Method for isotope ratio drift correction by internal amplifier signal synchronization in MC-ICPMS transient signals

被引:30
作者
Gourgiotis, Alkiviadis [1 ]
Berail, Sylvain [2 ]
Louvat, Pascale [1 ]
Isnard, Helene [3 ]
Moureau, Julien [1 ]
Nonell, Anthony [3 ]
Manhes, Gerard [1 ]
Birck, Jean-Louis [1 ]
Gaillardet, Jerome [1 ]
Pecheyran, Christophe [2 ]
Chartier, Frederic [4 ]
Donard, Olivier F. X. [2 ]
机构
[1] Univ Paris Diderot, Sorbonne Paris Cite, Inst Phys Globe Paris, UMR CNRS 7154, F-75238 Paris, France
[2] Univ Pau & Pays Adour, Lab Chim Analyt Bioinorgan & Environm IPREM UMR 5, F-64053 Pau 9, France
[3] CEA, DEN DPC SEARS LANIE, F-91191 Gif Sur Yvette, France
[4] CEA, DEN DPC, F-91191 Gif Sur Yvette, France
关键词
PLASMA-MASS SPECTROMETRY; PRECISION; MS; FRACTIONATION; SEPARATION; INJECTION; STRONTIUM;
D O I
10.1039/c4ja00118d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of isotope ratios by Multi Collection Inductively Coupled Plasma Mass Spectrometry (MC-ICPMS) in transient signals often shows a drift of the isotope signal ratio during signal acquisition. This "isotopic drift" is generally related to the small and distinct time lags between the responses of the amplifiers involved in the Faraday detector configuration. In this work, a method of synchronization of transient isotope signals for a duration of a few tens of seconds is proposed in order to (1) quantify the time lags between the amplifiers using the ratios of the raw isotope signals and (2) correct the isotope ratio drifts. The method was successfully tested on lead isotope ratio measurements obtained from two different multi-collector mass spectrometers and setups (flow injection with direct injection and gas chromatography). This approach offered a precise determination of the time lag between the different amplifier systems and an effective correction of the isotope ratio drift. The performances of the methods traditionally used for isotope ratio calculation of transient signals were also compared before and after isotope ratio drift correction.
引用
收藏
页码:1607 / 1617
页数:11
相关论文
共 27 条
[1]  
[Anonymous], 30249 THERM FISH SCI
[2]   Reevaluation of precise lead isotope measurements by thermal ionization mass spectrometry:: comparison with determinations by plasma source mass spectrometry [J].
Doucelance, R ;
Manhès, G .
CHEMICAL GEOLOGY, 2001, 176 (1-4) :361-377
[3]   ABSOLUTE ISOTOPIC ABUNDANCE AND THE ATOMIC WEIGHT OF A REFERENCE SAMPLE OF THALLIUM [J].
DUNSTAN, LP ;
GRAMLICH, JW ;
BARNES, IL ;
PURDY, WC .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1980, 85 (01) :1-10
[4]   Determination of compound-specific Hg isotope ratios from transient signals using gas chromatography coupled to multicollector inductively coupled plasma mass spectrometry (MC-ICP/MS) [J].
Dzurko, Mark ;
Foucher, Delphine ;
Hintelmann, Holger .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) :345-355
[5]   Simultaneous determination of species-specific isotopic composition of Hg by gas chromatography coupled to multicollector ICPMS [J].
Epov, Vladimir N. ;
Rodriguez-Gonzalez, Pablo ;
Sonke, Jeroen E. ;
Tessier, Emmanuel ;
Amouroux, David ;
Maurice Bourgoin, Laurence ;
Donard, Olivier F. X. .
ANALYTICAL CHEMISTRY, 2008, 80 (10) :3530-3538
[6]   Approach to Measure Isotopic Ratios in Species Using Multicollector-ICPMS Coupled with Chromatography [J].
Epov, Vladimir N. ;
Berail, Sylvain ;
Jimenez-Moreno, Maria ;
Perrot, Vincent ;
Pecheyran, Christophe ;
Amouroux, David ;
Donard, Olivier F. X. .
ANALYTICAL CHEMISTRY, 2010, 82 (13) :5652-5662
[7]   Measurement of high precision isotope ratios for mercury from coals using transient signals [J].
Evans, RD ;
Hintelmann, H ;
Dillon, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :1064-1069
[8]   An alternative data acquisition and evaluation strategy for improved isotope ratio precision using LA-MC-ICP-MS applied to stable and radiogenic strontium isotopes in carbonates [J].
Fietzke, J. ;
Liebetrau, V. ;
Guenther, D. ;
Guers, K. ;
Hametner, K. ;
Zumholz, K. ;
Hansteen, T. H. ;
Eisenhauer, A. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (07) :955-961
[9]   Large volume injection in ion chromatography separation of rubidium and strontium for on-line inductively coupled plasma mass spectrometry determination of strontium isotope ratios [J].
Garcia-Ruiz, Silvia ;
Moldovan, Mariella ;
Garcia Alonso, J. Ignacio .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1149 (02) :274-281
[10]  
Gueguen F., 2013, GOLDSCH C FLOR IT