2] NEW X-RAY PHOSPHORS
    BRIXNER, LH
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 1987, 16 (3-4) : 253 - 281
  • [3] Measurement of the (Gd,La)2O2S:Tb phosphor efficiency for x-ray imaging applications
    Cavouras, D
    Kandarakis, I
    Nomicos, CD
    Bakas, A
    Panayiotakis, GS
    [J]. RADIATION MEASUREMENTS, 2000, 32 (01) : 5 - 13
  • [4] CMOS APS detector characterization for quantitative X-ray imaging
    Endrizzi, Marco
    Oliva, Piernicola
    Golosio, Bruno
    Delogu, Pasquale
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 703 : 26 - 32
  • [5] A novel easy-to-use phantom for the determination of MTF in SPECT scanners
    Fountos, G. P.
    Michail, C. M.
    Zanglis, A.
    Samartzis, A.
    Martini, N.
    Koukou, V.
    Kalatzis, I.
    Kandarakis, I. S.
    [J]. MEDICAL PHYSICS, 2012, 39 (03) : 1561 - 1570
  • [6] International Electrotechnical Commission, 2015, IEC 62220-1-1
  • [7] Measurement of the X-ray luminescence and spectral compatibility of the CdPO3Cl:Mn phosphor
    Kandarakis, I
    Cavouras, D
    Nomicos, CD
    Panayiotakis, GS
    [J]. RADIATION MEASUREMENTS, 2001, 33 (02) : 217 - 224
  • [8] Detective quantum efficiency (DQE) in PET scanners: A simulation study
    Karpetas, George E.
    Michail, Christos M.
    Fountos, George P.
    Kalyvas, Nektarios I.
    Valais, Ioannis G.
    Kandarakis, Ioannis S.
    Panayiotakis, George S.
    [J]. APPLIED RADIATION AND ISOTOPES, 2017, 125 : 154 - 162
  • [9] A new PET resolution measurement method through Monte-Carlo simulations
    Karpetas, George E.
    Michail, Christos M.
    Fountos, George P.
    Kandarakis, Ioannis S.
    Panayiotakis, George S.
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (09) : 967 - 976
  • [10] Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities
    Konstantinidis, A.
    [J]. INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2015), 2015, 637