Development and validation of a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of β-lactam antibiotic concentration in human plasma

被引:62
作者
Rigo-Bonnin, Raul [1 ]
Ribera, Alba [2 ,3 ]
Arbiol-Roca, Ariadna [1 ]
Cabo-Sacristan, Sara [4 ]
Padulles, Ariadna [4 ]
Murillo, Oscar [2 ,3 ]
Shaw, Evelyn [2 ,3 ]
Granada, Rosa [5 ]
Perez-Fernandez, Xose L. [5 ]
Tubau, Fe [6 ,7 ]
Alia, Pedro [1 ]
机构
[1] Hosp Univ Bellvitge, IDIBELL, Lab Clin Dept, Barcelona, Spain
[2] Hosp Univ Bellvitge, IDIBELL, Infect Dis Dept, Barcelona, Spain
[3] Inst Salud Carlos III, Spanish Network Res Infect Dis REIPI RD12 0012, Madrid, Spain
[4] Hosp Univ Bellvitge, IDIBELL, Pharm Dept, Barcelona, Spain
[5] Hosp Univ Bellvitge, IDIBELL, Intens Care Dept, Barcelona, Spain
[6] Hosp Univ Bellvitge, IDIBELL, Microbiol Dept, Barcelona, Spain
[7] Inst Salud Carlos III, Spanish Network Biomed Res Resp Dis CIBERES CB06, Madrid, Spain
关键词
beta-Lactam antibiotics; Human plasma; Protein precipitation; UHPLC-MS/MS; Therapeutic drug monitoring; HUMAN SERUM; UPLC; QUANTIFICATION; CEPHALOSPORINS; PIPERACILLIN; INFUSION; SOCIETY; HPLC;
D O I
10.1016/j.cca.2017.03.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The administration of beta-lactam antibiotics in continuous infusion could let optimize the pharmacokinetic/pharmacodynamic parameters, especially in the treatment of serious bacterial infections. In this context, and also due to variability in their plasmatic concentrations, therapeutic drug monitoring (TDM) may be useful to optimize dosing and, therefore, be useful for the clinicians. Material and methods: We developed and validated a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of amoxicillin, ampicillin, cloxacillin, piperacillin, cefepime, ceftazidime, cefuroxime, aztreonam and meropenem concentrations in plasma. The chromatographic separation was achieved using an Acquity (R)-UPLC (R) BEH (TM) (2.1 x 100 mm id, 1.7 pm) reverse-phase C-18 column, with a water/acetonitrile linear gradient containing 0.1% formic acid at a 0.4 mL/min flow rate. beta-Lactam antibiotics and their internal standards were detected by electrospray ionization mass spectrometry in multiple reaction monitoring mode. Results: Chromatography run time was 7.0 min and beta-lactam antibiotics eluted at retention times ranging between 1.08 and 1.91 min. The lower limits of quantification were between 0.50 and 1.00 mg/L. Coefficients of variation and relative bias absolute values were <13.3% and 14.7%, respectively. Recovery values ranged from 55.7% to 84.8%. Evaluation of the matrix effect showed ion enhancement for all antibiotics. No interferences or carryover were observed. Conclusions: Our measurement procedure could be applied to daily clinical laboratory practice to measure the concentration of beta lactam antibiotics in plasma, for instance in patients with bone and joint infections and critically ill patients. 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
[31]   Simultaneous quantification of atenolol and chlorthalidone in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry [J].
Shah, Jaivik V. ;
Patel, Daxesh P. ;
Shah, Priyanka A. ;
Sanyal, Mallika ;
Shrivastav, Pranav S. .
BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (02) :208-216
[32]   Simultaneous Determination of Multiclass Pesticides and Antibiotics in Honey Samples Based on Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Débora Orso ;
Luana Floriano ;
Lucila C. Ribeiro ;
Nelson M. G. Bandeira ;
Osmar D. Prestes ;
Renato Zanella .
Food Analytical Methods, 2016, 9 :1638-1653
[33]   Simultaneous Determination of Multiclass Pesticides and Antibiotics in Honey Samples Based on Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Orso, Debora ;
Floriano, Luana ;
Ribeiro, Lucila C. ;
Bandeira, Nelson M. G. ;
Prestes, Osmar D. ;
Zanella, Renato .
FOOD ANALYTICAL METHODS, 2016, 9 (06) :1638-1653
[34]   Development of a new ultra-high performance liquid chromatography-tandem mass spectrometry method for determination of ambroxol hydrochloride in serum with pharmacokinetic application [J].
Vujovic, Maja M. ;
Jokanovic, Milan ;
Nikolic, Goran M. .
HEMIJSKA INDUSTRIJA, 2016, 70 (04) :409-418
[35]   Development and validation of a high-performance liquid chromatography-tandem mass spectrometry assay quantifying olaparib in human plasma [J].
Nijenhuis, C. M. ;
Lucas, L. ;
Rosing, H. ;
Schellens, J. H. M. ;
Beijnen, J. H. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 940 :121-125
[36]   Development and validation of a high-performance liquid chromatography-tandem mass spectrometry assay quantifying vemurafenib in human plasma [J].
Nijenhuis, C. M. ;
Rosing, H. ;
Schellens, J. H. M. ;
Beijnen, J. H. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 :630-635
[37]   Determination of unbound piperaquine in human plasma by ultra-high performance liquid chromatography tandem mass spectrometry [J].
Huang, Liusheng ;
Sok, Vong ;
Aslam-Mir, Usman ;
Marzan, Florence ;
Whalen, Meghan ;
Rosenthal, Philip J. ;
Aweeka, Francesca .
JOURNAL OF CHROMATOGRAPHY OPEN, 2022, 2
[38]   Determination of colistin in animal tissues, egg, milk, and feed by ultra-high performance liquid chromatography-tandem mass spectrometry [J].
Fu, Qin ;
Li, Xiaowei ;
Zheng, Kangni ;
Ke, Yuebin ;
Wang, Yingyu ;
Wang, Lina ;
Yu, Fugen ;
Xia, Xi .
FOOD CHEMISTRY, 2018, 248 :166-172
[39]   Development and validation of amitriptyline and its metabolite in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and its application to a bioequivalence study [J].
Bhatt, Mitesh ;
Shah, Sanjay ;
Shivprakash .
BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (11) :1247-1254
[40]   A reference measurement procedure for amino acids in blood using isotope dilution ultra-performance liquid chromatography-tandem mass spectrometry [J].
Kim, Juok ;
Tran, Thi Thanh Huong ;
Hong, Seon-Pyo ;
Jeong, Ji-Seon .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1055 :72-80