Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients

被引:68
作者
Haverich, Axel [1 ]
Wahlers, Thorsten C. [2 ]
Borger, Michael A. [3 ]
Shrestha, Malakh [1 ]
Kocher, Alfred A. [4 ]
Walther, Thomas [5 ]
Roth, Matthias [5 ]
Misfeld, Martin [3 ]
Mohr, Friedrich W. [3 ]
Kempfert, Joerg [5 ]
Dohmen, Pascal M. [6 ]
Schmitz, Christoph [7 ]
Rahmanian, Parwis [2 ]
Wiedemann, Dominik [4 ]
Duhay, Francis G. [8 ]
Laufer, Guenther [4 ]
机构
[1] Hannover Med Sch, Hannover, Germany
[2] Med Univ Cologne, Cologne, Germany
[3] Heart Ctr Leipzig, Leipzig, Germany
[4] Med Univ Vienna, Vienna, Austria
[5] Max Planck Inst Physiol & Clin Res, Kerckhoff Klin, Bad Nauheim, Germany
[6] Univ Leipzig, D-04109 Leipzig, Germany
[7] Univ Munich, Munich, Germany
[8] Edwards Lifesci LLC, Irvine, CA USA
关键词
LONG-TERM SURVIVAL; IMPACT; OUTCOMES; TRANSCATHETER; POSITION; STENOSIS;
D O I
10.1016/j.jtcvs.2014.07.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. Methods: In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. Results: The mean patient age was 75.7 +/- 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% (P < .0001) and at 3 years by 16% (P < .0001) compared with at discharge. The prevalence of severe patient-prosthesis mismatch was 3% at discharge and remained stable during the follow-up period. Conclusions: In a large series of elderly patients with symptomatic severe aortic stenosis, rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status.
引用
收藏
页码:2854 / 2860
页数:7
相关论文
共 19 条
[11]   Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement [J].
Kodali, Susheel K. ;
Williams, Mathew R. ;
Smith, Craig R. ;
Svensson, Lars G. ;
Webb, John G. ;
Makkar, Raj R. ;
Fontana, Gregory P. ;
Dewey, Todd M. ;
Thourani, Vinod H. ;
Pichard, Augusto D. ;
Fischbein, Michael ;
Szeto, Wilson Y. ;
Lim, Scott ;
Greason, Kevin L. ;
Teirstein, Paul S. ;
Malaisrie, S. Chris ;
Douglas, Pamela S. ;
Hahn, Rebecca T. ;
Whisenant, Brian ;
Zajarias, Alan ;
Wang, Duolao ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1686-1695
[12]   Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis [J].
Martens, Sven ;
Sadowski, Jerzy ;
Eckstein, Friedrich S. ;
Bartus, Krzysztof ;
Kapelak, Boguslaw ;
Sievers, Hans-Hinrich ;
Schlensak, Christian ;
Carrel, Thierry ;
Suwalski, P. ;
Alfieri, O. ;
Myken, P. ;
Bogers, A. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (03) :749-755
[13]   Late Outcomes for Aortic Valve Replacement With the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-Year Follow-Up in 1,000 Patients [J].
McClure, R. Scott ;
Narayanasamy, Narendren ;
Wiegerinck, Esther ;
Lipsitz, Stuart ;
Maloney, Ann ;
Byrne, John G. ;
Aranki, Sary F. ;
Couper, Gregory S. ;
Cohn, Lawrence H. .
ANNALS OF THORACIC SURGERY, 2010, 89 (05) :1410-1416
[14]   Impact of Prosthesis-Patient Mismatch on Long-Term Survival After Aortic Valve Replacement Influence of Age, Obesity, and Left Ventricular Dysfunction [J].
Mohty, Dania ;
Dumesnil, Jean G. ;
Echahidi, Najmeddine ;
Mathieu, Patrick ;
Dagenais, Francois ;
Voisine, Pierre ;
Pibarot, Philippe .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (01) :39-47
[15]   Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention [J].
Pibarot, P ;
Dumesnil, JG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1131-1141
[16]   Prosthetic Heart Valves Selection of the Optimal Prosthesis and Long-Term Management [J].
Pibarot, Philippe ;
Dumesnil, Jean G. .
CIRCULATION, 2009, 119 (07) :1034-1048
[17]   PROBLEM OF VALVE PROSTHESIS PATIENT MISMATCH [J].
RAHIMTOOLA, SH .
CIRCULATION, 1978, 58 (01) :20-24
[18]   Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: Effect on survival, freedom from heart failure, and left ventricular mass regression [J].
Ruel, M ;
Al-Faleh, H ;
Kulik, A ;
Chan, KL ;
Mesana, TG ;
Burwash, IG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05) :1036-1044
[19]   Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement [J].
Tasca, G ;
Brunelli, F ;
Cirillo, M ;
DallaTomba, M ;
Mhagna, Z ;
Troise, G ;
Quaini, E .
ANNALS OF THORACIC SURGERY, 2005, 79 (02) :505-510