Exergy Analysis: a Three-heat-source (Air, Wastewater & Energy Recycle) Hot Water System

被引:0
|
作者
Zhang, Zhongbin [1 ]
Huang, Hu [1 ]
Yang, Dongdong
Yu, Jia [1 ]
Chen, Zemin
机构
[1] Nanjing Normal Univ, Sch Dynam Engn, Nanjing, Peoples R China
来源
6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS | 2009年
关键词
Three-heat-source hot-water system; Exergy analysis; Thermal calculation; energy-saving; HEAT-PUMP SYSTEMS;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, comparison on air-source heat pump hot water system (ASHP), groundwater source heat pump hot water system (GSHP) and three-heat-source hot-water system (TSHS) were analyzed. The TSHS operates with ASHP running with valley electricity during night, waste heat of bath recycled during afternoon, and wastewater-source heat pump hot water system (WSHP) running with peak electricity. Based on the meteorological parameter condition in Nanjing, environmental temperatures for ASHP were chosen as 35 degrees C, 20 degrees C, 7 degrees C and -6 degrees C respectively, for GSHP, 18 degrees C, for WSHP, 30 degrees C. Other data for these three systems are made the same: fresh water for bath at 45 degrees C, condensing temperature t(k)=58 degrees C, evaporating temperature to be confirmed according to environmental temperature, superheat degree SH-10 degrees C, super cooling degree SC-5 degrees C, isentropic efficiency of compressor eta(i)=0.75. Based on the above condition, thermodynamic calculation and exergy analysis were made on these three systems. Results indicate that: work condition of ASHP varies considerably, while those of GSHP and WSHP are steady on the whole. Annual average exergy efficiency of ASHP (13.82%), which increases accordingly with the increase of high temperature runtime (17.92% maximum), is the weighted average of exergy efficiencies in four environments. The annual average exergy efficiency of GSHP is 15.36% and that of WSHP is 23.97%. The annual average exergy efficiency of TSHS, determined by the rate of the runtime of ASHP and WSHP, which should be calculated with the cost of valley and peak electricity considered, varies between 13.82% and 23.97%. As is shown in the conclusion, TSHS is well worth popularization for it runs at a steady course with low cost and high efficiency, especially for schools which do not need hot water system during the time at the highest and lowest temperature.
引用
收藏
页码:1514 / 1520
页数:7
相关论文
共 50 条
  • [41] Exergy performance analysis of the conceptual district energy network system with heat pump
    Shin, Seungwon
    Chung, Haseung
    Kim, Minsung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (08) : 3325 - 3333
  • [42] Exergy performance analysis of the conceptual district energy network system with heat pump
    Seungwon Shin
    Haseung Chung
    Minsung Kim
    Journal of Mechanical Science and Technology, 2014, 28 : 3325 - 3333
  • [43] Exergy Analysis of Biogas Engine-driven Heat Pump System for Wastewater Treatment Plant
    Li, Xiaoming
    Wu, Haoyu
    Wang, Zhiyao
    Shi, Yue
    2011 3RD WORLD CONGRESS IN APPLIED COMPUTING, COMPUTER SCIENCE, AND COMPUTER ENGINEERING (ACC 2011), VOL 4, 2011, 4 : 166 - 172
  • [44] Exergy analysis of a thermostatic heat pump drying system with adjustable bypass air ratios
    Qin, Qiuyuan
    Tang, Lan
    INTERNATIONAL JOURNAL OF EXERGY, 2021, 35 (01) : 155 - 171
  • [45] Energy and exergy analysis of a ground source heat pump system for a public building in Wuhan, China under different control strategies
    Hu, Pingfang
    Hu, Qiushi
    Lin, Yaolin
    Yang, Wei
    Xing, Lu
    ENERGY AND BUILDINGS, 2017, 152 : 301 - 312
  • [46] Long-term energy and exergy analysis of heat pumps with different types of ground and air heat exchangers
    Habibi, Mohammad
    Hakkaki-Fard, Ali
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 414 - 433
  • [47] Influence of the water tank size and air source heat pump size on the energy saving potential of the energy storage heating system
    Lyu, Weihua
    Wang, Zhichao
    Li, Xiaofeng
    Deng, Gaofeng
    Xu, Zhaowei
    Li, Hao
    Yang, Yingxia
    Zhan, Binfei
    Zhao, Mingyang
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [48] Energy, exergy and exergoeconomic evaluation of the air source transcritical CO2 heat pump with internal heat exchanger for space heating
    Wang, Yikai
    Ye, Zuliang
    Yin, Xiang
    Song, Yulong
    Cao, Feng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 130 : 14 - 26
  • [49] Exergy analysis of a one-stage adiabatic compressed air energy storage system
    Mozayeni, Hamidreza
    Wang, Xiaolin
    Negnevitsky, Michael
    2ND INTERNATIONAL CONFERENCE ON ENERGY AND POWER (ICEP2018), 2019, 160 : 260 - 267
  • [50] Thermodynamic analytical solution and exergy analysis for supercritical compressed air energy storage system
    Guo, Huan
    Xu, Yujie
    Chen, Haisheng
    Guo, Cong
    Qin, Wei
    APPLIED ENERGY, 2017, 199 : 96 - 106