Development and validation of a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of β-lactam antibiotic concentration in human plasma

被引:62
作者
Rigo-Bonnin, Raul [1 ]
Ribera, Alba [2 ,3 ]
Arbiol-Roca, Ariadna [1 ]
Cabo-Sacristan, Sara [4 ]
Padulles, Ariadna [4 ]
Murillo, Oscar [2 ,3 ]
Shaw, Evelyn [2 ,3 ]
Granada, Rosa [5 ]
Perez-Fernandez, Xose L. [5 ]
Tubau, Fe [6 ,7 ]
Alia, Pedro [1 ]
机构
[1] Hosp Univ Bellvitge, IDIBELL, Lab Clin Dept, Barcelona, Spain
[2] Hosp Univ Bellvitge, IDIBELL, Infect Dis Dept, Barcelona, Spain
[3] Inst Salud Carlos III, Spanish Network Res Infect Dis REIPI RD12 0012, Madrid, Spain
[4] Hosp Univ Bellvitge, IDIBELL, Pharm Dept, Barcelona, Spain
[5] Hosp Univ Bellvitge, IDIBELL, Intens Care Dept, Barcelona, Spain
[6] Hosp Univ Bellvitge, IDIBELL, Microbiol Dept, Barcelona, Spain
[7] Inst Salud Carlos III, Spanish Network Biomed Res Resp Dis CIBERES CB06, Madrid, Spain
关键词
beta-Lactam antibiotics; Human plasma; Protein precipitation; UHPLC-MS/MS; Therapeutic drug monitoring; HUMAN SERUM; UPLC; QUANTIFICATION; CEPHALOSPORINS; PIPERACILLIN; INFUSION; SOCIETY; HPLC;
D O I
10.1016/j.cca.2017.03.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The administration of beta-lactam antibiotics in continuous infusion could let optimize the pharmacokinetic/pharmacodynamic parameters, especially in the treatment of serious bacterial infections. In this context, and also due to variability in their plasmatic concentrations, therapeutic drug monitoring (TDM) may be useful to optimize dosing and, therefore, be useful for the clinicians. Material and methods: We developed and validated a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of amoxicillin, ampicillin, cloxacillin, piperacillin, cefepime, ceftazidime, cefuroxime, aztreonam and meropenem concentrations in plasma. The chromatographic separation was achieved using an Acquity (R)-UPLC (R) BEH (TM) (2.1 x 100 mm id, 1.7 pm) reverse-phase C-18 column, with a water/acetonitrile linear gradient containing 0.1% formic acid at a 0.4 mL/min flow rate. beta-Lactam antibiotics and their internal standards were detected by electrospray ionization mass spectrometry in multiple reaction monitoring mode. Results: Chromatography run time was 7.0 min and beta-lactam antibiotics eluted at retention times ranging between 1.08 and 1.91 min. The lower limits of quantification were between 0.50 and 1.00 mg/L. Coefficients of variation and relative bias absolute values were <13.3% and 14.7%, respectively. Recovery values ranged from 55.7% to 84.8%. Evaluation of the matrix effect showed ion enhancement for all antibiotics. No interferences or carryover were observed. Conclusions: Our measurement procedure could be applied to daily clinical laboratory practice to measure the concentration of beta lactam antibiotics in plasma, for instance in patients with bone and joint infections and critically ill patients. 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
[21]   Generic Methods for Simultaneous Analysis of Four Direct Oral Anticoagulants in Human Plasma and Urine by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Ren, Jian-Wei ;
Zheng, Xin ;
Han, Xiao-Hong .
MOLECULES, 2023, 28 (05)
[22]   Buprenorphine and norbuprenorphine quantification in human plasma by simple protein precipitation and ultra-high performance liquid chromatography tandem mass spectrometry [J].
Luethi, Guillaume ;
Blangy, Valeria ;
Eap, Chin B. ;
Ansermot, Nicolas .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 77 :1-8
[23]   Quantification of typical antipsychotics in human plasma by ultra-high performance liquid chromatography tandem mass spectrometry for therapeutic drug monitoring [J].
Gradinaru, Julieta ;
Vullioud, Astrid ;
Eap, Chin B. ;
Ansermot, Nicolas .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 :36-44
[24]   Ultra-high performance liquid chromatography tandem mass-spectrometry for simple and simultaneous quantification of cannabinoids [J].
Jamwal, Rohitash ;
Topletz, Ariel R. ;
Ramratnam, Bharat ;
Akhlaghi, Fatemeh .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1048 :10-18
[25]   An improved method for measurement of testosterone in human plasma and saliva by ultra-performance liquid chromatography-tandem mass spectrometry [J].
Alvi, Syed N. ;
Hammami, Muhammad M. .
JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2020, 11 (02) :64-68
[26]   Determination of mitomycin C in rabbit plasma by ultra-high performance liquid chromatography-tandem mass spectrometry [J].
Tang Yao ;
Zhang Shuangqing ;
Li Xiang ;
Sun Xu ;
Wen Nie ;
Yu Min ;
Peng Lili ;
Li Jinrang ;
Li Zuogang ;
Li Bo .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (02) :154-159
[27]   Simultaneous determination of eight β-lactam antibiotics in human plasma and cerebrospinal fluid by liquid chromatography coupled to tandem mass spectrometry [J].
Bellouard, Ronan ;
Deslandes, Guillaume ;
Morival, Clement ;
Li, Julien ;
Boutoille, David ;
Jolliet, Pascale ;
Dailly, Eric ;
Gregoire, Matthieu .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 178
[28]   Determination of methocarbamol concentration in human plasma by high performance liquid chromatography-tandem mass spectrometry [J].
Zha, Wuyi ;
Zhu, Zhimeng .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (9-10) :831-835
[29]   Rapid Determination of Tetrodotoxin in Human Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Chen Weizhu ;
Zhang Yiping ;
Sun Jipeng ;
Xie Quanling ;
Hong Zhuan ;
Yi Ruizao .
CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2018, 34 (06) :905-911
[30]   Ultra performance liquid chromatography-tandem mass spectrometry for the determination of epirubicin in human plasma [J].
Li, RP ;
Dong, LL ;
Huang, JX .
ANALYTICA CHIMICA ACTA, 2005, 546 (02) :167-173