Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients

被引:68
作者
Haverich, Axel [1 ]
Wahlers, Thorsten C. [2 ]
Borger, Michael A. [3 ]
Shrestha, Malakh [1 ]
Kocher, Alfred A. [4 ]
Walther, Thomas [5 ]
Roth, Matthias [5 ]
Misfeld, Martin [3 ]
Mohr, Friedrich W. [3 ]
Kempfert, Joerg [5 ]
Dohmen, Pascal M. [6 ]
Schmitz, Christoph [7 ]
Rahmanian, Parwis [2 ]
Wiedemann, Dominik [4 ]
Duhay, Francis G. [8 ]
Laufer, Guenther [4 ]
机构
[1] Hannover Med Sch, Hannover, Germany
[2] Med Univ Cologne, Cologne, Germany
[3] Heart Ctr Leipzig, Leipzig, Germany
[4] Med Univ Vienna, Vienna, Austria
[5] Max Planck Inst Physiol & Clin Res, Kerckhoff Klin, Bad Nauheim, Germany
[6] Univ Leipzig, D-04109 Leipzig, Germany
[7] Univ Munich, Munich, Germany
[8] Edwards Lifesci LLC, Irvine, CA USA
关键词
LONG-TERM SURVIVAL; IMPACT; OUTCOMES; TRANSCATHETER; POSITION; STENOSIS;
D O I
10.1016/j.jtcvs.2014.07.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. Methods: In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. Results: The mean patient age was 75.7 +/- 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% (P < .0001) and at 3 years by 16% (P < .0001) compared with at discharge. The prevalence of severe patient-prosthesis mismatch was 3% at discharge and remained stable during the follow-up period. Conclusions: In a large series of elderly patients with symptomatic severe aortic stenosis, rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status.
引用
收藏
页码:2854 / 2860
页数:7
相关论文
共 19 条
[1]   Echocardiographic Assessment of Valve Stenosis: EAE/ASE Recommendations for Clinical Practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) :1-23
[2]   Cardiac Surgery in Germany during 2012: A Report on Behalf of the German Society for Thoracic and Cardiovascular Surgery [J].
Beckmann, Andreas ;
Funkat, Anne-Kathrin ;
Lewandowski, Jana ;
Frie, Michael ;
Schiller, Wolfgang ;
Hekmat, Khosro ;
Gummert, Jan F. ;
Mohr, Friedrich Wilhelm .
THORACIC AND CARDIOVASCULAR SURGEON, 2014, 62 (01) :5-17
[3]   Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement [J].
Bleiziffer, S. ;
Eichinger, W. B. ;
Hettich, I. ;
Ruzicka, D. ;
Wottke, M. ;
Bauernschmitt, R. ;
Lange, R. .
HEART, 2008, 94 (05) :637-641
[4]   Current trends in aortic valve replacement: development of the rapid deployment EDWARDS INTUITY valve system [J].
Borger, Michael A. ;
Dohmen, Pascal ;
Misfeld, Martin ;
Mohr, Friedrich W. .
EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (04) :461-470
[5]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[6]   Sutureless Perceval Aortic Valve Replacement: Results of Two European Centers [J].
Folliguet, Thierry A. ;
Laborde, Francois ;
Zannis, Konstantinos ;
Ghorayeb, Gabriel ;
Haverich, Axel ;
Shrestha, Malakh .
ANNALS OF THORACIC SURGERY, 2012, 93 (05) :1483-1488
[7]   Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience [J].
Forcillo, Jessica ;
Pellerin, Michel ;
Perrault, Louis P. ;
Cartier, Raymond ;
Bouchar, Denis ;
Demers, Philippe ;
Carrier, Michel .
ANNALS OF THORACIC SURGERY, 2013, 96 (02) :486-493
[8]   Comparison of Transcatheter and Surgical Aortic Valve Replacement in Severe Aortic Stenosis [J].
Hahn, Rebecca T. ;
Pibarot, Philippe ;
Stewart, William J. ;
Weissman, Neil J. ;
Gopalakrishnan, Deepika ;
Keane, Martin G. ;
Anwaruddin, Saif ;
Wang, Zuyue ;
Bilsker, Martin ;
Lindman, Brian R. ;
Herrmann, Howard C. ;
Kodali, Susheel K. ;
Makkar, Raj ;
Thourani, Vinod H. ;
Svensson, Lars G. ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. ;
Douglas, Pamela S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (25) :2514-2521
[9]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529
[10]   One-year outcomes of the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial: A prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve System [J].
Kocher, Alfred A. ;
Laufer, Guenther ;
Haverich, Axel ;
Shrestha, Malakh ;
Walther, Thomas ;
Misfeld, Martin ;
Kempfert, Joerg ;
Gillam, Linda ;
Schmitz, Christoph ;
Wahlers, Thorsten C. ;
Wippermann, Jens ;
Mohr, Friedrich W. ;
Roth, Matthias ;
Skwara, Adalbert ;
Rahmanian, Parwis ;
Wiedemann, Dominik ;
Borger, Michael A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) :110-116