Development and validation of a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of β-lactam antibiotic concentration in human plasma

被引:60
作者
Rigo-Bonnin, Raul [1 ]
Ribera, Alba [2 ,3 ]
Arbiol-Roca, Ariadna [1 ]
Cabo-Sacristan, Sara [4 ]
Padulles, Ariadna [4 ]
Murillo, Oscar [2 ,3 ]
Shaw, Evelyn [2 ,3 ]
Granada, Rosa [5 ]
Perez-Fernandez, Xose L. [5 ]
Tubau, Fe [6 ,7 ]
Alia, Pedro [1 ]
机构
[1] Hosp Univ Bellvitge, IDIBELL, Lab Clin Dept, Barcelona, Spain
[2] Hosp Univ Bellvitge, IDIBELL, Infect Dis Dept, Barcelona, Spain
[3] Inst Salud Carlos III, Spanish Network Res Infect Dis REIPI RD12 0012, Madrid, Spain
[4] Hosp Univ Bellvitge, IDIBELL, Pharm Dept, Barcelona, Spain
[5] Hosp Univ Bellvitge, IDIBELL, Intens Care Dept, Barcelona, Spain
[6] Hosp Univ Bellvitge, IDIBELL, Microbiol Dept, Barcelona, Spain
[7] Inst Salud Carlos III, Spanish Network Biomed Res Resp Dis CIBERES CB06, Madrid, Spain
关键词
beta-Lactam antibiotics; Human plasma; Protein precipitation; UHPLC-MS/MS; Therapeutic drug monitoring; HUMAN SERUM; UPLC; QUANTIFICATION; CEPHALOSPORINS; PIPERACILLIN; INFUSION; SOCIETY; HPLC;
D O I
10.1016/j.cca.2017.03.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The administration of beta-lactam antibiotics in continuous infusion could let optimize the pharmacokinetic/pharmacodynamic parameters, especially in the treatment of serious bacterial infections. In this context, and also due to variability in their plasmatic concentrations, therapeutic drug monitoring (TDM) may be useful to optimize dosing and, therefore, be useful for the clinicians. Material and methods: We developed and validated a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of amoxicillin, ampicillin, cloxacillin, piperacillin, cefepime, ceftazidime, cefuroxime, aztreonam and meropenem concentrations in plasma. The chromatographic separation was achieved using an Acquity (R)-UPLC (R) BEH (TM) (2.1 x 100 mm id, 1.7 pm) reverse-phase C-18 column, with a water/acetonitrile linear gradient containing 0.1% formic acid at a 0.4 mL/min flow rate. beta-Lactam antibiotics and their internal standards were detected by electrospray ionization mass spectrometry in multiple reaction monitoring mode. Results: Chromatography run time was 7.0 min and beta-lactam antibiotics eluted at retention times ranging between 1.08 and 1.91 min. The lower limits of quantification were between 0.50 and 1.00 mg/L. Coefficients of variation and relative bias absolute values were <13.3% and 14.7%, respectively. Recovery values ranged from 55.7% to 84.8%. Evaluation of the matrix effect showed ion enhancement for all antibiotics. No interferences or carryover were observed. Conclusions: Our measurement procedure could be applied to daily clinical laboratory practice to measure the concentration of beta lactam antibiotics in plasma, for instance in patients with bone and joint infections and critically ill patients. 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
[1]   Simultaneous Measurement of 11 Antibiotics for Use in the Intensive Care Unit by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
Woksepp, Hanna ;
Karlsson, Louise ;
Arlemalm, Andreas ;
Hallgren, Anita ;
Schon, Thomas ;
Carlsson, Bjorn .
THERAPEUTIC DRUG MONITORING, 2022, 44 (02) :308-318
[2]   Measurement of ganciclovir concentration in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry [J].
Rigo-Bonnin, Rauel ;
Padulles, Ariadna ;
Corral-Comesana, Sofia ;
Cerezo, Gema ;
Maria Grinyo, Josep ;
Colom, Helena ;
Alia-Ramos, Pedro ;
Lloberas, Nuria .
CLINICA CHIMICA ACTA, 2014, 427 :58-64
[3]   An Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Simultaneous Determination of 4 β-Lactam Antibiotics, Tazobactam, and Linezolid in Human Plasma Samples [J].
Piestansky, Juraj ;
Cizmarova, Ivana ;
Mikus, Peter ;
Parrak, Vojtech ;
Babiak, Pavel ;
Secnik, Peter ;
Kovac, Andrej .
THERAPEUTIC DRUG MONITORING, 2022, 44 (06) :784-790
[4]   Measurement of meropenem concentration in different human biological fluids by ultra-performance liquid chromatography-tandem mass spectrometry [J].
Rigo-Bonnin, Rauel ;
Juvany-Roig, Roser ;
Leiva-Badosa, Elisabet ;
Sabater-Riera, Joan ;
Perez-Fernandez, Xose L. ;
Cardenas-Campos, Paola ;
Sospedra-Martinez, Enric ;
Colom, Helena ;
Alia, Pedro .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (20) :4997-5007
[5]   Measurement of total and free docetaxel concentration in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry [J].
Rigo-Bonnin, Raul ;
Cobo-Sacristan, Sara ;
Gonzalo-Diego, Nuria ;
Colom, Helena ;
Munoz-Sanchez, Carmen ;
Urruticoechea, Ander ;
Falo, Catalina ;
Alia, Pedro .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 117 :140-149
[6]   Development and validation of an ultra-high performance liquid chromatography with tandem mass spectrometry method for the simultaneous quantification of direct oral anticoagulants in human plasma [J].
Zhang, Yu-Fei ;
Liu, Xiao-Qin ;
Wang, Yang ;
Xu, Xin ;
Zhong, Ming-Kang ;
Zhang, Pu ;
Ma, Chun-Lai .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1182
[7]   Liquid chromatography-tandem mass spectrometry for the simultaneous quantitation of enmetazobactam and cefepime in human plasma [J].
Mameli, M. ;
Vezzelli, A. ;
Verze', S. ;
Biondi, S. ;
Motta, P. ;
Greco, A. ;
Michi, M. ;
Breda, M. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 :655-662
[8]   Development and validation of an ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of daptomycin in human plasma [J].
Bazoti, Fotini N. ;
Gikas, Evangelos ;
Skoutelis, Athanasios ;
Tsarbopoulos, Anthony .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) :78-85
[9]   Development, validation, and application of an ultra-high performance liquid chromatography-tandem mass spectrometry method for the estimation of Ropanicant in human plasma and urine [J].
Nirogi, Ramakrishna ;
Kalaikadhiban, Ilayaraja ;
Rayapati, Lakshmi Prasanna ;
Pantangi, Hanumanth Rao ;
Chunduru, Prathyusha ;
Jetta, Satish ;
Jubre, Avinash ;
Mohammed, Abdul Rasheed .
JOURNAL OF CHROMATOGRAPHY OPEN, 2023, 3
[10]   Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine [J].
Fraselle, S. ;
De Cremer, K. ;
Coucke, W. ;
Glorieux, G. ;
Vanmassenhove, J. ;
Schepers, E. ;
Neirynck, N. ;
Van Overmeire, I. ;
Van Loco, J. ;
Van Biesen, W. ;
Vanholder, R. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 988 :88-97