Construction and Performance Characteristics of Modified Screen Printed and Modified Carbon Paste Sensors for Selective Determination of Cu(II) Ion in Different Polluted Water Samples

被引:20
作者
Ali, Tamer Awad [1 ]
Mohamed, Gehad G. [2 ]
Said, Amal H. [2 ]
机构
[1] EPRI, Dept Anal & Evaluat, Cairo 11727, Egypt
[2] Cairo Univ, Fac Sci, Dept Chem, Giza, Egypt
关键词
Copper determination; Modified carbon paste sensors; Modified screen-printed sensors; N; N '-bis(salicylaldehyde)-p-phenylene diamine ionophore; CHEMICALLY-MODIFIED ELECTRODE; POTENTIOMETRIC DETERMINATION; VOLTAMMETRIC DETERMINATION; GOLD-NANOPARTICLES; COPPER(II) IONS; BROMIDE; COBALT; THIOHYDRAZONE; SURFACTANT; COMPLEXES;
D O I
10.1080/00986445.2015.1088438
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Four new ion-selective electrodes (ISEs), based on N,N-bis(salicylaldehyde)-p-phenylene diamine (SPD) as ionophore, are constructed for the determination of copper(II) ion. The modified carbon paste (MCPEs; electrodes I and II) and modified screen-printed sensors (MSPEs; electrodes III and IV) exhibit good potentiometric response for Cu(II) over a wide concentration range of 1.0x10(-6)-1.0x10(-2)molL(-1) for electrodes (I and II) and 4.8x10(-7)-1.0x10(-2)molL(-1) for electrodes (III and IV) with a detection limit of 1.0x10(-6)molL(-1) for electrodes (I and II) and 4.8x10(-7)molL(-1) for electrodes (III and IV), respectively. The slopes of the calibration graphs are 29.62 +/- 0.9 and 30.12 +/- 0.7mV decade(-1) for electrode (I) (tricresylphosphate (TCP) plasticizer) and electrode (II) (o-nitrophenyloctylether o-NPOE plasticizer), respectively. Also, the MSPEs showed good potentiometric slopes of 29.91 +/- 0.5 and 30.70 +/- 0.3mV decade(-1) for electrode (III) (TCP plasticizer) and electrode (IV) (o-NPOE plasticizer), respectively. The electrodes showed stable and reproducible potentials over a period of 60, 88, 120, and 145 days at the pH range from 3 to 7 for electrodes (II), (III), and (IV) and pH range from 3 to 6 for electrode (I). This method was successfully applied for potentiometric determination of Cu(II) in tap water, river, and formation water samples in addition to pharmaceutical preparation. The results obtained agree with those obtained with the atomic absorption spectrometry (AAS).
引用
收藏
页码:724 / 735
页数:12
相关论文
共 56 条
[1]   Cadmium, lead, copper and manganese determination in human deciduous teeth by electrothermal atomic absorption spectrometry using a lanthanum, palladium and citric acid mixture as chemical modifier [J].
Acar, Orhan ;
Ilim, Murat ;
Kilic, Ziya ;
Turker, Rehber .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (12) :869-878
[2]  
Ali TA, 2015, ANAL METHODS-UK, V7, P6280, DOI [10.1039/c5ay01086a, 10.1039/C5AY01086A]
[3]   Potentiometric determination of La(III) in polluted water samples using modified screen-printed electrode by self-assembled mercapto compound on silver nanoparticles [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 :542-550
[4]  
Ali TA, 2014, INT J ELECTROCHEM SC, V9, P4932
[5]   Determination of Mn(II) ion by a modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) in different water samples [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 :699-707
[6]   Zinc(II) modified carbon paste electrodes based on self-assembled mercapto compounds-gold-nanoparticles for its determination in water samples [J].
Ali, Tamer Awad ;
Azzam, E. M. S. ;
Hegazy, M. A. ;
El-Farargy, A. F. M. ;
Abd-elaal, Ali A. .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (05) :3320-3328
[7]  
Ali TA, 2014, INT J ELECTROCHEM SC, V9, P4158
[8]   Potentiometric determination of iron in polluted water samples using new modified Fe(III)-screen printed ion selective electrode [J].
Ali, Tamer Awad ;
Farag, Ahmed A. ;
Mohamed, Gehad G. .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (04) :2394-2400
[9]   A New Screen-printed Ion Selective Electrode for Determination of Citalopram Hydrobromide in Pharmaceutical Formulation [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. ;
Al-Sabagh, A. M. ;
Migahed, M. A. .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (04) :565-572
[10]  
Ali TA, 2014, INT J ELECTROCHEM SC, V9, P2420