Method for isotope ratio drift correction by internal amplifier signal synchronization in MC-ICPMS transient signals

被引:30
作者
Gourgiotis, Alkiviadis [1 ]
Berail, Sylvain [2 ]
Louvat, Pascale [1 ]
Isnard, Helene [3 ]
Moureau, Julien [1 ]
Nonell, Anthony [3 ]
Manhes, Gerard [1 ]
Birck, Jean-Louis [1 ]
Gaillardet, Jerome [1 ]
Pecheyran, Christophe [2 ]
Chartier, Frederic [4 ]
Donard, Olivier F. X. [2 ]
机构
[1] Univ Paris Diderot, Sorbonne Paris Cite, Inst Phys Globe Paris, UMR CNRS 7154, F-75238 Paris, France
[2] Univ Pau & Pays Adour, Lab Chim Analyt Bioinorgan & Environm IPREM UMR 5, F-64053 Pau 9, France
[3] CEA, DEN DPC SEARS LANIE, F-91191 Gif Sur Yvette, France
[4] CEA, DEN DPC, F-91191 Gif Sur Yvette, France
关键词
PLASMA-MASS SPECTROMETRY; PRECISION; MS; FRACTIONATION; SEPARATION; INJECTION; STRONTIUM;
D O I
10.1039/c4ja00118d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of isotope ratios by Multi Collection Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) in transient signals often shows a drift of the isotope signal ratio during signal acquisition. This "isotopic drift" is generally related to the small and distinct time lags between the responses of the amplifiers involved in the Faraday detector configuration. In this work, a method of synchronization of transient isotope signals for a duration of a few tens of seconds is proposed in order to (1) quantify the time lags between the amplifiers using the ratios of the raw isotope signals and (2) correct the isotope ratio drifts. The method was successfully tested on lead isotope ratio measurements obtained from two different multi-collector mass spectrometers and setups (flow injection with direct injection and gas chromatography). This approach offered a precise determination of the time lag between the different amplifier systems and an effective correction of the isotope ratio drift. The performances of the methods traditionally used for isotope ratio calculation of transient signals were also compared before and after isotope ratio drift correction.
引用
收藏
页码:1607 / 1617
页数:11
相关论文
共 27 条
[11]   Measurement of plutonium isotope ratios in nuclear fuel samples by HPLC-MC-ICP-MS [J].
Günther-Leopold, I ;
Waldis, JK ;
Wernli, B ;
Kopajtic, Z .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) :197-202
[12]   Measurement of isotope ratios on transient signals by MC-ICP-MS [J].
Günther-Leopold, I ;
Wernli, B ;
Kopajtic, Z ;
Günther, D .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :241-249
[13]   Improvements in precision of isotopic ratio measurements using laser ablation-multiple collector-ICP-mass spectrometry: reduction of changes in measured isotopic ratios [J].
Hirata, T ;
Hayano, Y ;
Ohno, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1283-1288
[14]  
Hirata T., 2012, ISOTOPIC ANAL, P93, DOI 10.1002/9783527650484.ch4
[15]   Chlorine isotope fractionation of a semi-volatile organochlorine compound during preparative megabore-column capillary gas chromatography [J].
Holmstrand, H ;
Mandalakis, M ;
Zencak, Z ;
Gustafsson, Ö ;
Andersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (01) :133-138
[16]   Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS [J].
Kappel, S. ;
Boulyga, S. F. ;
Dorta, L. ;
Guenther, D. ;
Hattendorf, B. ;
Koffler, D. ;
Laaha, G. ;
Leisch, F. ;
Prohaska, T. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (09) :2943-2955
[17]   Review of the State-of-the-Art of Laser Ablation Inductively Coupled Plasma Mass Spectrometry [J].
Koch, Joachim ;
Guenther, Detlef .
APPLIED SPECTROSCOPY, 2011, 65 (05) :155A-162A
[18]   Isotope ratios on transient signals with GC-MC-ICP-MS [J].
Krupp, EA ;
Donard, OFX .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) :233-242
[19]   Precise isotope-ratio determination by CGC hyphenated to ICP-MCMS for speciation of trace amounts of gaseous sulfur, with SF6 as example compound [J].
Krupp, EM ;
Pécheyran, C ;
Meffan-Main, S ;
Donard, OFX .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :250-255
[20]   MC-ICP-MS Isotope Measurements with Direct Injection Nebulisation (d-DIHEN): Optimisation and Application to Boron in Seawater and Carbonate Samples [J].
Louvat, Pascale ;
Bouchez, Julien ;
Paris, Guillaume .
GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2011, 35 (01) :75-88