A 32-Channel Lattice Transmission Line Array for Parallel Transmit and Receive MRI at 7 Tesla

被引:79
作者
Adriany, Gregor [1 ]
Auerbach, Edward J. [1 ]
Snyder, Carl J. [1 ]
Gozubuyuk, Ark [1 ]
Moeller, Steen [1 ]
Ritter, Johannes [1 ]
Van de Moortele, Pierre-Francois [1 ]
Vaughan, Tommy [1 ]
Ugurbil, Kamil [1 ]
机构
[1] Univ Minnesota, Sch Med, Dept Radiol, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
RF coil design; transmit array; concentric coils; 7T; transmission line coils; high field; TO-NOISE RATIO; IMAGING PERFORMANCE; PHASED-ARRAY; STEADY-STATE; HUMAN BRAIN; FIELD; COIL; NMR; POWER;
D O I
10.1002/mrm.22413
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1)(+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imaging performance and SNR. Concentric coil arrangements hold promise for developing transceiver arrays incorporating large numbers of coil elements. At magnetic field strengths of 7 tesla and higher where the Larmor frequencies of interest can exceed 300 MHz, the coil array design must also overcome the problem of the coil conductor length approaching the RF wavelength. In this study, a novel concentric arrangement of resonance elements built from capacitively-shortened half-wavelength transmission lines is presented. This approach was utilized to construct an array with whole-brain coverage using 16 transceiver elements and 16 receive-only elements, resulting in a coil with a total of 16 transmit and 32 receive channels. Magn Reson Med 63:1478-1485,2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1478 / 1485
页数:8
相关论文
共 24 条
  • [1] Transmit and receive transmission line arrays for 7 tesla parallel imaging
    Adriany, G
    Van de Moortele, PF
    Wiesinger, F
    Moeller, S
    Strupp, JP
    Andersen, P
    Snyder, C
    Zhang, XL
    Chen, W
    Pruessmann, KP
    Boesiger, P
    Vaughan, T
    Ugurbil, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 434 - 445
  • [2] A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla
    Adriany, Gregor
    De Moortele, Pierre-Francois Van
    Ritter, Johannes
    Moeller, Steen
    Auerbach, Edward J.
    Akguen, Can
    Snyder, Carl J.
    Vaughan, Thomas
    Ugurbill, Kamil
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 590 - 597
  • [3] [Anonymous], [No title captured], Patent No. 6633161
  • [4] [Anonymous], 2007, Proc Intl Soc Mag Reson Med
  • [5] THE FIELD-DEPENDENCE OF NMR IMAGING .1. LABORATORY ASSESSMENT OF SIGNAL-TO-NOISE RATIO AND POWER DEPOSITION
    CHEN, CN
    SANK, VJ
    COHEN, SM
    HOULT, DI
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (05) : 722 - 729
  • [6] Gruetter R, 1998, J NEUROCHEM, V70, P397
  • [7] Jevtic J., 2001, P INT SOC MAGNETIC R, V1, P17
  • [8] ELECTROMAGNETIC-FIELDS OF SURFACE COIL INVIVO NMR AT HIGH-FREQUENCIES
    KELTNER, JR
    CARLSON, JW
    ROOS, MS
    WONG, STS
    WONG, TL
    BUDINGER, TF
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) : 467 - 480
  • [9] Optimizing the intrinsic signal-to-noise ratio of MRI strip detectors
    Kumar, Ananda
    Bottomley, Paul A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 157 - 166
  • [10] Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements
    Metzger, Gregory J.
    Snyder, Carl
    Akgun, Can
    Vaughan, Tommy
    Ugurbil, Kamil
    de Moortele, Pierre-Francois Van
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 396 - 409